A.O. Smith FMV-40, FMV-30, FMV-50 AIR in HOT Water Faucets, High Water Temperature Shut OFF System

Page 24

the local water heater supplier or service agency for further information concerning an Anode Replacement Kit and this chlorination treatment.

If the smelly water persists after the anode replacement and chlorination treatment, we can only suggest that chlorination or aeration of the

water supply be considered to eliminate the water problem.

Do not remove the anode leaving the tank unprotected. By doing so, all warranty on the water heater tank is voided.

“AIR” IN HOT WATER FAUCETS

HYDROGEN GAS: Hydrogen gas can be produced in a hot water system that has not been used for a long period of time (generally two weeks or more). Hydrogen gas is extremely flammable and explosive. To prevent the possibility of injury under these conditions, we recommend the hot water faucet, located farthest away, be opened for several minutes before any electrical appliances which are connected to the hot water system are used (such as a dishwasher or washing machine). If hydrogen gas is present, there will probably be an unusual sound similar to air escaping through the pipe as the hot water faucet is opened. There must be no smoking or open flame near the faucet at the time it is open.

HIGH WATER TEMPERATURE SHUT OFF SYSTEM

This water heater is equipped with an automatic gas Shut-off system. This system works when high water temperatures are present. Turn “OFF” the entire gas supply to the water heater. The high temperature Shut-off is built into the gas control valve. It is non-resettable. If the high temperature Shut-off activates, the gas control valve must be replaced. Contact your gas supplier or service agency.

24

Image 24
Contents Residential GAS Water Heaters Safe INSTALLATION, USE and Service Important DefinitionsGeneral Safety Table of Contents IntroductionTypical Installations Install PER Local CodesWHITE-RODGERS RobertshawHotter Water can Scald Locating the NEW Water Heater Facts to Consider About the LocationInsulation Blankets Installing the NEW Water Heater Securing Water Heater to Floor and WallValve and Pipe Insulation Water PipingTemperature-Pressure Relief Valve Water Piping Pressure TestOr Property Damage Filling the Water Heater Draft Hood Installation VentingGas Piping GAS Piping with Flexible Connector Sediment TrapsPage Page Page Page WHITE-RODGERS GAS Valve Robertshaw GAS Valve Installation Checklist Before Lighting the PilotTemperature Regulation Robertshaw Temperature Adjustment DialFor Your Information Start UP ConditionsOperational Conditions High Water Temperature Shut OFF System AIR in HOT Water FaucetsPeriodic Maintenance Burner CleaningVenting System Inspection Burner InspectionTemperature-Pressure Relief Valve Operation Anode ROD InspectionDraining Drain Valve Washer Replacement ServiceLeakage Checkpoints 30 & 40 Gallon Repair Parts List WHITE-RODGERS Burner AssemblyRobertshaw Burner Assembly Thermostat Shield This is a Repair Parts LIST, not a Packing ListGallon Repair Parts List Troubleshooting Guidelines Problem Cause Solution