LEAKAGE CHECKPOINTS

Read this manual first. Then before checking the water heater make sure the gas supply has been turned “OFF”, and never turn the gas “ON” before the tank is completely full of water.

A.Water at the draft hood is water vapor which has condensed out of the combustion products. This is caused by a problem in the vent. Contact the gas utility.

B.*Condensation may be seen on pipes in humid weather or pipe connections may be leaking.

C.*The anode rod fitting may be leaking.

D.Small amounts of water from temperature-pressure relief valve may be due to thermal expansion or high water pressure in your area.

E.*The temperature-pressure relief valve may be leaking at the tank fitting.

F.Water from a drain valve may be due to the valve being slightly opened.

G.*The drain valve may be leaking at the tank fitting.

H.Combustion products contain water vapor which can condense on the cooler surfaces of the tank. Droplets form and drip onto the burner or run on the floor. This is common at the time of start-up after installation and when incoming water is cold.

I.Water in the water heater bottom or on the floor may be from condensation, loose connections, or the relief valve. DO NOT replace the water heater until a full inspection of all possible water sources is made and necessary corrective steps taken.

Leakage from other appliances, water lines, or ground seepage should also be checked.

*To check where threaded portion enters tank, insert cotton swab between jacket opening and fitting. If cotton is wet, follow

“Draining” instructions in the “Periodic Maintenance” section and then remove fitting. Put pipe dope or Teflon tape on the threads and replace. Then follow “Filling the Water Heater” instructions in the “Installing the New Water Heater” section.

28

Image 28
Contents Residential GAS Water Heaters Safe INSTALLATION, USE and Service Important DefinitionsGeneral Safety Table of Contents IntroductionTypical Installations Install PER Local CodesWHITE-RODGERS RobertshawHotter Water can Scald Locating the NEW Water Heater Facts to Consider About the LocationInsulation Blankets Installing the NEW Water Heater Securing Water Heater to Floor and WallValve and Pipe Insulation Water PipingWater Piping Pressure Test Temperature-Pressure Relief ValveOr Property Damage Filling the Water Heater Draft Hood Installation VentingGas Piping GAS Piping with Flexible Connector Sediment TrapsPage Page Page Page WHITE-RODGERS GAS Valve Robertshaw GAS Valve Installation Checklist Before Lighting the PilotTemperature Regulation Robertshaw Temperature Adjustment DialStart UP Conditions For Your InformationOperational Conditions High Water Temperature Shut OFF System AIR in HOT Water FaucetsPeriodic Maintenance Burner CleaningVenting System Inspection Burner InspectionAnode ROD Inspection Temperature-Pressure Relief Valve OperationDraining Drain Valve Washer Replacement ServiceLeakage Checkpoints 30 & 40 Gallon Repair Parts List WHITE-RODGERS Burner AssemblyRobertshaw Burner Assembly Thermostat Shield This is a Repair Parts LIST, not a Packing ListGallon Repair Parts List Troubleshooting Guidelines Problem Cause Solution