Bradford-White Corp Commerical 24 Volt Flue Damper series Water Heater, D38T155 Troubleshooting

Page 5

TROUBLESHOOTING

CAUTION

Use Caution Not to Damage Connectors when making Voltage Measurements or Jumping Terminals

Verify Primary and secondary voltage

1

DANGER

120 volt exposure. Use Caution

at the transformer

 

(see photo 1)

 

To Avoid Personal Injury.

 

 

 

 

 

 

Rear terminals

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

primary

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Ignition Module LED Status

 

 

 

 

 

 

(120 VAC)

 

 

 

 

 

 

 

 

If LED on ignition module is flashing,

 

 

 

 

 

 

 

OFF = No power to module

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ON = Module has power

reset water heater by turning “OFF”

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Flashing = Module is in lock-out

power. Wait 5 seconds and turn

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

power back “ON”

 

 

Forward terminals

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

secondary

 

 

Ignition module

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(24 VAC)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Rotate thermostat dial to the

 

 

 

 

 

See thermostat testing

 

 

 

 

 

highest setting.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(page 6).

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Remove damper from

 

 

 

 

N

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Does damper vane Move to the full

N

 

heater and

 

 

Does LED light on

Y

 

Check for debris limiting

 

Jump black & yellow wires

 

 

ignition module

 

damper rotation, if no

 

 

 

 

 

 

 

 

 

 

open position?

 

 

 

 

 

 

 

 

 

of heater harness

 

 

illuminate?

 

 

debris, replace damper

 

 

 

 

 

 

 

 

 

 

 

Y

 

 

(see photo 2)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Is there 24 VAC between

Y

 

Replace ignition module

 

1A

 

 

 

 

 

 

 

 

Does LED light on ignition module

N

 

terminals “TR” & “TH” of the

 

 

 

 

 

 

 

illuminate?

 

 

ignition module?

 

 

Check damper harness

 

 

 

 

 

 

 

 

 

 

 

(see photo 1A)

 

 

connection.

 

 

 

 

 

 

Y

 

 

N

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

N

 

See pilot will not light

 

 

 

 

 

 

 

 

 

 

Is there pilot flame?

 

 

 

 

 

 

 

 

 

 

 

 

 

(page 8)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Y

 

 

 

 

 

 

 

Check for 24 VAC

 

 

 

 

 

 

 

 

across terminals

 

 

 

 

 

 

 

 

 

 

 

“TR” & “TH”

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Does Main burner operate?

N

See pilot lights, no flame

signal.

 

 

 

 

(page 9)

 

Y

 

 

 

 

 

 

 

 

See main burner

Does burner continue until thermostat

N

short cycle

set point is reached?

 

 

(page 11).

 

 

 

 

Y

 

 

 

 

 

 

 

 

Check for debris limiting

Does flue damper rotate to the closed

N

damper rotation, if no

position?

 

 

debris, replace damper

 

 

 

 

Y

 

 

 

 

 

 

 

 

 

System okay.

Page 5

Damper vane show in open position. If damper

is closed, disconnect from harness and REMOVE damper from water heater.

2

Harness shown disconnected from damper with BLACK and YELLOW wires jumped.

5

Image 5
Contents To be performed only by qualified service providers Service ManualTable of Contents Tools Required for Service Lockout Condition Sequence of OperationTo Avoid Personal Injury TroubleshootingDo not leave thermostat jumper Place for normal operation Service Procedure D24-IThermostat Circuit Testing Lower Thermister Upper ThermisterPilot Operation Testing Service Procedure D24-IICondition IllustrationMain Burner Operation Testing Service Procedure D24-IIIProvide proper Main Burner & Pilot Removal and Inspection Service Procedure D24-IVMain Burner Removal Main Burner InspectionPilot Burner Inspection Pilot Burner RemovalFlue Baffle Removal, Inspection Service Procedure D24-VService Procedure D24-VI Generic Parts List 1/8 Reducer Bushing Temperature Control Knob CO2 BTU/HECO GFIParts@bradfordwhite.com Techserv@bradfordwhite.com

Commerical 24 Volt Flue Damper series Water Heater, D38T155 specifications

Bradford-White Corporation is recognized for producing high-quality water heating solutions, and one of the standout products in their lineup is the D38T155 Commercial 24 Volt Flue Damper Series Water Heater. This water heater exemplifies the company’s commitment to efficiency, reliability, and advanced technology tailored to meet the demands of commercial establishments.

The D38T155 model features a robust design, engineered to provide consistent hot water delivery for a range of commercial applications. With a 38-gallon capacity, it is ideal for small to medium-sized businesses, including restaurants, hotels, and other facilities that require dependable access to hot water.

One of the key features of the D38T155 is its 24-volt flue damper system, which enhances energy efficiency. This technology prevents heat loss by closing the damper when the water heater is not in operation. As a result, the unit minimizes energy waste, contributes to lower utility bills, and simplifies compliance with stringent energy regulations. The flue damper's precision operation ensures that only the required amount of energy is utilized, optimizing performance.

The water heater is also equipped with a direct vent design. This allows for the safe venting of combustion gases, making it suitable for indoor installations while ensuring the surrounding environment remains safe and free of harmful emissions. The advanced insulation technology utilized within the tank further preserves heat, reducing the frequency of heating cycles and extending the lifecycle of the appliance.

In terms of maintenance, the D38T155 is designed with accessibility in mind. Its components are placed for easy access, allowing maintenance personnel to perform inspections and repairs with minimal disruption. This user-friendly design ensures that downtime is kept to a minimum, effectively supporting the operational needs of commercial facilities.

The Bradford-White D38T155 also showcases durability through its high-quality materials and comprehensive manufacturing process. Built with a glass-lined tank, it provides excellent corrosion resistance, prolonging the life of the water heater.

In summary, the Bradford-White D38T155 Commercial 24 Volt Flue Damper Series Water Heater combines advanced technology, energy efficiency, and reliable performance. With its user-centric design and durable construction, it stands as an optimal solution for businesses looking to meet their hot water needs effectively and economically.