WARNING: DO NOT
TROUBLESHOOTING
For your safety, water heater service should be performed only by a qualified service technician.
Read the GENERAL SAFETY INFORMATION section first.
PROBLEM |
| POSSIBLE MALFUNCTION | SERVICE TO BE PERFORMED | |||
|
|
|
|
| ||
|
| 1) Blower will not run |
|
| ||
|
| A) | “ON/OFF” control switch turned off | Turn switch to the “ON” position. | ||
|
| B) | Blower unplugged | Plug blower back into 115 vac. outlet. | ||
|
| C) | No power at outlet | Repair service to outlet. | ||
|
| D) | “ON/OFF” switch defective | Replace switch. | ||
|
| E) | Control harness defective | Replace control harness. |
| |
|
| F) | Blower motor defective | Replace blower and motor. | ||
|
| 2) Blower running, burner not on | Replace switch. | |||
|
| A) | Fan not running fast enough to close | Check for low voltage, less than 102 vac., have | ||
|
|
| air switch contacts | service checked and repaired. | ||
|
| B) | Air pressure switch defective | Replace switch. | ||
|
| C) | Gas valve defective | Replace gas valve. | ||
|
| D) | Control harness defective | Replace harness. | ||
NOTENOUGHOR | E) | Igniter defective | Replace igniter. | |||
F) | Unit has completed three trials to light | Reset cycle by turning switch off and then back on. | ||||
NO HOT WATER | ||||||
| and failed | If unit does not light in three trials, call an authorized | ||||
|
|
| ||||
|
|
|
| A.O. Smith service representative. | ||
|
| 3) Thermostat problems |
|
| ||
|
| A) | Thermostat set too low | Turn temperature control higher. | ||
|
| B) | Thermostat or ECO defective | Replace thermostat. | ||
|
| C) | High limit control circuit open | Replace. | ||
|
| 4) Others |
|
| ||
|
| A) | Heater undersized | Reduce hot water use. | ||
|
| B) | Low gas pressure | Contact an authorized A.O.Smith service representative. | ||
|
| C) | Incoming water is unusually cold | Allow more time for heater to | ||
|
| D) | Leaking hot water pipes or fixtures | Have plumber check and repair leaks. | ||
|
| A) | Dirt in burner ports | Turn off heater and gas, clean burner head. | ||
|
| B) | Combustion air path restricted | Clear area around heater and check under heater, | ||
|
|
|
| remove any debris under heater and in openings in | ||
YELLOW FLAME |
|
| bottom cover. | |||
C) | Not enough room air for proper | Refer to installation manual - Confined and Unconfined | ||||
|
|
| combustion | Space statements on page 4 and 5 for required | ||
|
|
|
| openings. | ||
CONDENSATION | A) | Water on the floor under heater | See “CONDENSATION.” | |||
|
| Improperly sealed, hot or cold supply | Turn off heater & water, repair unit. | |||
WATER LEAKS | connections, relief valve, drain valve or | |||||
thermostat threads. |
|
| ||||
|
| Leakage from other appliances or water lines | Inspect other appliances near water heater. | |||
|
| Condensation of flue products | Refer to “CONDENSATION.” | |||
LEAKING T&P VALVE | Thermal expansion in closed water system | Install thermal expansion tank (DO NOT plug T&P valve). | ||||
Improperly seated valve | Checkreliefvalveforproperoperation(DONOTplugT&Pvalve). | |||||
|
| |||||
HOT WATER ODORS | High sulfate or mineral content in water | Drain and flush heater thoroughly, chlorinate, refill | ||||
OR COLOR | supply or iron or sulfate reducing bacteria in | and flush again then chlorinate water supply. | ||||
(Refer to CATHODIC | water supply |
|
| |||
PROTECTION) |
|
|
|
|
17