American Water Heater Commercial Gas Water Heaters Mixing Valves, Dishwashing Machines

Page 15

MIXING VALVES

Water temperature over 125°F (52°C) can cause severe burns instantly resulting in severe injury or death.

Children, the elderly and the physically or mentally disabled are at highest risk for scald injury.

Feel water before bathing or showering.

Temperature limiting devices such as mixing valves must be installed when required by codes and to ensure safe temperatures at fixtures.

:DWHUKHDWHGWRDWHPSHUDWXUHZKLFKZLOOVDWLVI\FORWKHVZDVKLQJ GLVKZDVKLQJDQGRWKHUVDQLWL]LQJQHHGVFDQVFDOGDQGFDXVH SHUPDQHQW LQMXU\ XSRQ FRQWDFW 6KRUW UHSHDWHG KHDWLQJ F\FOHV FDXVHGE\VPDOOKRWZDWHUXVHVFDQFDXVHWHPSHUDWXUHVDWWKH SRLQWRIXVHWRH[FHHGWKHZDWHUKHDWHU¶VWHPSHUDWXUHVHWWLQJE\ XSWRƒ) ƒ& 

6RPH SHRSOH DUH PRUH OLNHO\ WR EH SHUPDQHQWO\ LQMXUHG E\ KRW ZDWHU WKDQ RWKHUV 7KHVH LQFOXGH WKH HOGHUO\ FKLOGUHQ WKH LQ¿UP DQG WKH SK\VLFDOO\PHQWDOO\ GLVDEOHG 7DEOH  VKRZV WKH

DSSUR[LPDWH WLPHWREXUQ UHODWLRQVKLS IRU QRUPDO DGXOW VNLQ ,I DQ\RQH XVLQJ KRW ZDWHU SURYLGHG E\ WKH ZDWHU KHDWHU EHLQJ LQVWDOOHG¿WVLQWRRQHRIWKHVHJURXSVRULIWKHUHLVDORFDOFRGH

RUVWDWHODZUHTXLULQJDFHUWDLQZDWHUWHPSHUDWXUHDWWKHSRLQWRI

XVHWKHQVSHFLDOSUHFDXWLRQVPXVWEHWDNHQ

,QDGGLWLRQWRXVLQJWKHORZHVWSRVVLEOHWHPSHUDWXUHVHWWLQJWKDW

VDWLV¿HVWKHGHPDQGRIWKHDSSOLFDWLRQD0L[LQJ9DOYHVKRXOGEH LQVWDOOHGDWWKHZDWHUKHDWHU VHH)LJXUH RUDWWKHKRWZDWHU WDSVWRIXUWKHUUHGXFHV\VWHPZDWHUWHPSHUDWXUH

0L[LQJYDOYHVDUHDYDLODEOHDWSOXPELQJVXSSO\VWRUHV&RQVXOW D 4XDOL¿HG ,QVWDOOHU RU 6HUYLFH $JHQF\ )ROORZ PL[LQJ YDOYH PDQXIDFWXUHU¶VLQVWUXFWLRQVIRULQVWDOODWLRQRIWKHYDOYHV

TABLE 6

 

Water Temperature

 

Time for 1st Degree Burn

Time for Permanent Burns

 

 

QG UG'HJUHH

ƒ) ƒ&

 

/HVV6HYHUH%XUQV

 

0RVW6HYHUH%XUQV

 

 

 

QRUPDOVKRZHUWHPS

 

 

 

 

 

 

SDLQWKUHVKROG

 

 

 

 

35 minutes

45 minutes

 

 

 

1 minute

5 minutes

 

 

 

VHFRQGV

VHFRQGV

 

 

 

VHFRQGV

VHFRQGV

 

 

 

VHFRQG

VHFRQGV

 

 

 

instantaneous

VHFRQG

 

86*RYHUQPHQW0HPRUDQGXP&36&3HWHU/$UPVWURQJ6HSW

DISHWASHING MACHINES

 

$OO GLVKZDVKLQJ PDFKLQHV PHHWLQJ WKH 1DWLRQDO 6DQLWDWLRQ )RXQGDWLRQ UHTXLUHPHQWV DUH GHVLJQHG WR RSHUDWH ZLWK ZDWHU ÀRZSUHVVXUHVEHWZHHQDQGSRXQGVSHUVTXDUHLQFK  N3DDQGN3D )ORZSUHVVXUHVDERYHSRXQGVSHUVTXDUH LQFK N3D RUEHORZSRXQGVSHUVTXDUHLQFK N3D  ZLOOUHVXOWLQLPSURSHUO\VDQLWL]HGGLVKHV:KHUHSUHVVXUHVDUH

KLJKDZDWHUSUHVVXUHUHGXFLQJRUÀRZUHJXODWLQJFRQWUROYDOYH VKRXOG EH XVHG LQ WKH ƒ) ƒ&  OLQH WR WKH GLVKZDVKLQJ PDFKLQH DQG VKRXOG EH DGMXVWHG WR GHOLYHU ZDWHU SUHVVXUH EHWZHHQWKHVHOLPLWV

HOT WATER

OUTLET

12” TO 15” (30-38 cm)

TEMPERED WATER

OUTLET

COLD

CHECK

WATER

VALVE

INLET

 

MIXING

CHECK VALVE

VALVE

TO TANK

INLET

Figure 8

7KH1DWLRQDO6DQLWDWLRQ)RXQGDWLRQDOVRUHFRPPHQGVFLUFXODWLRQ

RIƒ) ƒ& ZDWHU:KHUHWKLVLVGRQHWKHFLUFXODWLRQVKRXOG EH YHU\ JHQWOH VR WKDW LW GRHV QRW FDXVH DQ\ XQQHFHVVDU\ WXUEXOHQFHLQVLGHWKHZDWHUKHDWHU7KHFLUFXODWLRQVKRXOGEHMXVW HQRXJKWRSURYLGHƒ) ƒ& ZDWHUDWWKHSRLQWRIWDNHRIIWR

WKHGLVKZDVKLQJPDFKLQH

$GMXVW ÀRZ E\ WKURWWOLQJ D IXOO SRUW EDOO YDOYH LQVWDOOHG LQ WKH FLUFXODWLQJOLQHRQWKHRXWOHWVLGHRIWKHSXPS1HYHUWKURWWOHÀRZ RQWKHVXFWLRQVLGHRIDSXPS6HHWKH:DWHU3LSLQJ'LDJUDPV EHJLQQLQJRQSDJH

NOTE:7RFRPSO\ZLWK16)6WDQGDUGLQVWDOODWLRQUHTXLUHPHQWV WKHERWWRPRIWKHZDWHUKHDWHUPXVWEHVHDOHGWRWKHÀRRUZLWKD

VLOLFRQHEDVHGVHDODQWRUHOHYDWHGLQFKHVDERYHWKHÀRRU

CLOSED WATER SYSTEMS

:DWHU VXSSO\ V\VWHPV PD\ EHFDXVH RI FRGH UHTXLUHPHQWV RU VXFK FRQGLWLRQV DV KLJK OLQH SUHVVXUH DPRQJ RWKHUV KDYH

LQVWDOOHG GHYLFHV VXFK DV SUHVVXUH UHGXFLQJ YDOYHV FKHFN YDOYHVDQGEDFNÀRZSUHYHQWHUV'HYLFHVVXFKDVWKHVHFDXVH WKHZDWHUV\VWHPWREHDFORVHGV\VWHP

THERMAL EXPANSION

$V ZDWHU LV KHDWHG LW H[SDQGV WKHUPDO H[SDQVLRQ  ,Q D FORVHGV\VWHPWKHYROXPHRIZDWHUZLOOJURZZKHQLWLVKHDWHG $VWKHYROXPHRIZDWHUJURZVWKHUHZLOOEHDFRUUHVSRQGLQJ LQFUHDVHLQZDWHUSUHVVXUHGXHWRWKHUPDOH[SDQVLRQ7KHUPDO H[SDQVLRQFDQFDXVHSUHPDWXUHWDQNIDLOXUH OHDNDJH 7KLV W\SH RI IDLOXUH LV QRW FRYHUHG XQGHU WKH OLPLWHG ZDUUDQW\

7KHUPDOH[SDQVLRQFDQDOVRFDXVHLQWHUPLWWHQW7HPSHUDWXUH 3UHVVXUH5HOLHI9DOYHRSHUDWLRQZDWHUGLVFKDUJHGIURPWKH YDOYH GXH WR H[FHVVLYH SUHVVXUH EXLOG XS 7KLV FRQGLWLRQ LV QRW FRYHUHG XQGHU WKH OLPLWHG ZDUUDQW\ 7KH 7HPSHUDWXUH 3UHVVXUH5HOLHI9DOYHLVQRWLQWHQGHGIRUWKHFRQVWDQWUHOLHI RIWKHUPDOH[SDQVLRQ

$ SURSHUO\ VL]HG WKHUPDO H[SDQVLRQ WDQN PXVW EH LQVWDOOHG RQ

DOO FORVHG V\VWHPV WR FRQWURO WKH KDUPIXO HIIHFWV RI WKHUPDO H[SDQVLRQ&RQWDFWDORFDOSOXPELQJVHUYLFHDJHQF\WRKDYHD

WKHUPDOH[SDQVLRQWDQNLQVWDOOHG

6HH:DWHU/LQH&RQQHFWLRQVRQSDJHDQGWKH:DWHU3LSLQJ

'LDJUDPVEHJLQQLQJRQSDJH

15

Image 15
Contents 7KDQN\RXIRUEX\LQJWKLVHQHUJ\HI¿FLHQWZDWHUKHDWHU Installation Operation Service Maintenance Limited WarrantyDSSUHFLDWH\RXUFRQ¿GHQFHLQRXUSURGXFWV American Water HeaterTable of Contents KHDWHUVFRYHUHGLQWKLVPDQXDO Safe INSTALLATION, USE and ServiceApprovals SRWHQWLDOHSRVXUHWRVXFKVXEVWDQFHVHydrogen GAS Flammable General Safety InformationPrecautions Grounding InstructionsFire or Explosion Hazard Installing, using or servicing Water heaterAbbreviations Used Preparing for the InstallationQualified Installer or Service Agency IntroductionBasic Operation Features and ComponentsHCG3 120 & 150 Components TOP ViewsHCG3 199 & 250 Components ,QWDNHDLUFRQQHFWLRQLQFK39& 3RZHUHGDQRGHURGV7KHZDWHUKHDWHU¶VFRYHUHGLQWKLV RQSDJHDQG&RQGHQVDWHUDLQ,QVWDOODWLRQRQSDJH Side Views DWHURXWOHWSLSH´137FRQQHFWLRQ 9HQWFRQQHFWLRQ HKDXVWHOERZ LQFK39&Front Installation ConsiderationsRough in Dimensions TOP ViewsGAS Line Connection Size Recovery CapacitiesGAS Pressure Requirements Locating the Water HeaterCirculation Pumps Extended Vent TerminationsOptional Concentric Terminations Hard WaterSupply GAS Regulator Installation RequirementsPower Supply GAS Supply SystemsThermal Expansion Mixing ValvesDishwashing Machines Closed Water SystemsValve Discharge Pipe Requirements TEMPERATURE-PRESSURE Relief ValveCondensate Drain Water Trap Condensate DrainCombustible Material Storage Contaminated AIRUnusually Tight Construction AIR RequirementsUnconfined Space Confined SpaceOutdoor AIR Through TWO Horizontal Ducts Fresh AIR Openings for Confined SpacesOutdoor AIR Through TWO Openings Outdoor AIR Through ONE OpeningWKDQLQFKHV FP  Outdoor AIR Through TWO Vertical DuctsAIR from Other Indoor Spaces RXWGRRUV6HHLJXUHSignage Installation of Carbon Monoxide DetectorsCommonwealth of Massachusetts Inspection Approved Carbon Monoxide DetectorsGeneral Venting Instructions Venting InstallationPower Vent Configuration General Venting InformationINSPECT/ADJUST Intake AIR TEE Fitting Adjustment ProcedureHCG3 100T 199 & SUF 250 Intake AIR Connection Venting Requirements Venting Installation Sequence Power Vent InstallationDirect Vent Installation Pipe Field Supplied Installed Intake AIRField Supplied Factory Installed Intake AIR Connection Remove for Direct VentVertical Termination Installation Field Supplied STRAP/SUPPORT Vertical Terminations InstallationVertical Termination Direct Vent Vertical Terminations Flat Roof ClearanceOHDVWLQFKHV FP 6HHLJXUH Sidewall Termination InstallationSidewall Termination Installation SDVVWKURXJKWKHZDOOVDPHORFDWLRQ Concentric Termination InstallationConcentric Termination Flat Roof Clearance QDWLRQDOFRGHVPXVWEHPDLQWDLQHGInch Concentric Termination KIT Inch Concentric Termination InstallationEight Concentric Terminations TWO Concentric TerminationsThree Concentric Terminations Four Concentric TerminationsJURXSVGHSHQGLQJRQDYDLODEOHVSDFH Multiple Concentric Termination ArrangementsTwo Concentric Terminations Eight Concentric TerminationsPower Vent Horizontal Venting ArrangementsDirect Vent Horizontal Direct Vent Vertical Vent Horizontal Intake Direct Vent Horizontal Vent Vertical IntakeDirect Vent Horizontal Concentric Power Vent Termination Clearances Sidewall Power VentDirect Vent Termination Clearances Sidewall Direct VentInstallation Instructions Water Heater InstallationCondensate Drain Installation Installation NotesSupply GAS Line Sizing Metric Units Supply GAS Line InstallationGAS Line Sizing Supply GAS Line Sizing U. S. UnitsGAS Line Leak Testing PurgingGAS Line Connection Connecting An External Supervisory Control Electrical WiringPower Supply Connections ENABLE/DISABLE CircuitWater Potable Heating and Space Heating Water Piping DiagramsWater Line Connections Valve Discharge Pipe Thermometers not SuppliedThermostat Control Temperature RegulationHigh Temperature Limit Control ECO High Temperature ApplicationsMenu Help Control System OperationOverview Control System NavigationIcon Description Status IconsMenu Description Operating StatesState Description Control System MenusUser Settings & Control System Menus Update CancelBack Help Change Back Help Hrs 22 mins Elapsed TimeDay 0 hrs 0 mins Burner On TimeYesno Back AdvancedView Back Help ECOYour Company Name Here UpdateSelect Back Help NameStart UP Prior to Start UPInitial Start UP GAS Valve TOP Detail View GAS Valve / Venturi Assembly TOP ViewGAS Valve TOP View GAS Valve Side ViewPDQXDOIRUIXUWKHUDVVLVWDQFH Supply GAS Pressure AdjustmentMultiple Water Heater Installations Manifold GAS Pressure AdjustmentFLUFXPVWDQFHV Checking the Firing Rate High Altitude Installations‡  VHFRQGVLQRQHKRXU To Turn OFF GASDQGRSHUDWLQJWKHZDWHUKHDWHU On/Off SwitchLighting the Water Heater Lighting & Operation LabelsTank Temperature 103F Operating Set Point 120F Do not TRY to Light the Burner by HandMenu Help Installation Checklist Sequence of Operation TroubleshootingYES no Sequence of Operation Flow ChartMomentary Ignition Operational ProblemsInstallation Errors Rough STARTING, Rough OperationFault and Alert Conditions Possible Causes CHECK/REPAIR Displayed FAULT/ALERT Message Back AdvancedHeater Information menu see Heater Information on No Anode Voltage Blower Prover FailureMaintenance General Maintenance ScheduleDraining and Flushing Manual Lime Scale Removal Filling the Water HeaterSediment Removal Lime Scale RemovalVent System Powered Anode RodsDrain Valve and Access Panels TEMPERATURE-PRESSURE Relief Valve TestChanging Number of Ignition Trials Before Lock OUT DiagramsS1 Dipswitch CCB Central Control Board LayoutGround VAC Neutral VAC HOT HCG3 120 & 150 Wiring DiagramTransformer 50VA ON/OFFHCG3 199 & 250 Wiring Diagram 11 on J6 PlugGround Strip Burner Ground Inside CCB Burner Bolt Enclosure Circulation Pump Wiring Diagrams Finished Floor Cold Water Supply Expansion Tank Water Piping DiagramsLine Temperature Control HOT Water Return HOT Water Outlet Pipe T&P to Open Drain6HH0LLQJ9DOYHVRQSDJH 6HH&ORVHG6\VWHPVDQG7KHUPDOSDQVLRQRQSDJH6HHDWHU/LQH&RQQHFWLRQVRQSDJH HIRUHLQVWDOODWLRQRIZDWHUSLSLQJUHYLHZWKHIROORZLQJStorage Tank HOT Water OutletPipe T&P to Open Drain Finished Floor Storage Tanktemperature Water Piping Diagrams Open Drain HOT Water Return Cold Water Supply Expansion Tank Temperature & Pressure HOT Water Outlet Pipe T&P to Open Drain Finished FloorFull Port Ball Valve 6&XVWRPHUV Page ZZZDPHULFDQZDWHUKHDWHUFRP

AHCG/HCG3 60T 120 - AHCG3/HCG3 100T 250, Commercial Gas Water Heaters specifications

American Water Heater's Commercial Gas Water Heaters, particularly the AHCG/HCG3 60T 120 and AHCG3/HCG3 100T 250 models, stand out in the market for their impressive performance and reliable efficiency. Designed to meet the demanding needs of commercial applications, these gas water heaters provide an optimal solution for businesses requiring consistent hot water supply.

One of the main features of the AHCG/HCG3 series is its exceptional heat capacity. The models are engineered to deliver high recovery rates, ensuring that adequate hot water is available even during peak demand periods. The AHCG/HCG3 60T 120 can yield a robust output, ideal for smaller to medium-sized facilities, while the AHCG3/HCG3 100T 250 is designed for larger operations that require enhanced capacity.

These water heaters incorporate innovative technologies to maximize efficiency. The use of a high-efficiency burner system significantly reduces gas consumption, earning these models an Energy Factor rating that complies with modern energy standards. Additionally, the inclusion of a direct vent design allows for safe and efficient exhaust management, further promoting the energy-saving capabilities of these units.

The design of these commercial water heaters prioritizes durability and longevity. Constructed with heavy-duty components, including a corrosion-resistant water tank, these models are built to last, reducing the need for frequent replacements and maintenance. They also feature an advanced control system that monitors and adjusts the operation for optimal performance, enhancing user experience while decreasing operational costs.

Another notable characteristic of the AHCG/HCG3 series is their flexibility in installation. Both the 60T 120 and the 100T 250 models offer various venting options, which means they can easily fit into the existing infrastructure of many commercial facilities. This versatility facilitates a seamless integration process, saving time and resources during installation.

With a commitment to providing effective hot water solutions, American Water Heater continues to innovate, making the AHCG/HCG3 series a valuable addition to any commercial establishment. From restaurants to laundromats and beyond, these gas water heaters deliver reliable performance, ensuring that businesses can operate smoothly and efficiently.