A.O. Smith XDVS, GDVS, GDVH owner manual

Page 12

4.Using the tube of sealant supplied, run an ample amount around the oval flare of the jacket.

8.Making sure the 6” diameter elbow is centered around the 3” diameter flue, secure the 6” diameter vent pipe using two sheet metal screws at the connection of the elbow and 6” vertical extension.

FIGURE 37

5.Place the 6” vent section over the 3” flue section. Subtract 3/4” from the X dimension used earlier and this gives the length of the 6” vent extension. Slide the 6” vent extension apart to this dimension and lock it together using the two screws supplied.

FIGURE 38

6.Bend the round end of the 6” vent extension oval at the jacket top and secure it using four sheet metal screws.

FIGURE 41

9.The standard vent kit includes a 6” diameter extension pipe which is used when “E” dimension over 6 1/2”.

FIGURE 42

10.If “E” Dimension is less than 6 1/2” move to next step.

If “E” dimension is over 6 1/2”, assemble the 6” diameter extension pipe to the 6” diameter vent elbow and secure using two sheet metal screws. Using the tube of sealant supplied, run an ample amount around the joint to insure a good seal.

FIGURE 39

7. Place the 3” elbow on the flue extension.

NOTE: Make sure elbow is properly aligned to opening in the outside wall.

Mark the 3” dia. end of the flue extension at the slots the elbow. Using a #22 drill bit, drill holes into the flue extension at the two slots and secure the elbow to the flue extension using the screws provided.

FIGURE 40

FIGURE 43

11.Slide the vent collar (to be installed later) over the 6” vent elbow.

FIGURE 44

12

Image 12
Contents Direct Vent GAS Models Typical Installation Replacement PartsVent KIT Assembly Components External DamageChemical Vapor Corrosion Extended NON-USE PeriodsWater Potable Heating and Space Heating Closed Water SystemGAS Connections Relief Valve VentingVent Pipe Termination Optional Wire Grill Combustion AIR and VentilationVenting Clearances Flue Extensions Possible Extension CombinationsALL Installations Vertical Extension KIT HeightHorizontal Extension KIT Cutting the Opening Through Outside WallStandard Vent KIT Installation #1 Water Heater AttitudePage Equation C a -10 = GallonPage Page Optional Horizontal Vent KIT #900124-7 Installation #3 Page Equation C a 10 = Capacity NaturalInsert the 6 telescoping vent section into the wall Page High Altitude Installations Temperature RegulationValve and Pipe Insulation FillingFor Your Safety Read Before Lighting ForceTemperature & Pressure Relief Valve Pilot and Main BurnerDraining Anode ROD Maintenance CondensationCathodic Protection Anode Troubleshooting Service and Labor Responsibility Claim ProcedureConditions and Exceptions Limitation on Implied WarrantiesPage Page Page Tennessee Waltz PARKWAY, Ashland CITY, TN

GDVH, XDVS, GDVS specifications

A.O. Smith is a leading manufacturer of water heating solutions, renowned for offering innovative products that cater to both residential and commercial needs. Among its impressive lineup, the GDVH, XDVS, and GDVS models stand out, showcasing advanced features and technologies that enhance performance and efficiency.

The A.O. Smith GDVH series is designed for high-efficiency gas water heating. These units come equipped with the latest condensing technology, which allows them to utilize heat that would otherwise be lost in traditional systems. This process results in improved energy efficiency and significant cost savings on energy bills. The GDVH series is also noted for its EcoSmart feature, which adjusts the operational settings according to water usage patterns, further optimizing energy consumption.

The XDVS model, on the other hand, is a testament to A.O. Smith's commitment to durability and performance. Constructed with high-quality materials, the XDVS offers exceptional resistance against corrosion, thereby prolonging the lifespan of the unit. This model features advanced controls that provide real-time diagnostic information, enabling users to monitor performance and schedule maintenance effectively.

The GDVS series bridges the gap between affordability and performance. These water heaters are designed with a user-friendly interface, allowing for simple operation and easy adjustments. The GDVS models utilize a high-efficiency burner system that ensures rapid heating capabilities while keeping energy costs down. Additionally, the units are compact, making them ideal for homes with limited installation space, without compromising on output performance.

All three models incorporate A.O. Smith’s proven heating technologies that prioritize safety and efficiency. They feature advanced flame sensors and integrated safety controls that protect against overheating and ensure reliable operation. Furthermore, these models are compatible with various installation configurations, making them versatile options for diverse applications.

In conclusion, A.O. Smith's GDVH, XDVS, and GDVS water heaters present a blend of cutting-edge technology, rugged durability, and user-friendly features, catering to the needs of modern households and businesses. With energy efficiency as a hallmark of their design, these models not only promise excellent performance but also contribute to sustainable energy usage, making them an ideal choice for eco-conscious consumers.