Bradford-White Corp EF60T150(E)*(N, X)(A)(2), EFR160T120*(EN, EF100T250(E)*(N, EF100T150(E)*(N

Page 7

Power supply

Dedicated 120 VAC, 60 Hz, 15A, GFI

 

 

Gas Supply

Minimum 1" NPT for EF100T399, all others ¾" NPT

(schedule 40 black iron pipe recommended)

 

Approved Gas Type

Natural or Propane. Unit must match gas type supplied.

 

 

Gas Pressure (Nat & L.P.)

14.0" W.C. maximum static, 4.5" W.C. minimum running (recommend 7.0" W.C. min running)

 

 

Venting System

Power vent, balanced direct vent or unbalanced direct vent. See vent tables on page 7

 

 

 

Approved Vent Materials

PVC or CPVC

 

 

 

 

Minimum Clearance

18" from top, 24" from front, 4" sides and rear.

for Servicing

 

 

 

 

 

Maximum Water Supply

150 PSI

 

Pressure

 

 

 

 

 

Thermostat Sensor

11,900 Ohms @ 70°F, ECO opens @ 201°F Max., ECO close @ 100°F Min.

 

 

Temperature Dial

Min. set point 5400-6600 ohms, Max set point 0-50 ohms.

 

 

Thermostat Board

Max temp 180°F, Min temp 91°F, 24VAC, 60Hz max.

 

 

Ignition Module

See “Sequence of Operation, for models starting with CF serial and later”

 

 

Transformer

120VAC primary, 24VAC secondary, 40VA.

 

 

Hot Surface Igniter

120VAC, 30-120 ohms @ room temperature.

 

 

Flame Sensor Output

Minimum 1 micro amp, Typical range 4 to 7 micro amps.

 

 

Gas Valve

Negative regulation, 24 VAC, ½" PSI max., 4.5" W.C. Minimum running inlet.

 

 

Vent Safety Switch

Normally closed, opens @ 350°F, manual reset.

 

 

 

Intake Pressure Switch

 

 

“CF” serial number or

Not required.

 

later

 

 

Intake Pressure Switch

 

 

serial numbers prior to

24VAC, normally closed, opens on vacuum increase @ -1.20 W.C.

“CF”

 

 

Blocked Vent Pressure

 

 

Switch “CF” serial

24VAC, normally closed, opens when pressure increases to +2.70 W.C.

number or later

 

 

 

24VAC, normally open, closes on pressure increase as follows

 

Note 1:

 

 

+2.58" W.C.

EF(60,100)T199

Exhaust pressure switch

+1.50" W.C.

EF100T150 (see note 2)

serial numbers prior to

+1.22" W.C.

EF60T150, EF100T250

“CF”

+2.08" W.C.

EF60T125

 

+0.55" W.C.

EF100T300 (see note 3)

 

Note 2: +5.6" W.C. on serials prior to AH5039107

 

Note 3: +0.8" W.C. on serials prior to AK5288269

 

 

Blower

120VAC, 60Hz, .6-1 amps, 6400 RPM.

 

 

Combustion Levels

CO2: 10-11%, CO: less then 0.04 percent (400 PPM) air free

 

 

 

 

 

7

7

Image 7
Contents Service Manual Bradford White Page Page Page Dimensions Inches Page Page PVC, Cpvc For models prior to CF serial numbers Wiring Diagram Ignition Module For models starting with CF serial numbers and later Wiring Diagram Ignition Module Page CONNECTION/WIRING Diagram Light burned out Replace switchRepair/replace wire Harness to switchPressure Switch See Blower Testing Only power light Is on and water heater Will not functionSwitch. see Exhaust Pressure Switch See Thermostat CircuitDisplay System Observation For models with Direct Spark IgnitionSection Combustion System From previousReplace blower Blower. Is 110-120 VAC present?Pressing Select button will change display to next mode Max Setpoint value Water Heater Display Setpoint Display/Change Software Version Display only Max Setpoint continues to flash while making adjustments ExitingSELECTServiceSETMode To Display Flame Sense Current of the Pilot Flame Sensor Select SET Setpoint Idle Status Operational Idle Status Operational Error Codes and Error History Display To view previous error codes ExitingSELECTServiceSETMode Honeywell Integrated Control Error Code Resetting Error Codes in Hard Lockout Condition Next Unplug or disconnect electrical power to the water heaterDo not operate water heater without See Thermostat Potentiometer OK, thermostat is Calling for heatSee Thermostat Sensor Replace harnessAppendix a Refer to ignition module Red Wires Temperature SensorWiring Diagram Thermostat Board Replacement Procedure Hot Surface IgnitionDisconnected using a multi-meter Thermostat Potentiometer Replacement ProcedureVolt potential exposure. Isolate Thermostat Sensor Thermister Replacement ProcedureHeater not running See illustrations at right Venturi Adjustment Inlet gas Pressure tapSupply piping Gas pressure. Is it stableClear obstruction See Ignition ModuleRecommended Minimum ¾ NPT. Schedule 40 black Iron PipeLight? Control Board Refer to control board illustrationGas Connection PVC vent connection Combustion System Removal ProcedureGas valve Wire harness Burner mounting Screw TotalGas Combustion System Replacement ProcedureBurner Tube Removal Procedure Burner Tube Inspection Burner Tube Replacement ProcedureGas Valve Replacement Procedure Black & White Wires For Direct Spark Black wires atBlack wire leading to Is collector high limit switch Control boardBlower Replacement Procedure See photo below Check Purge LED status On ignition module Only power LED is on, or Purge LED flashingReset button Refer to Check Collector Pressure See next Is there continuity Through REDEF60T150,EF100T250 +1.22 EF60T125 +2.08 EF100T300 +0.55 Check Collector PressureCheck exhaust collector pressure at the exhaust EF60,100T199 +2.58 EF100T150 +1.50Exhaust collector Exhaust Pressure Switch Replacement ProcedureExhaust pipe Pressure tap location Energize? Switch operationError code 29 again? Support Reset buttonPressure tap location Exhaust tube At bottom of heater Check Exhaust Tube PressureIs value negative or Vent tablesExhaust Tube Pressure tap location Check during igniter warm up period Hot surface Igniter Testing ProcedureCheck harness Connection from igniter To ignition module Screws Hot surface Igniter Replacement ProcedureSensor Flame Sensor Testing ProcedureGasket Check continuity from tip of flame sensor NFlame Sensor Replacement Procedure Spark Rod Gap Inspection and Adjustment Spark Rod Replacement Procedure Ignition Module Located on control panel Ignition Module Replacement ProcedureIdentify wires for Step Transformer Replacement ProcedureStep Disconnect harness P1 & P2 From ignition module Or more? Does Blower Energize?Pressure tap Call for technical support Step Disconnect red wires Intake Pressure Switch Replacement ProcedureStep Remove Mounting screws Button on high System OK Reset buttonVent Safety Switch Replacement Procedure Disassembly Procedure for Access to Anodes & Flue Baffles Anode inspection and replacement Flue baffle inspection and replacement Powered Anode Replacement EF100T399 models only Collector Cover Installation Procedure Vent tables Spark Gap Gas Line Gas Pressure VenturiModels prior to CF serial number Latch Assy Electronic Control Module For models with CF serial or later Combustion Surround Assy. specify Electronic Control Module For models with Direct Spark Ignition Honeywell Control Display 10C 11C 12C 13C BTU/H Page Page Parts@bradfordwhite.com Techserv@bradfordwhite.com

EFR160T120*(EN, EF100T250(E)*(N, EF100T399(E)*(N, EF100T300(E)*(N, EF60T125(E)*(N specifications

Bradford-White Corporation is a leading manufacturer of water heating solutions, known for its high-quality and durable products. Among its extensive product lineup, the EF60T150(E)*(N), EF100T150(E)*(N), EF60T199(E)*(N,X)(A)(2), and EF100T199(E)*(N) models stand out for their impressive features and technologies that cater to both residential and commercial water heating needs.

The EF60T150(E)*(N) model is designed for medium to large households, providing a reliable hot water supply. It features a 60-gallon tank with a first-hour delivery rate that ensures ample hot water, making it ideal for simultaneous usage in multiple applications. This water heater operates on natural gas, boasting high energy efficiency ratings due to its advanced burner technology. The environmentally friendly design reduces greenhouse gas emissions while delivering consistent performance.

Similarly, the EF100T150(E)*(N) model provides an even larger capacity of 100 gallons, addressing the hot water demands of larger families or commercial establishments. It employs Bradford-White's Hydrojet Total Performance System, which minimizes sediment buildup and optimizes hot water output. This model also features a patented Vitraglas lining that protects the tank from corrosion, extending its lifespan and enhancing reliability.

On the other hand, the EF60T199(E)*(N,X)(A)(2) and EF100T199(E)*(N) models offer advanced technology with their unique "N" designation, indicating that they are equipped to handle more extensive heating requirements efficiently. The EF60T199 model, with its 60-gallon capacity, and the EF100T199, with 100 gallons, incorporate enhanced insulation to reduce heat loss and improve energy efficiency. Both models are designed for easy installation and maintenance, making them user-friendly for both homeowners and technicians.

Additionally, these water heaters feature advanced electronic ignition and controls that allow for precise temperature regulation and easy monitoring. The intuitive user interface simplifies operation, while built-in safety features ensure reliable and secure hot water delivery.

Overall, Bradford-White's EF series of water heaters, including the EF60T150(E)*(N), EF100T150(E)*(N), EF60T199(E)*(N,X)(A)(2), and EF100T199(E)*(N), exemplify the company's commitment to quality and innovation. With their robust performance, energy efficiency, and advanced technologies, these models offer dependable hot water solutions tailored to meet the diverse needs of today's consumers. Whether for residential or commercial use, Bradford-White continues to set the standard for excellence in water heating technology.