3.6.6.1Requirements for installation in Massachusetts

Attention residents of the Commonwealth of Massachusetts:

In the Commonwealth of Massachusetts the following regulation went into effect on 12/30/2005:

(a)For all side wall horizontally vented gas fueled equipment installed in every dwelling, building or structure used in whole or in part for residential purposes, including those owned or operated by the Commonwealth and where the side wall exhaust vent termination is less than seven (7) feet above finished grade in the area of the venting, including but not limited to decks and porches, the following requirements shall be satisfied:

1.INSTALLATION OF CARBON MONOXIDE DETECTORS. At the time of installation of the side wall horizontal vented gas fueled equipment, the installing plumber or gasfitter shall observe that a hard wired carbon monoxide detector with an alarm and battery back-up is installed on the floor level where the gas equipment is to be installed. In addition, the installing plumber or gasfitter shall observe that a battery operated or hard wired carbon monoxide detector with an alarm is installed on each additional level of the dwelling, building or structure served by the side wall horizontal vented gas fueled equipment. It shall be the responsibility of the property owner to secure the services of qualified licensed professionals for the installation of hard wired carbon monoxide detectors. a. In the event that the side wall horizontally vented gas fueled equipment is installed in a crawl space or an attic, the hard wired carbon monoxide detector with alarm and battery back-up may be installed on the next adjacent floor level.

b. In the event that the requirements of this subdivision can not be met at the time of completion of installation, the owner shall have a period of thirty (30) days to comply with the above requirements; provided, however, that during said thirty (30) day period, a battery operated carbon monoxide detector with an alarm shall be installed.

2.APPROVED CARBON MONOXIDE DETECTORS. Each carbon monoxide detector as required in accordance with the above provisions shall comply with NFPA 720 and be ANSI/UL 2034 listed and IAS certified.

3.SIGNAGE. A metal or plastic identification plate shall be permanently mounted to the exterior of the building at a minimum height of eight (8) feet above grade directly in line with the exhaust vent terminal for the horizontally vented gas fueled heating appliance or equipment. The sign shall read, in print size no less than one half (1/2) inch in size, "GAS VENT DIRECTLY BELOW. KEEP CLEAR OF ALL OBSTRUCTIONS".

4.INSPECTION. The state or local gas inspector of the side wall horizontally vented gas fueled equipment shall not approve the installation unless, upon inspection, the inspector observes carbon monoxide detectors and signage installed in accordance with the provisions of

248CMR 5.08(2)(a)1 through 4.

(b)EXEMPTIONS: The following equipment is exempt from 248 CMR 5.08(2)(a)1 through 4:

1.The equipment listed in Chapter 10 entitled "Equipment Not Required To Be Vented" in the most current edition of NFPA 54 as adopted by the Board; and

2.Product approved side wall horizontally vented gas fueled equipment installed in a room or structure separate from the dwelling, building or structure used in whole or in part for residential purposes. (c)MANUFACTURERS REQUIREMENTS - GAS EQUIPMENT VENTING SYSTEM REQUIRED. When the manufacturer of Product Approved side wall horizontally mounted gas equipment provides a venting system design or venting system components with the equipment, the instructions provided by the manufacturer for the installation of the equipment and the venting shall include:

1.Detailed instructions for the installation of the venting system or the venting system components: and

2.A complete parts list for the venting system design or venting system.

(d)MANUFACTURER REQUIREMENTS - GAS EQUIPMENT VENTING SYSTEM NOT PROVIDED. When the manufacturer of a product approved side wall horizontally vented gas fueled equipment does not provide the parts for the venting of flue gases, but identifies "special venting systems," the following requirements shall be satisfied by the manufacturer:

1.The referenced "special venting system" instructions shall be included with the appliance or equipment installation instructions; and

2.The "special venting systems" shall be product approved by the Board, and the instructions for that system shall include a parts list and detailed installation instructions.

(e) A copy of all installation instructions for all products approved side wall horizontally vented gas fueled equipment, all venting instructions, all parts lists for venting instructions, and/or all venting design instructions shall remain with the appliance or equipment at the completion of the installation.

20

6 720 607 909

Image 20
Contents Temperature Modulated with Electronic Ignition What to do if you smell gasIndex For your safetyIndex FCC Appliance details FeaturesGWH-345/450-ESR Specifications Technical data Unpacking the GWH-345/450-ESR heater Appliance details Water resistantInlet air restrictors GWH-345/450-ESR is not approved or designed forGeneral rules to follow for safe operation Dimensions and minimum installation clearances DimensionsApplications IntroductionPump Sizing Instantaneous water heater direct tank load designPressure InletWater flow rate Water qualityInstallation instructions Proper location for installing your heaterHeater placement and clearances Mounting installationCombustion air requirements Twin pipeSingle pipe Appliances located in unconfined spaces720 607 Vent lengths Vent material and specificationsVenting Vent Safety System Vent materialExhaust vent connection Installation instructions Selecting inlet air restrictor ExhaustIntake ExampleCombustion air inlet connection Mounting sequenceInstallation instructions Condensate drain requirements Room sealed installation Twin pipeVent terminations Interior masonry chimneysExterior Masonry Chimney Horizontal terminations720 607 Description Minimum distance Horizontal side wall venting installation Gas piping & connections GAS ConnectionsFor Natural GAS Measuring gas pressure Checking restrictor plate size by measuring CO2 level valueWater connections Electrical connectionsFor your safety read before operating your water heater Operating instructionsInitial filling instructions Operating instructionsPower Recirculating water temperatureTemperature and hot water flow Freeze protectionElectrical diagram Electrical schemeMaintenance and service Service modeParameter storage Maintenance and service Mode Parameter ValuesExiting service mode Fault Indication Possible Cause Check TroubleshootingTroubleshooting Check air vent GWH-345/450-ESR Functional scheme GWH-345/450-ESR Functional schemeInterior components Interior components diagram and parts listInterior components diagram and parts list Components diagram Components DiagramParts list Description ReferenceProtecting the environment Protecting the environmentPacking ComponentsTen Year Limited Warranty Bosch Thermotechnology Corporation

GWH-345/450-ESR-L, GWH-345/450-ESR-N specifications

Bosch Appliances has long been recognized for its innovative and high-quality home appliances, and the GWH-345/450-ESR-N and GWH-345/450-ESR-L water heaters are no exception. These models offer exceptional efficiency and reliability, making them ideal choices for modern households seeking dependable water heating solutions.

One of the standout features of the GWH-345/450-ESR series is their impressive energy efficiency. Engineered with cutting-edge technology, these units operate with high thermal efficiency ratings. This not only translates to reduced energy bills for consumers but also supports environmentally friendly practices by minimizing energy consumption. The tankless design eliminates the need for a storage tank, providing hot water on demand while ensuring that no energy is wasted in heating and re-heating stored water.

Both models come equipped with advanced safety features. The integrated combustion management system ensures precise control of the combustion process, which not only enhances heating efficiency but also reduces the risk of overheating. Additionally, the built-in safety mechanisms, such as flame failure protection and overheat protection, provide consumers with peace of mind knowing their home is protected.

These Bosch water heaters also feature a user-friendly digital display that allows for easy temperature adjustment and monitoring. The intuitive interface enables users to set their desired water temperature with precision, ensuring comfort and convenience. Furthermore, these models are designed for quiet operation, making them suitable for installation in various locations within the home without causing disruptive noise.

The construction of the GWH-345/450-ESR-N and GWH-345/450-ESR-L models is robust, featuring high-quality materials that ensure durability and longevity. The compact and sleek design allows for flexible installation options, even in smaller spaces. With a variety of venting options available, including direct vent and power vent configurations, these heaters can fit seamlessly into different home layouts.

In summary, Bosch Appliances GWH-345/450-ESR-N and GWH-345/450-ESR-L models represent the pinnacle of modern water heating technology. With their energy-efficient performance, advanced safety features, user-friendly controls, and durable construction, these water heaters are designed to meet the demands of today’s homes while delivering reliable hot water whenever needed. These innovative appliances reinforce Bosch's reputation as a leader in home heating solutions, ensuring that customers can enjoy hot water with confidence and peace of mind.