A.O. Smith 185874-001, FMV-40, FMV-30, FMV-50 instruction manual

Page 15

9.Remove flange nuts holding inner door in place with 3/8” nut driver, see Figure 13.

15.Remove the Phillips-head screw holding the pilot bracket to the burner head, see Figure 16.

FIGURE 13.

10.Loosen flare nut “T” holding thermocouple to bottom of gas valve with 3/8” open-end wrench and pull down to remove, see Figure

14.

11.Loosen flare nut “P” holding pilot line to bottom of gas valve with 7/16” open-end wrench and pull tube down to remove, see

Figure 14.

12.Loosen flange nut “B” holding burner tube to bottom of gas valve with 3/4” open-end wrench and pull down to remove, see Figure

14.

FIGURE 16.

16.Remove the two Phillips-head screws holding the natural burner head to the burner tube assembly, see Figure 17.

17.Using 3/8” boxed-end wrench remove the natural gas burner orifice “O” from the burner tube. Install burner orifice marked

“LP” and tighten securely, see Figure 17.

18.Locate and install the propane burner head to the burner tube using the two Phillips-head screws, see Figure 17.

FIGURE 14.

13.Grasp burner tube and remove burner assembly through inner door opening.

14.To remove the natural gas pilot assembly, remove the Phillips- head screw holding the TCO bracket to the burner tube bracket, see Figure 15.

FIGURE 15.

FIGURE 17.

19.Push the natural gas pilot assembly grommet out of the inner door towards the combustion chamber.

20.To install the propane pilot assembly, put the igniter wire, thermostat lead, and pilot tube through the inner door hole. Reinstall the Phillips-head screw securing the TCO bracket to the burner tube. Reinstall the Phillips-head screw securing the pilot assembly to the burner head bracket.

21.Push the grommet into the inner door hole making sure the door fits into the groove in the grommet.

22.Reinstall the burner assembly through the door opening being careful not to damage the door gasket on the studs. Position end of burner tube inside bracket as shown in Figure 18.

FIGURE 18.

15

Image 15
Contents Residential GAS Water Heaters Important Definitions Safe INSTALLATION, USE and ServiceGeneral Safety Introduction Table of ContentsRobertshaw Typical InstallationsInstall PER Local Codes WHITE-RODGERSHotter Water can Scald Facts to Consider About the Location Locating the NEW Water HeaterInsulation Blankets Water Piping Installing the NEW Water HeaterSecuring Water Heater to Floor and Wall Valve and Pipe InsulationTemperature-Pressure Relief Valve Water Piping Pressure TestOr Property Damage Filling the Water Heater Venting Draft Hood InstallationGas Piping Sediment Traps GAS Piping with Flexible ConnectorPage Page Page Page WHITE-RODGERS GAS Valve Robertshaw GAS Valve Before Lighting the Pilot Installation ChecklistRobertshaw Temperature Adjustment Dial Temperature RegulationFor Your Information Start UP ConditionsOperational Conditions AIR in HOT Water Faucets High Water Temperature Shut OFF SystemBurner Inspection Periodic MaintenanceBurner Cleaning Venting System InspectionTemperature-Pressure Relief Valve Operation Anode ROD InspectionDraining Service Drain Valve Washer ReplacementLeakage Checkpoints This is a Repair Parts LIST, not a Packing List 30 & 40 Gallon Repair Parts ListWHITE-RODGERS Burner Assembly Robertshaw Burner Assembly Thermostat ShieldGallon Repair Parts List Problem Cause Solution Troubleshooting Guidelines