A.O. Smith BTI-80 warranty Yellow Flame, Or Color

Page 17

WARNING: DO NOT BY-PASSANY CONTROLS TO MAKE HEATER OPERATE. OPERATE ONLYAS WIRED FROM FACTORY.

TROUBLESHOOTING

For your safety, water heater service should be performed only by a qualified service technician.

Read the GENERAL SAFETY INFORMATION section first.

PROBLEM

 

POSSIBLE MALFUNCTION

SERVICE TO BE PERFORMED

 

 

 

 

 

 

 

1) Blower will not run

 

 

 

 

A)

“ON/OFF” control switch turned off

Turn switch to the “ON” position.

 

 

B)

Blower unplugged

Plug blower back into 115 vac. outlet.

 

 

C)

No power at outlet

Repair service to outlet.

 

 

D)

“ON/OFF” switch defective

Replace switch.

 

 

E)

Control harness defective

Replace control harness.

 

 

 

F)

Blower motor defective

Replace blower and motor.

 

 

2) Blower running, burner not on

Replace switch.

 

 

A)

Fan not running fast enough to close

Check for low voltage, less than 102 vac., have

 

 

 

air switch contacts

service checked and repaired.

 

 

B)

Air pressure switch defective

Replace switch.

 

 

C)

Gas valve defective

Replace gas valve.

 

 

D)

Control harness defective

Replace harness.

NOTENOUGHOR

E)

Igniter defective

Replace igniter.

F)

Unit has completed three trials to light

Reset cycle by turning switch off and then back on.

NO HOT WATER

 

and failed

If unit does not light in three trials, call an authorized

 

 

 

 

 

 

 

A.O. Smith service representative.

 

 

3) Thermostat problems

 

 

 

 

A)

Thermostat set too low

Turn temperature control higher.

 

 

B)

Thermostat or ECO defective

Replace thermostat.

 

 

C)

High limit control circuit open

Replace.

 

 

4) Others

 

 

 

 

A)

Heater undersized

Reduce hot water use.

 

 

B)

Low gas pressure

Contact an authorized A.O.Smith service representative.

 

 

C)

Incoming water is unusually cold

Allow more time for heater to re-heat.

 

 

D)

Leaking hot water pipes or fixtures

Have plumber check and repair leaks.

 

 

A)

Dirt in burner ports

Turn off heater and gas, clean burner head.

 

 

B)

Combustion air path restricted

Clear area around heater and check under heater,

 

 

 

 

remove any debris under heater and in openings in

YELLOW FLAME

 

 

bottom cover.

C)

Not enough room air for proper

Refer to installation manual - Confined and Unconfined

 

 

 

combustion

Space statements on page 4 and 5 for required

 

 

 

 

openings.

CONDENSATION

A)

Water on the floor under heater

See “CONDENSATION.”

 

 

Improperly sealed, hot or cold supply

Turn off heater & water, repair unit.

WATER LEAKS

connections, relief valve, drain valve or

thermostat threads.

 

 

 

 

Leakage from other appliances or water lines

Inspect other appliances near water heater.

 

 

Condensation of flue products

Refer to “CONDENSATION.”

LEAKING T&P VALVE

Thermal expansion in closed water system

Install thermal expansion tank (DO NOT plug T&P valve).

Improperly seated valve

Checkreliefvalveforproperoperation(DONOTplugT&Pvalve).

 

 

HOT WATER ODORS

High sulfate or mineral content in water

Drain and flush heater thoroughly, chlorinate, refill

OR COLOR

supply or iron or sulfate reducing bacteria in

and flush again then chlorinate water supply.

(Refer to CATHODIC

water supply

 

 

PROTECTION)

 

 

 

 

17

Image 17
Contents Models BTI-80 GAS and Electrical Characteristics Model Dimensions ModelTOP View Model InputTable of Contents Installation Instructions Hard Water ClearancesAIR Requirements Unconfined SpaceVent Connection VentingRelief Valve Combination Water Potable Heating Space HeatingGAS Piping System ConnectionsWiring Diagram and Schematic Figure Heater WiringTo Operate the Heater PurgingGAS Pressure Regulator What to do if YOU Smell GAS For Your Safety Read Before OperatingD E F Temperature RegulationChecking Venting High Temperature Limit Switch ECO Service InformationMain Burner and Igniter Checking GAS InputPreventive Maintenance FLO-JUG Method of Deliming Tank Cleanout ProcedureCathodic PROTECTION-ANODE ChecklistCondensation Service and Repair TroubleshootingGAS and Electric Power are ON,OFF/ON Switch is on Water Heating CycleOr Color Yellow FlameWater Heater Control TroubleshootingClaim Procedure Service and Repair ExpensesTank ALL Other PartsReplacement Parts