Wegener Communications DVR395 Video Connections, Audio Connections, Serial Port, Computer, RJ-12

Models: DVR395 DVR396

1 30
Download 30 pages 6.31 Kb
Page 15
Image 15
VIDEO CONNECTIONS

Page 15

VIDEO CONNECTIONS

Composite: connect the composite video output to the desired unit using a standard phono plug cable. The equipment it is connected to MUST have a 75-ohm termination.

S-video:connect the S-video output to the desired unit using a standard S-video mini- DIN connector.

AUDIO CONNECTIONS

Using standard shielded audio cable with phono plugs, connect the stereo audio output to the desired unit or equipment.

Serial Port

Using a cable terminated in an RJ-12 connector at one end and a DB9/DB25 at the other, connect the serial port to a terminal, printer, modem, or COMPEL control system.

A Null modem cable or adapter is required for use with a modem. Defaults are 19.2KBps, N, 8, in terminal mode.

Table 3. DVR395 Serial Cables To Terminal or Printer

 

DVR395

COMPUTER

ASCII TERMINAL OR

 

SERIAL PRINTER

 

RJ-12

DB-9

(Female)

DB-25

(Male)

 

 

 

 

 

 

 

 

PIN

 

SIGNAL

PIN

 

SIGNAL

PIN

SIGNAL

 

 

 

 

 

 

 

 

2

 

TX DATA

2

 

RX DATA

3

RX DATA

3

 

RX DATA

3

 

TX DATA

2

TX DATA

5

 

GROUND

5

 

GROUND

7

GROUND

 

 

 

 

 

 

 

 

6

 

RI

9

 

RI

22

RI

MODE SWITCH

Set the control DIP switches for NTSC/PAL, Modulator channel 2/3, Normal Video, Color Bars, and LNB ON/OFF as required for your system. See Section 2.2 (Page 17) for DIP switch information. FUNCTIONS ARE MODEL SPECIFIC.

* * * CAUTION * * *

DO NOT CONNECT RJ-12 DIRECTLY TO PHONE LINE.

Page 15 of 30

DVR395/DVR396-002

Page 15
Image 15