VENT PIPE SYSTEM

WARNING

Carbon Monoxide Warning

Follow all the local and state codes or, in the absence of local and state codes, the “National Fuel Gas Code”, ANSI Z223.1 (NFPA 54)- latest edition to properly install vent system.

Failure to do so can result in death, explosion, or carbon monoxide poisoning.

Venting

This water heater has a direct vent system in which all air for combustion is taken from the outside atmosphere and all combustion products are discharged to the outdoors.

This water heater must be properly vented for removal of exhaust gases to the outside atmosphere. Correct installation of the vent pipe system is mandatory for the safe and efficient operation of this water heater and is an important factor in the life of the unit.

Vent pipe installation must be performed in accordance with state and local codes, or in the absence of such, the National Fuel Gas Code, NFPA 54, ANSI Z223.1-current edition. IMPORTANT: Check to make sure the vent pipe is not blocked in any way.

NOTE: Do not common vent this water heater with any other appliance. Do not install in the same chase or

chimney with a metal or high-temperature plastic from another gas or fuel burning appliance.

When assembling the air inlet and vent outlet pipe system, BOTH pipe diameters MUST be the same size. For example, if a 2 inch diameter pipe is used on the air inlet pipe then a 2 inch diameter pipe MUST be used on the vent outlet. This requirement also applies to 3 inch diameter piping configurations.

Vent Pipe Material

The following plastic materials may be used for both the combustion air inlet and exhaust outlet piping subject to state and local codes:

2 or 3 inch Schedule 40 PVC or ABS

2 or 3 inch Schedule 40 or 80 CPVC

DWV Pipe is acceptable

NOTE: Use only solid (not foam core) piping. Plastic pipe and fittings are available through most plumbing suppliers. Always check the marking on the pipe to make sure you are using the correct material.

Vent Pipe Connection to Blower

A 3”x2” condensate drain coupler is supplied with every

40-42K BTU model to connect either 2” or 3” venting to the blower. A 3” condensate drain coupler is supplied with every 50-60K BTU model to connect 3” venting to the blower. IMPORTANT: These connections must be properly sealed to prevent the leakage of the products of combustion into the living area. If needed 3”x2” & 3” condensate drain couplers are available through the Parts Department for new installations or retrofits where condensate may run back to the blower.

7

Image 7
Contents Flammable Vapor Ignition Resistant Compliant Installation Instructions Use & Care GuideTable Of Contents Water Heater SafetyUnpacking the Water Heater Installing Your GAS Water HeaterConsumer Information Consumer ResponsibilitiesSite Location Location RequirementsFire or Explosion Hazard State of California Clearances and AccessibilityGas Pressure Gas Pressure TestingGas Supply Gas RequirementsVent Pipe Connection to Blower Vent Pipe SystemVenting Vent Pipe MaterialVent Pipe Length Vent Pipe InstallationVent Termination Locations US InstallationsConcentric Vent Terminations INLET/OUTLET Vent TerminationsStandard Horizontal Termination Vertical TerminationWater System Piping Piping InstallationClosed System/Thermal Expansion Temperature and Pressure Relief ValveValve and Pipe Insulation Some Models Electrical Connections Wiring DiagramInstallation Checklist Missing or damaged Operating Your Water HeaterLighting Instructions Replace viewport if glass isWater Heater Operation Water Temperature RegulationTemperature limiting valves are available G. Bottled Propane ModelsWater Heater Sounds Safety Shut-offOperational Conditions CondensationDraining and Flushing Maintenance of Your Water HeaterRoutine Preventive Maintenance Temperature and Pressure Relief ValveRemoving the Burner from the Manifold Assembly Replacement PartsRemoving and Replacing the Gas Control Valve/Thermostat Replacing the Manifold AssemblyLED Status Problem Solution TroubleshootingSee Anode ROD/WATER Above 170FODOR, Section Repair Parts List Repair Parts IllustrationListed Parts Kits and Illustrations

40-42K BTU, 50-60K BTU specifications

When it comes to reliable water heating solutions, American Water Heater Company stands at the forefront of the industry, offering a range of models, including those with 50-60K BTU and 40-42K BTU capacity. These water heaters are engineered to deliver consistent and efficient hot water supply for residential and commercial applications.

One of the standout features of American water heaters is their advanced insulation technology. These units come with high-density foam insulation that minimizes heat loss, ensuring that the water remains hot for extended periods. This feature not only improves energy efficiency but also reduces operating costs for users.

For the 50-60K BTU models, American Water Heater employs a powerful gas burner system that offers quick recovery rates, making it an ideal choice for larger households or businesses that require a high volume of hot water. This capability ensures that there is always an adequate supply of hot water for multiple simultaneous tasks, such as showering, washing dishes, and laundry.

On the other hand, the 40-42K BTU models provide an excellent balance between performance and energy conservation, making them suitable for medium-sized homes. These units are equipped with electronic ignition systems that enhance reliability and safety while providing a user-friendly experience. The electronic igniter eliminates the need for a pilot light, reducing gas consumption and increasing energy efficiency.

Durability is another hallmark of American Water Heater products. Constructed with robust materials, these units are designed to withstand the rigors of daily use while also resisting corrosion. This ensures a longer lifespan and reduces maintenance costs over time.

Safety features are also a priority for American Water Heater. Many models incorporate advanced safety systems, including temperature and pressure relief valves, ensuring user safety and compliance with building codes.

In terms of technology, American Water Heaters often include features that promote user convenience, such as programmable thermostats and easy-to-read digital displays. These allow homeowners to customize their hot water settings to fit their lifestyle, optimizing both comfort and energy efficiency.

Overall, American Water Heater’s 50-60K BTU and 40-42K BTU models epitomize quality, efficiency, and innovation in water heating technology, making them a preferred choice for consumers seeking effective and dependable hot water solutions.