Wegener Communications DVR396, DVR395 manual Connector, Ferrite Size

Models: DVR395 DVR396

1 30
Download 30 pages 6.31 Kb
Page 12
Image 12

Page 12

installations, but especially in multi-service environments, should use high-quality shielded cables, with the shield grounded according to good engineering standards.

1.4.1.2Ferrite Installation

For this installation, there are three ferrites that are larger than the others. These should be used for the cables numbered 6, 7, and 8 in the list below. These are the relay cables, the video cable, and the S-Video cable. The other five cables will normally have a smaller total diameter, and should fit into the smaller ferrites.

These ferrites must be installed on cables attached to the following connectors:

 

Connector

Ferrite Size

1.

Audio 1 Left

Small

2.

Audio 1

Right

Small

3.

Audio 2

Left

Small

4.

Audio 2

Right

Small

5.

Serial Port

Small

6.

Alarm and Closure Relays.

Large

 

One ferrite for all wires to relays.

 

7.

Video

 

Large

8.

S-Video

Large

The cables must pass through the ferrite and then loop around and pass through again. See Figure 1 (Page 11). For proper results, the core should be positioned on the cable as close to the chassis connector as possible. With minimal slack in the loop, the wiring alone should properly support the core. No additional support should be necessary.

DVR395/DVR396-002

Page 12 of 30

Page 12
Image 12
Wegener Communications DVR396, DVR395 manual Connector, Ferrite Size