Page 23

SECTION 3

SETUP

3.1GENERAL

This section provides procedures for initial setup of the unit.

3.2ON SCREEN DISPLAY (OSD)

The OSD information is contained in the video output from the receiver. It is turned on by pressing either the <SELECT> or <ENTER> push-button on the front panel. The display is removed by selecting Exit from the Main Menu. When a menu is first shown, the cursor is always placed on its first action field (or action with edit field, which ever is first).

The OSD provides the following information and actions:

1.Carrier Status.

2.Signal Strength Monitoring.

3.Selecting the Perm Settings

4.Selecting the Serial Port device.

5.Software Version.

All menus are white text with a solid blue background with highlight as blue text on white background. There are four field types: Action, Action w/ Edit, Edit, Edit w/ Choices. The cursor can be moved only to these fields. The function of the <SELECT> and <ENTER> push- button for each field type is described below.

Table 7. SELECT And ENTER Key Functions

FIELD

SELECT

ENTER

 

 

 

Action Field

Moves cursor to next action field

Takes action on the current field.

 

(or action w/ edit field, which

 

 

ever is next). Wraps at end.

 

Action w/ Edit Field

Same as for action field.

Moves cursor to corresponding

 

 

edit field.

Edit Field

If cursor is not on last digit within

Increments current digit within

 

edit field, moves cursor to next

edit field. Wraps back to

 

digit. Else, moves to next action

beginning at 9.

 

field (or action w/ edit field,

 

 

which ever is next)

 

Edit Field w/ Choices

Moves cursor to next action field

Scrolls through list of choices.

 

(or action w/ edit field, which

Wraps back to beginning on last.

 

ever is next).

 

Page 23 of 30

DVR395/DVR396-002

Page 23
Image 23
Wegener Communications DVR395, DVR396 manual Section Setup, On Screen Display OSD, Select And Enter Key Functions