Bradford-White Corp D38T155 service manual Service Procedure D24-II, Pilot Operation Testing

Page 8

SERVICE PROCEDURE D24-II

Pilot Operation Testing

DANGER

120 volt exposure. To avoid personal injury, use caution while performing this procedure.

CAUTION

Be Careful When Making Voltage

Measurements or Jumping Terminals

Not to Damage or Deform Connectors or

Connector Pins.

 

 

 

Condition:

 

 

 

 

 

 

 

11

 

Pilot will not light,

 

 

 

 

 

 

 

Ignition module LED is “ON”

 

 

 

Check across

 

 

 

 

 

 

 

 

 

 

 

 

“MV/PV” & “PV”

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

terminals

 

Reset heater by turning power

 

 

 

 

“OFF”. Wait 5 seconds and turn

 

 

 

 

 

power “ON”. When LED of

 

N

 

Replace ignition

 

ignition module turns “ON” does

 

 

module

Check across “MV/PV”

 

ignition module send “spartk”

 

 

 

& “PV” Wire leads to

signal (buzzing or clicking sound)

 

 

 

gas valve

 

 

 

 

Y

 

 

 

 

 

Check for:

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Is there spark at the

N

 

Loose or damaged ignition wire

12

 

 

 

pilot?

 

 

 

 

Grounded pilot electrode

 

 

 

 

 

Y

 

 

 

 

 

Damaged pilot.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Is there 22-27 volts AC output across

 

 

 

 

terminals “MV/PV” & “PV” of Ignition

N

 

Replace ignition

 

 

 

 

 

 

 

 

 

 

 

 

 

Module? Disconnect wires & check

 

 

 

 

module

 

 

 

 

 

 

 

 

 

 

 

 

 

 

across terminal of module.

 

 

 

 

 

 

 

(see photo 11)

Y

Is there 22-27 volts AC input

 

Loosen pilot tubing connection at

 

Check for clogged or kinked

across wire leads

 

 

Y

the gas valve and soap test.

Y

pilot tube, clogged pilot orifice.

 

 

 

 

 

 

“MV/PV” & “PV”

 

Is there pilot gas flow out of the

 

Clean or replace as needed.

at Gas Valve?

 

 

 

 

gas valve?

 

(see page 13)

 

 

 

 

 

 

 

 

 

(see photo 12)

 

 

 

 

 

 

 

 

 

 

 

 

N

 

 

 

N

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Tighten pilot tube connection at

 

 

 

 

 

 

 

 

 

the gas valve. Check incoming

 

 

 

 

 

 

 

 

 

gas pressure to water heater. if

 

 

 

 

 

 

 

 

 

okay, replace gas valve

 

 

 

 

 

 

 

 

 

 

ECO Specifications

 

 

13

Check continuity across ECO

 

 

 

 

 

 

 

(RED) leads of lower thermister N

Opens between 181°F/201°F

 

 

(see photo 13)

 

Closes between 160°F/100°F

 

 

Is continuity okay?

Y

Check wire harness for damage or loose connections. Repair or replace as needed.

Check across RED wire leads of lower thermister (ECO).

Page 8

8

Image 8
Contents Service Manual To be performed only by qualified service providersTable of Contents Tools Required for Service Sequence of Operation Lockout ConditionTroubleshooting To Avoid Personal InjuryDo not leave thermostat jumper Place for normal operation Service Procedure D24-IThermostat Circuit Testing Upper Thermister Lower ThermisterService Procedure D24-II Pilot Operation TestingIllustration ConditionService Procedure D24-III Main Burner Operation TestingProvide proper Service Procedure D24-IV Main Burner & Pilot Removal and InspectionMain Burner Removal Main Burner InspectionPilot Burner Removal Pilot Burner InspectionService Procedure D24-V Flue Baffle Removal, InspectionService Procedure D24-VI Generic Parts List 1/8 Reducer Bushing Temperature Control Knob BTU/H CO2ECO GFIParts@bradfordwhite.com Techserv@bradfordwhite.com

Commerical 24 Volt Flue Damper series Water Heater, D38T155 specifications

Bradford-White Corporation is recognized for producing high-quality water heating solutions, and one of the standout products in their lineup is the D38T155 Commercial 24 Volt Flue Damper Series Water Heater. This water heater exemplifies the company’s commitment to efficiency, reliability, and advanced technology tailored to meet the demands of commercial establishments.

The D38T155 model features a robust design, engineered to provide consistent hot water delivery for a range of commercial applications. With a 38-gallon capacity, it is ideal for small to medium-sized businesses, including restaurants, hotels, and other facilities that require dependable access to hot water.

One of the key features of the D38T155 is its 24-volt flue damper system, which enhances energy efficiency. This technology prevents heat loss by closing the damper when the water heater is not in operation. As a result, the unit minimizes energy waste, contributes to lower utility bills, and simplifies compliance with stringent energy regulations. The flue damper's precision operation ensures that only the required amount of energy is utilized, optimizing performance.

The water heater is also equipped with a direct vent design. This allows for the safe venting of combustion gases, making it suitable for indoor installations while ensuring the surrounding environment remains safe and free of harmful emissions. The advanced insulation technology utilized within the tank further preserves heat, reducing the frequency of heating cycles and extending the lifecycle of the appliance.

In terms of maintenance, the D38T155 is designed with accessibility in mind. Its components are placed for easy access, allowing maintenance personnel to perform inspections and repairs with minimal disruption. This user-friendly design ensures that downtime is kept to a minimum, effectively supporting the operational needs of commercial facilities.

The Bradford-White D38T155 also showcases durability through its high-quality materials and comprehensive manufacturing process. Built with a glass-lined tank, it provides excellent corrosion resistance, prolonging the life of the water heater.

In summary, the Bradford-White D38T155 Commercial 24 Volt Flue Damper Series Water Heater combines advanced technology, energy efficiency, and reliable performance. With its user-centric design and durable construction, it stands as an optimal solution for businesses looking to meet their hot water needs effectively and economically.