PREVENTIVE MAINTENANCE

PILOT AND MAIN BURNER

Check pilot and main burners at least every 12 months for the proper flame characteristics.

The pilot flame should envelop approximately 10 mm (3/8 inch) of tip of thermocouple.

10 mm

3mm

Figure 6

If the pilot flame is too small, then the pilot burner must be cleaned. The position of the igniter electrode should also be checked to assure that electrode is approximately 3 mm (1/8’’) from pilot, see figure 6.

The main burner should exhibit the following characteristics:

·Provide complete combustion of gas.

·Cause rapid ignition and carryover of flame across burners.

·Operate quickly during ignition, burning and extinction.

·Burner flames should be blue and there should be no lifting of flames from burner ports, figure 7.

If the main burners fail to exhibit above characteristics they must be cleaned, either by blowing them off with compressed air or by washing them in soap and water and rinsing.

If it proves necessary to wash the main burner assembly the following procedure should be used:

1.Turn off the gas supply to the water heater.

2.Disconnect pilot gas tube at the gas valve and unscrew the gas manifold assembly union nut, where the gas manifold inlet pipe connects to the gas valve and remove the gas burner assembly.

3.Wash in soap and water and then rinse.

4.Reassemble - Check for gas leaks after reassembly and correct as required.

5.Refer to Lighting Procedure to relight the heater.

VENTING

The vent piping and finned heat exchanger should be checked at least once a year for dust and carbon deposits and cleaned as necessary.

PRESSURE RELIEF VALVE

At least once a year the pressure relief valve should be checked to insure that if it is in operating condition. Before testing the relief valve take necessary precautions to prevent water damage. Lift the lever on the valve several times until the valve seats properly and operates freely. Do not check the relief valve when hot water is being draw and the main burner is on. Water exiting the valve under these conditions would be hot.

If the pressure relief valve on the appliance discharges this is an indication of water pressure above the pressure rating of the relief valve. If the pressure relief valve continually discharges on a periodic basis contact the water supplier or local plumbing inspector on how to correct the situation. Do not plug the pressure relief valve.

PERIODIC REMOVAL OF LIME DEPOSITS

In hard water areas, depending on frequency of use, the heater should be checked for accumulation of calcium carbonate (lime) and delimed, if necessary. Thereafter a regular schedule, based on initial inspection findings, should be set up to delime the heater. Delivering instructions are available from your Bosch dealer.

Figure 7

8

Image 8
Contents Instantaneous gas water heater What to do if YOU Smell GASDimensions LPGInstallation Instructions ForwardLocation AIR RequirementsClearances MountingVenting Water ConnectionsPropane Supply Service Hint Operating InstructionsFilling LightingPeephole High Temperature Limit SwitchTo Turn OFF GAS to Appliance Preventive Maintenance Pilot and Main BurnerVenting Pressure Relief Valve700 703 700 203 703 305 Page Interior Components Diagram Parts List Description

W 125...T1, W125K specifications

Bosch Appliances has long been synonymous with innovation, quality, and reliability, and the Bosch W125K/W125...T1 models are no exception. These appliances are thoughtfully designed to enhance user experience while providing advanced functionalities that cater to modern household needs.

One of the standout features of the Bosch W125K/W125...T1 is its energy efficiency. These models boast impressive energy ratings that help reduce electricity consumption, making them an eco-friendly choice for environmentally conscious consumers. With advanced inverter technology, the appliances ensure optimal energy use without compromising performance, which not only benefits the environment but also lowers utility bills.

The W125K/W125...T1 series incorporates innovative cleaning technologies, including intelligent sensors that detect load size and soil level. This ensures that each cycle is perfectly adjusted for maximum cleaning power while minimizing resource usage. The auto-dosing feature is another highlight, allowing users to fill detergent and fabric softener in one go, ensuring the right amount is used every time.

The user interface has been designed with simplicity in mind. A sleek, intuitive control panel with clear displays makes it easy for users to select from a variety of wash programs, temperature settings, and drying options. The addition of a smartphone app allows users to control and monitor their appliances remotely, which adds a new level of convenience for busy households.

Noise reduction is another priority in the design of the Bosch W125K/W125...T1. These appliances are engineered with special sound insulation materials and advanced motor technologies that significantly reduce operating noise, making them an ideal choice for open-plan living spaces or homes where quiet is essential.

Finally, Bosch includes robust safety features, such as child locks and overflow protection, to ensure peace of mind during operation. The stainless-steel finish not only contributes to the appliance's modern aesthetic but also enhances durability, promising years of reliable service.

In summary, the Bosch W125K/W125...T1 series combines energy efficiency, intelligent cleaning technologies, user-friendly interfaces, quiet operation, and robust safety features. These appliances exemplify Bosch's commitment to providing high-quality, innovative solutions for contemporary living, making them an excellent addition to any modern home.