A.O. Smith GDVH, XDVS, GDVS owner manual Relief Valve, Venting, Vent Pipe Termination

Page 5

Make sure that the outside vents on the supply regulators and the safety vent valves are protected against blockage. These are parts of the gas supply system not the heater. Vent blockage may occur during ice storms.

IT IS IMPORTANT TO GUARD AGAINST CONTROL FOULING FROM CONTAMINANTS IN THE GAS WAYS. SUCH FOULING MAY CAUSE IMPROPER OPERATION, FIRE OR EXPLOSION.

All piping must comply with local codes and ordinances or with the current edition of National Fuel Gas Code (ANSI Z223.1/ NFPA-54) whichever applies.

REFER TO FIGURE 1 FOR CONNECTION DETAILS. BEFORE ATTACHING THE GAS LINE BE SURE THAT ALL GAS PIPE IS CLEAN ON THE INSIDE.

TO TRAP ANY DIRT OR FOREIGN MATERIAL IN THE GAS SUPPLY LINE, A DIRT LEG (SOMETIMES CALLED DRIP LEG) MUST BE INCORPORATED IN THE PIPING, FIGURE 1. The dirt leg must be readily accessible. Install in accordance with recommendations of serving gas supplier. Refer to the latest edition of the National Fuel Gas Code ANSI Z223.1.

To prevent damage, care must be taken not to apply too much torque when attaching gas supply pipe to thermostat gas inlet. The thermostat inlet has a pad for use with a backup wrench.

Apply joint compounds (pipe dope) sparingly and only to the male threads of pipe joints. Do not apply compound to the first two threads. Use compounds resistant to the action of liquefied petroleum gases. Do not use teflon tape on thermostat fittings.

DISCONNECT THE APPLIANCE FROM THE GAS SUPPLY PIPING SYSTEM DURING ANY SUPPLY PRESSURE TESTING EXCEEDING 1/2 PSI (3.5 kPa). GAS SUPPLY LINE MUST BE CAPPED WHEN DISCONNECTED FROM THE HEATER. FOR TEST PRESSURES AT 1/2 PSI (3.5 kPa) OR LESS, THE APPLIANCE NEED NOT BE DISCONNECTED, BUT MUST BE ISOLATED FROM THE SUPPLY PRESSURE TEST BY CLOSING THE MAIN MANUAL GAS VALVE.

BEFORE PLACING THE HEATER IN OPERATION, CHECK FOR GAS LEAKAGE. USE SOAP AND WATER SOLUTION OR OTHER MATERIAL ACCEPTABLE FOR THIS PURPOSE. DO NOT USE MATCHES, CANDLES, FLAME OR OTHER SOURCES OF IGNITION TO LOCATE GAS LEAKS.

RELIEF VALVE

A NEW TEMPERATURE AND PRESSURE RELIEF VALVE COMPLYING WITH THE STANDARD FOR RELIEF VALVES AND AUTOMATIC GAS SHUT OFF DEVICES FOR HOT WATER SUPPLY SYSTEMS, ANSI Z21.22 (CURRENT EDITION) MUST BE INSTALLED IN THE HEATER IN THE MARKED OPENING PROVIDED, SEE FIGURE 1. THE VALVE MUST BE OF A SIZE (INPUT RATING) THAT WILL BE ADEQUATE FOR YOUR SIZE HEATER.

Check the metal tag on the relief valve and compare it to the heater’s rating plate. The pressure rating of the relief valve must

not exceed the working pressure shown on the rating plate of the heater. In addition, the hourly BTU rated temperature steam discharge capacity of the relief valve shall not be less than the input rating of the heater. NO VALVE IS TO BE PLACED BETWEEN THE RELIEF VALVE AND TANK. DO NOT PLUG THE RELIEF VALVE.

The drain line connected to this valve must not contain a reducing coupling or other restriction and must terminate near a suitable drain to prevent water damage during valve operation. The discharge line shall be installed in a manner to allow complete drainage of both the valve and line. DO NOT THREAD, PLUG OR CAP THE END OF THE DRAIN LINE.

VENTING

WARNING

NEVER OPERATE THE HEATER UNLESS IT IS VENTED TO THE OUTDOORS AND HAS ADEQUATE AIR SUPPLY TO AVOID RISKS OF IMPROPER OPERATION, FIRE, EXPLOSION OR ASPHYXIATION.

DO NOT OBSTRUCT THE FLOW OF COMBUSTION AND VENTILATING AIR. ADEQUATE AIR FOR COMBUSTION AND VENTILATION MUST BE PROVIDED FOR SAFE OPERATION.

VENT PIPE TERMINATION

Before installing water heater determine placement of vent pipe termination.

MAKE CERTAIN TO OBSERVE VENT LOCATION LIMITATION, SEE FIGURES 4 & 5.

CAUTION

Use only the vent kit assembly supplied with this water heater or if needed one of the three listed optional flue extensions. See

Figure 10 for possible combinations. VENTING OR TERMINATION WITH ANY OTHER KIT NOT LISTED IS NOT RECOMMENDED AND COULD AFFECT THE SYSTEMS PERFORMANCE AND RESULT IN A SAFETY HAZARD.

WARNING

MINIMUM CLEARANCES BETWEEN THE WATER HEATER AND COMBUSTIBLE AND NONCOMBUSTIBLE CONSTRUCTION ARE: 0 INCHES FROM SIDES, 0 INCHES FROM BACK, 4 INCHES FROM FRONT OF JACKET TO CLOSET DOOR AND 3 INCHES FROM TOP OF JACKET TO COMBUSTIBLE AND NONCOMBUSTIBLE MATERIAL. MINIMUM VENT CLEARANCE: 0 INCHES. PROVIDE 24 INCHES FRONT CLEARANCE FOR SERVICING AND ADEQUATE CLEARANCE BETWEEN THE JACKET TOP & CEILING FOR SERVICING THE FLUE AREA , SEE FIGURES 3 AND 3A.

FIGURE 3

5

Image 5
Contents Direct Vent GAS Models Replacement Parts Typical InstallationExternal Damage Vent KIT Assembly ComponentsChemical Vapor Corrosion Extended NON-USE PeriodsGAS Connections Water Potable Heating and Space HeatingClosed Water System Vent Pipe Termination Relief ValveVenting Venting Clearances Optional Wire GrillCombustion AIR and Ventilation Possible Extension Combinations Flue ExtensionsVertical Extension KIT Height ALL InstallationsHorizontal Extension KIT Cutting the Opening Through Outside WallWater Heater Attitude Standard Vent KIT Installation #1Page Gallon Equation C a -10 =Page Page Optional Horizontal Vent KIT #900124-7 Installation #3 Page Capacity Natural Equation C a 10 =Insert the 6 telescoping vent section into the wall Page Temperature Regulation High Altitude InstallationsValve and Pipe Insulation FillingForce For Your Safety Read Before LightingDraining Temperature & Pressure Relief ValvePilot and Main Burner Cathodic Protection Anode Anode ROD MaintenanceCondensation Troubleshooting Claim Procedure Service and Labor ResponsibilityConditions and Exceptions Limitation on Implied WarrantiesPage Page Page Tennessee Waltz PARKWAY, Ashland CITY, TN

GDVH, XDVS, GDVS specifications

A.O. Smith is a leading manufacturer of water heating solutions, renowned for offering innovative products that cater to both residential and commercial needs. Among its impressive lineup, the GDVH, XDVS, and GDVS models stand out, showcasing advanced features and technologies that enhance performance and efficiency.

The A.O. Smith GDVH series is designed for high-efficiency gas water heating. These units come equipped with the latest condensing technology, which allows them to utilize heat that would otherwise be lost in traditional systems. This process results in improved energy efficiency and significant cost savings on energy bills. The GDVH series is also noted for its EcoSmart feature, which adjusts the operational settings according to water usage patterns, further optimizing energy consumption.

The XDVS model, on the other hand, is a testament to A.O. Smith's commitment to durability and performance. Constructed with high-quality materials, the XDVS offers exceptional resistance against corrosion, thereby prolonging the lifespan of the unit. This model features advanced controls that provide real-time diagnostic information, enabling users to monitor performance and schedule maintenance effectively.

The GDVS series bridges the gap between affordability and performance. These water heaters are designed with a user-friendly interface, allowing for simple operation and easy adjustments. The GDVS models utilize a high-efficiency burner system that ensures rapid heating capabilities while keeping energy costs down. Additionally, the units are compact, making them ideal for homes with limited installation space, without compromising on output performance.

All three models incorporate A.O. Smith’s proven heating technologies that prioritize safety and efficiency. They feature advanced flame sensors and integrated safety controls that protect against overheating and ensure reliable operation. Furthermore, these models are compatible with various installation configurations, making them versatile options for diverse applications.

In conclusion, A.O. Smith's GDVH, XDVS, and GDVS water heaters present a blend of cutting-edge technology, rugged durability, and user-friendly features, catering to the needs of modern households and businesses. With energy efficiency as a hallmark of their design, these models not only promise excellent performance but also contribute to sustainable energy usage, making them an ideal choice for eco-conscious consumers.