American Water Heater 50-60K BTU, 40-42K BTU Troubleshooting, LED Status Problem Solution

Page 21

TROUBLESHOOTING

LED STATUS

PROBLEM

 

SOLUTION

 

An open earth ground circuit to the ignition

1.

Check that the earth ground connection is

 

system.

 

properly connected.

 

 

2.

Check that the earth ground conductor on the

 

 

water heater is properly connected.

 

Wiring error or a high resistance to earth

1.

Check for proper connection of line neutral and

 

ground.

 

hot wires.

 

 

2.

Check that the water heater is securely

 

 

 

connected to earth ground.

 

Pressure switch remained closed longer than 5

1.

Pressure switch wiring is incorrect.

 

seconds after the call for heat began.

2.

Replace pressure switch.

 

Pressure switch remained open longer than

1.

Pressure switch wiring is incorrect.

 

5 seconds after the combustion blower was

2.

Pressure Switch tubing is not connected correctly.

 

energized.

3. Air intake or exhaust obstructed.

 

Error in the hot surface igniter circuit.

1.

Check that all wiring is correct and secure.

 

 

2.

Replace hot surface igniter.

 

System in lockout.

1.

Gas supply is off or too low to operate.

 

 

2

Hot surface igniter not positioned correctly.

 

 

3.

Low voltage to the water heater.

 

 

4.

Electric polarity to unit is incorrect - test and cor-

 

 

rect.

 

Problem in the gas valve driver circuit.

1. Turn power to the water heater off for 10 seconds

 

 

 

and then back on.

 

 

2.

Replace gas control valve.

 

Problem with the internal circuit.

1. Turn power to the water heater off for 10 seconds

 

 

 

and then back on.

 

 

2.

Replace gas control valve.

 

Problem with the internal circuit.

1. Turn power to the water heater off for 10 seconds

 

 

 

and then back on.

 

 

2.

Replace gas control valve.

 

Flame signal sensed out of proper sequence.

1.

Replace gas control valve.

 

 

 

 

 

ECO activated.

1.

Replace gas control valve.

 

 

 

 

 

One of the temperature adjust buttons stuck

1.

Press and release each of the buttons once.

 

closed.

2.

Replace gas control valve.

 

Water temperature sensor is either open or

1.

Check that all wiring is correct and secure.

 

short circuited.

2.

Replace gas control valve.

21

Image 21
Contents Flammable Vapor Ignition Resistant Compliant Installation Instructions Use & Care GuideTable Of Contents Water Heater SafetyConsumer Information Installing Your GAS Water HeaterConsumer Responsibilities Unpacking the Water HeaterLocation Requirements Site LocationFire or Explosion Hazard State of California Clearances and AccessibilityGas Supply Gas Pressure TestingGas Requirements Gas PressureVenting Vent Pipe SystemVent Pipe Material Vent Pipe Connection to BlowerVent Pipe Length Vent Pipe InstallationVent Termination Locations US InstallationsStandard Horizontal Termination INLET/OUTLET Vent TerminationsVertical Termination Concentric Vent TerminationsWater System Piping Piping InstallationTemperature and Pressure Relief Valve Closed System/Thermal ExpansionValve and Pipe Insulation Some Models Electrical Connections Wiring DiagramInstallation Checklist Lighting Instructions Operating Your Water HeaterReplace viewport if glass is Missing or damagedTemperature limiting valves are available Water Temperature RegulationG. Bottled Propane Models Water Heater OperationOperational Conditions Safety Shut-offCondensation Water Heater SoundsRoutine Preventive Maintenance Maintenance of Your Water HeaterTemperature and Pressure Relief Valve Draining and FlushingRemoving the Burner from the Manifold Assembly Replacement PartsRemoving and Replacing the Gas Control Valve/Thermostat Replacing the Manifold AssemblyLED Status Problem Solution TroubleshootingAbove 170F See Anode ROD/WATERODOR, Section Repair Parts List Repair Parts IllustrationListed Parts Kits and Illustrations

40-42K BTU, 50-60K BTU specifications

When it comes to reliable water heating solutions, American Water Heater Company stands at the forefront of the industry, offering a range of models, including those with 50-60K BTU and 40-42K BTU capacity. These water heaters are engineered to deliver consistent and efficient hot water supply for residential and commercial applications.

One of the standout features of American water heaters is their advanced insulation technology. These units come with high-density foam insulation that minimizes heat loss, ensuring that the water remains hot for extended periods. This feature not only improves energy efficiency but also reduces operating costs for users.

For the 50-60K BTU models, American Water Heater employs a powerful gas burner system that offers quick recovery rates, making it an ideal choice for larger households or businesses that require a high volume of hot water. This capability ensures that there is always an adequate supply of hot water for multiple simultaneous tasks, such as showering, washing dishes, and laundry.

On the other hand, the 40-42K BTU models provide an excellent balance between performance and energy conservation, making them suitable for medium-sized homes. These units are equipped with electronic ignition systems that enhance reliability and safety while providing a user-friendly experience. The electronic igniter eliminates the need for a pilot light, reducing gas consumption and increasing energy efficiency.

Durability is another hallmark of American Water Heater products. Constructed with robust materials, these units are designed to withstand the rigors of daily use while also resisting corrosion. This ensures a longer lifespan and reduces maintenance costs over time.

Safety features are also a priority for American Water Heater. Many models incorporate advanced safety systems, including temperature and pressure relief valves, ensuring user safety and compliance with building codes.

In terms of technology, American Water Heaters often include features that promote user convenience, such as programmable thermostats and easy-to-read digital displays. These allow homeowners to customize their hot water settings to fit their lifestyle, optimizing both comfort and energy efficiency.

Overall, American Water Heater’s 50-60K BTU and 40-42K BTU models epitomize quality, efficiency, and innovation in water heating technology, making them a preferred choice for consumers seeking effective and dependable hot water solutions.