Residential Atmospheric Vent Gas Water Heater System

Combi2Energy Saver Models

 

 

 

 

 

Meet or exceed ASHRAE 90.1b (current standard) C.E.C. Listed

NATURAL GAS AND LIQUID PROPANE GAS

 

 

 

 

 

 

 

80% Recovery Efficiency

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Model

Capacity

 

 

 

Recovery

 

A

B

C

D

E

F

G

H

J

K

Approx.

 

 

 

90°F Rise*

 

Floor to

Jacket

Vent

Floor to

Floor

Floor

Floor

Floor

Floor

Depth

Shipping

Number

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Flue

Dia.

Size

T&P

to

to

to

to

to

 

Weight

 

 

 

 

LP

Nat.

Nat.

LP

LP

 

 

 

 

Nat.

Conn.

 

 

Conn.

Gas

Exchanger

Exchanger

Top of

Water

 

 

 

U.S. Imp.

BTU/Hr.

BTU/Hr.

U.S.

Imp.

U.S.

Imp.

in.

in.

in.

in.

Conn.

Inlet

Outlet

Heater

Conn.

in.

lbs.

 

Gal.

Gal.

Input

Input

GPH

GPH

GPH

GPH

in.

in.

in.

in.

in.

C-DW2-504T10FBN

45

38

65,000

61,000

70

59

66

55

5914

22

4

50

13

2778

50

5638

57

2412

238

C-DW2-75T10BN

72

61

76,000

76,000

81

70

81

70

6334

26

4

53

16

3078

53

6014

6114

2812

328

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Model

Capacity

 

 

 

Recovery

 

A

B

C

D

E

F

G

H

J

K

Approx.

 

 

 

50°C Rise*

 

Floor to

Jacket

Vent

Floor to

Floor

Floor

Floor

Floor

Floor

Depth

Shipping

Number

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Flue

Dia.

Size

T&P

to

to

to

to

to

 

Weight

 

 

 

 

LP

Nat.

LP

 

 

 

 

Nat.

Conn.

 

 

Conn.

Gas

Exchanger

Exchanger

Top of

Water

 

 

 

Liters

kW

kW

Liters/

Liters/

mm.

mm.

mm.

mm.

Conn.

Inlet

Outlet

Heater

Conn.

mm.

kg.

 

Input

Input

Hour

Hour

mm.

mm.

mm.

mm.

mm.

C-DW2-504T10FBN

170

19.1

17.9

265

250

1403

559

102

1270

330

1505

1505

1432

1447

622

108

C-DW2-75T10BN

272

22.3

22.3

317

317

1530

660

102

1346

406

1619

1619

1619

1556

724

149

All Propane heaters are equipped with a cast iron burner. To order a Propane heater change suffix “BN” to “CX”. *Based on manufacturers rated recovery efficiency.

 

C

 

K

A

D & G

 

J

 

H

 

F

 

E

Note: (C-DW2-75T will not have a pedestal base)

Meets NAECA Requirements

Heat Exchanger

Head Loss

 

 

 

GPM

Ft. of

 

 

 

 

Hd. Loss

 

 

 

2

trace

 

 

 

5

0.4

 

 

 

8

2.3

B

 

 

10

4.6

 

 

 

12

6.9

 

C-DW2-504T10

C-DW2-75T10

Model Number

FBN

FCX

BN

CX

Water Heating

 

 

 

 

FHD

105

100

135

135

U.S. Gal.

U.S. Gal.

U.S. Gal.

U.S. Gal.

 

CAEF

.55

.55

.52

.52

Space Heating

 

 

 

 

CAAFUE%

80.0

80.0

82.0

82.0

Max. Heating

 

55,000

55,000

 

Capacity

 

BTU/Hr.

BTU/Hr.

 

 

(16.1 kW)

(16.1 kW)

Based on ANSI Z-21.10.1 and 10.3 and DOE Test Methods. Based on ANSI/ASHRAE 124 Standard.

Actual values may vary based on circulator flow rate, number of zones, water and space heating demands. Numbers subject to change.

General

All gas water heaters are certified at 300 PSI test pressure (2068 kPa) and 150 PSI working pressure (1034 kPa). All potable water and heat exchanger connections are 3⁄4" NPT (19mm) on 11" (203mm) centers. All gas connections 1⁄2" (13mm).

All models design certified by CSA International (formerly AGA/CGA), ANSI Z-21.10.1 and/or 10.3 and peak performance rated.

Dimensions and specifications subject to change without notice in accordance with our policy of continuous product improvement.

Suitable for Water (Potable) Heating and Space Heating.

Toxic chemicals, such as those used for boiler treatment, shall NEVER be introduced into the potable water side. The potable side of this unit may NEVER be connected to any existing heating system or component(s) previously used with a non-potable water heating appliance. The heat exchanger side of the unit may be used in space heating applications.

Ambler, PA

For U.S. and Canada field service, contact your professional installer or local Bradford White sales representative.

Sales 800-523-2931 Fax 215-641-1670 / Technical Support 800-334-3393 Fax 269-795-1089 Warranty 800-531-2111 Fax 269-795-1089

International: Telephone 215-641-9400 Telefax 215-641-9750 / www.bradfordwhite.com

Sales / Technical Support 866-690-0961 /905-238-0100 Fax 905-238-0105 /www.bradfordwhite.com

©2007, Bradford White Corporation. All rights reserved.

546-B-0807-A

Printed in U.S.A.

Image 2
Contents All Combi2 Models Feature Photo is DW2-504T10FBNMeets Naeca Requirements Residential Atmospheric Vent Gas Water Heater SystemCombi2 Energy Saver Models General