SERVICE PROCEDURE D24-VI

Anode Removal and Inspection

WARNING

Heater components may be HOT when performing the following steps in this procedure.

Take necessary precaution to prevent personal injury.

Step 1. Disconnect (unplug) water heater from electrical supply.

Step 2. Turn “OFF” water supply to water heater.

Step 3. Open a near by hot water faucet to relieve tank pressure.

Step 4. Connect hose to drain valve of water heater and route to an open drain. Open

drain valve and drain approximately 1 gallon of water from the water heater. Close drain valve and disconnect drain hose from water heater.

Step 5. Disconnect venting from draft diverter and remove draft diverter from top of water heater.

Step 6. Disconnect flue damper from wire harness and remove flue damper from top of water heater.

Step 7. If required disconnect top plumbing connection from top of water heater.

Step 8. Remove screws holding jacket head to top of water heater and remove jacket head from top of water heater.

Step 9. Remove insulation from top of water heater to expose collector cover.

Step 10. Remove screw from side (or top) of collector cover and remove collector cover from water heater.

Step 11. Locate and remove anode rods from top of water heater (1-1/16 hex socket).

Step 12. Visually inspect anode rod. Anode rod should show signs of depletion, this is normal. If the depletion is half the original diameter (approximately ¾"), replacement is recommended. If any of the steel core of the anode is exposed, replacement is recommended.

Step 13. Upon completion of inspection or subsequent replacement, reinstall anode rods into heater.

Step 14. Reinstall collector cover and insulation over collector cover.

Step 15. Reinstall jacket head, flue damper and draft diverter. Reconnect venting.

Step 16. Reconnect plumbing connection to top of water heater if required.

Step 17. Restore water supply and power to water heater.

Page 15

15

Image 15
Contents To be performed only by qualified service providers Service ManualTable of Contents Tools Required for Service Lockout Condition Sequence of OperationTo Avoid Personal Injury TroubleshootingService Procedure D24-I Thermostat Circuit TestingDo not leave thermostat jumper Place for normal operation Lower Thermister Upper ThermisterPilot Operation Testing Service Procedure D24-IICondition IllustrationMain Burner Operation Testing Service Procedure D24-IIIProvide proper Main Burner Inspection Service Procedure D24-IVMain Burner & Pilot Removal and Inspection Main Burner RemovalPilot Burner Inspection Pilot Burner RemovalFlue Baffle Removal, Inspection Service Procedure D24-VService Procedure D24-VI Generic Parts List 1/8 Reducer Bushing Temperature Control Knob GFI BTU/HCO2 ECOParts@bradfordwhite.com Techserv@bradfordwhite.com

Commerical 24 Volt Flue Damper series Water Heater, D38T155 specifications

Bradford-White Corporation is recognized for producing high-quality water heating solutions, and one of the standout products in their lineup is the D38T155 Commercial 24 Volt Flue Damper Series Water Heater. This water heater exemplifies the company’s commitment to efficiency, reliability, and advanced technology tailored to meet the demands of commercial establishments.

The D38T155 model features a robust design, engineered to provide consistent hot water delivery for a range of commercial applications. With a 38-gallon capacity, it is ideal for small to medium-sized businesses, including restaurants, hotels, and other facilities that require dependable access to hot water.

One of the key features of the D38T155 is its 24-volt flue damper system, which enhances energy efficiency. This technology prevents heat loss by closing the damper when the water heater is not in operation. As a result, the unit minimizes energy waste, contributes to lower utility bills, and simplifies compliance with stringent energy regulations. The flue damper's precision operation ensures that only the required amount of energy is utilized, optimizing performance.

The water heater is also equipped with a direct vent design. This allows for the safe venting of combustion gases, making it suitable for indoor installations while ensuring the surrounding environment remains safe and free of harmful emissions. The advanced insulation technology utilized within the tank further preserves heat, reducing the frequency of heating cycles and extending the lifecycle of the appliance.

In terms of maintenance, the D38T155 is designed with accessibility in mind. Its components are placed for easy access, allowing maintenance personnel to perform inspections and repairs with minimal disruption. This user-friendly design ensures that downtime is kept to a minimum, effectively supporting the operational needs of commercial facilities.

The Bradford-White D38T155 also showcases durability through its high-quality materials and comprehensive manufacturing process. Built with a glass-lined tank, it provides excellent corrosion resistance, prolonging the life of the water heater.

In summary, the Bradford-White D38T155 Commercial 24 Volt Flue Damper Series Water Heater combines advanced technology, energy efficiency, and reliable performance. With its user-centric design and durable construction, it stands as an optimal solution for businesses looking to meet their hot water needs effectively and economically.