A.O. Smith 650, GB/GW-300, 500, 750 SERIES warranty NEW Boiler Limited Warranty

Page 23

NEW BOILER LIMITED WARRANTY

A. O. Smith Corporation, the warrantor, extends the following LIMITED WARRANTY to the owner of this hydronic boiler:

1.If within TEN years after initial installation of the boiler, the heat exchanger shall prove upon examination by the warrantor to be defective in material or workmanship, the warrantor, at his option, will exchange or repair such part or portion. This term is reduced to FIVE years if this boiler is used for volume hot water supply purposes other than hydronic space heating.

a.This warranty is extended to the owner for all other parts or portion during the FIRST year following initial installation of this boiler.

b.The warranty on the repair or replacement of the part or portion will be limited to the unexpired term of the original warranty.

2.CONDITIONS AND EXCEPTIONS

This warranty shall apply only when the boiler is installed in accordance with local plumbing and building codes, ordinances and regulations, the printed instructions provided with it and good industry practices. In addition, an appropriately sized safety relief valve certified to the ASME Boiler and Pressure Vessel Code must have been installed and fresh water used for filling and makeup purposes;

a.This warranty shall apply only when the boiler is used:

(1)at temperatures not exceeding the maximum setting of its operative and/or high limit control;

(2)at water pressure not exceeding the working pressure shown on the boiler;

(3)when filled with boiler water, free to circulate at all times and with the heat exchanger free of damaging scale deposits;

(4)in a noncorrosive and non-contaminated atmosphere;

(5)in the United States, its territories or possessions, and Canada;

(6)at a water velocity flow rate, not exceeding or below the Boiler's designed flow rates;

b.Any accident to the boiler, any misuse, abuse (including freezing) or alteration of it, any operation of it in a modified form will void this warranty.

3.SERVICE AND REPAIR EXPENSE

Under this limited warranty the warrantor will provide only a replacement part. The owner is responsible for all other costs. Such costs may include but are not limited to:

a.Labor charges for service removal, repair or reinstallation of the component part;

b.Shipping, delivery, handling, and administrative charges for forwarding the replacement part from the nearest distributor and returning the claimed defective part to such distributor.

c.All cost necessary or incidental for any material and/or permits required for installation of the replacement.

4.LIMITATIONS ON IMPLIED WARRANTIES

Implied warranties, including any warranty of merchantability imposed on the sale of this boiler under state law are limited to one (1) year duration for the boiler or any of its parts. Some states or provinces do not allow limitations on how long an implied warranty lasts, so the above limitation may not apply to you.

5.CLAIM PROCEDURE

Any claim under the warranty should be initiated with the dealer who sold the boiler, or with any other dealer handling the warrantor’s products. If this is not practical, the owner should contact:

U.S. Customers

Canadian Customers

A. O. Smith Water Products Company

A. O. Smith Enterprises Ltd.

500 Tennessee Waltz Parkway,

P. O. Box, 310 - 768 Erie Street

Ashland City, TN 37015

Stratford, Ontario N5A 6T3

Telephone: 800 323-2636

Telephone: (519) 271-5800

a.The warrantor will only honor replacement with identical or similar parts thereof which are manufactured or distributed by the warrantor.

b.Dealer replacements are made subject to in-warranty validation by warrantor.

6.DISCLAIMERS

NO OTHER EXPRESS WARRANTY HAS BEEN OR WILL BE MADE ON BEHALF OF THE WARRANTOR WITH RESPECTTO THE MERCHANTABILITY OF THE BOILER OR THE INSTALLATION, OPERATION, REPAIR OR REPLACEMENT OF THE BOILER. THE WARRANTOR SHALL NOT BE RESPONSIBLE FOR WATER DAMAGE, LOSS OF USE OF THE UNIT, INCONVENIENCE, LOSS OR DAMAGE TO PERSONALPROPERTY OR OTHER CONSEQUENTIAL DAMAGE. THE WARRANTOR SHALL NOT BE LIABLE BY VIRTUE OF THIS WARRANTY OR OTHERWISE FOR DAMAGE TO ANY PERSONS OR PROPERTY, WHETHER DIRECT OR INDIRECT,AND WHETHERARISING IN CONTRACT OR TORT.

a.Some states or provinces do not allow the exclusion or limitation of the incidental or consequential damage, so the above limitations or exclusions may not apply to you.

b.This warranty gives you specific legal rights, and you may also have other rights which vary from state to state or province to province.

Fill in the following for your own reference. Keep it. Registration is not a condition of warranty. The model and serial number are found on the boiler’s rating plate.

Owner_________________________________________________________________________________________________________________________

Installation Address____________________________________________________________________________________________________

City and State or Province_______________________________________________________Postal/Zip Code___________________________

DateInstalled_____________________________Model No.____________________________Serial No._________________________________

Dealer’s Name________________________________________________________________________________________________________

Dealer’s Address______________________________________________________________PhoneNo.________________________________

FILL IN WARRANTYAND KEEP FOR FUTURE REFERENCE

23

Image 23
Contents 14-18 Series 400, 401, 402, 403, 404Lighting Instructions for the GB/W 300 through 750 models Risk of Scalds Lighting InstructionsInputs To CCB and FCB Burner SystemCCB Drawing #211758 FCB Drawing #211759 PDB Drawing #211760 Igniters CCB/FCB Indicator Lamps & FusesLine Polarity Indicator & Fuse Protection Outputs from CCB and FCBsGB/LB FCB Eight position DipswitchStages 1 and 2 will turn on in sequence from 1 to Temperature Setpoints System Control AlgorithmUIM Operating Procedures Description of CCB control states Idle State Description of FCB control statesOperating Differential Setpoint Operating SetpointConnection Diagram Drawing #211769 Page UIM Touch Switches Soft Fault Displayed Description Red LED LockoutHard See below Other troubleshooting hints Page Page Page NEW Boiler Limited Warranty

500, 750 SERIES, 650, GB/GW-300 specifications

The A.O. Smith GB/GW-300, 650, 750 Series, and 500 represent a cutting-edge line of commercial water heaters designed to meet the diverse needs of various applications. These models are highly regarded for their advanced features, robust construction, and reliable performance, making them ideal for businesses such as restaurants, hotels, and industrial facilities.

One of the main features of the A.O. Smith GB/GW series is its high-efficiency design. These water heaters are built with advanced insulation and heat exchanger technology, which contribute to reduced energy consumption and lower operating costs. The products achieve notable energy efficiency ratings, ensuring that businesses can maintain their hot water supply without incurring excessive utility bills.

The GB/GW series also incorporates a user-friendly digital control system. This technology allows operators to monitor and adjust settings easily, providing real-time feedback on temperature and energy consumption. This level of control enhances operational efficiency and ensures hot water is always available when needed.

Another significant characteristic of the A.O. Smith GB/GW series is its durable construction. The units are designed with high-quality materials that resist corrosion and wear, extending their operational lifespan. The stainless steel tanks and heat exchangers are engineered to withstand high temperatures and pressure, making them reliable even in demanding environments.

Moreover, safety features are paramount in the design of these water heaters. The series includes multiple safety mechanisms, such as high-temperature limit switches and pressure relief valves, ensuring the safe operation of the unit at all times. This not only protects the equipment but also guarantees the safety of personnel using hot water.

The GB/GW series ranges in capacity, accommodating different sizes of operations. From the compact and efficient 300 model to the larger 650 and 750 units, the series offers flexibility to suit various demands. The 500 model strikes a balance between capacity and efficiency, making it a popular choice for medium-sized establishments.

In summary, the A.O. Smith GB/GW-300, 650, 750 Series, and 500 are exemplary choices for commercial water heating solutions. Their combination of efficiency, advanced technology, durable design, and comprehensive safety features ensures that businesses have access to reliable hot water, ultimately supporting their operational needs and enhancing service delivery.