A.O. Smith 185363-001 instruction manual GAS Piping with Flexibleconnector

Page 12

GAS PIPING

Make sure the gas supplied is the same type listed on the model rating plate. The inlet gas pressure must not exceed 14 inch water column (3.5 kPa) for natural and propane gas (L.P.). The minimum inlet gas pressure shown on the rating plate is that which will permit firing at rated input.

All gas piping must comply with local codes and ordinances or with the NationalFuelGasCode(ANSIZ223.1/NFPA-54)whicheverapplies.Copper andbrasstubingandfittings(excepttinlinedcoppertubing)shallnotbeused.

If the gas control valve is subjected to pressures exceeding 1/2 psi (3.5 kPa), the damage to the gas control valve could result in a fire or explosion from leaking gas.

If the main gas line Shut-off serving all gas appliances is used, also turn “off” the gas at each appliance. Leave all gas appliances shut “off” until the water heater installation is complete.

A gas line of sufficient size must be run to the water heater. Consult the current edition of National Fuel Gas Code ANSI Z223.1/NFPA54 and your gas supplier concerning pipe size.

There must be:

A readily accessible manual shut off valve in the gas supply line serving the water heater, and

A drip leg (sediment trap) ahead of the gas control valve to help prevent dirt and foreign materials from entering the gas control valve.

A flexible gas connector or a ground joint union between the shut off valve and control valve to permit servicing of the unit.

Be sure to check all the gas piping for leaks before lighting the water heater. Use a soapy water solution, not a match or open flame. Rinse off soapy solution and wipe dry.

When installed at elevations above 7,700 feet (2,347 meters), input rating should be reduced at the rate of 4 percent for each 1,000 feet (305 meters) above sea level which requires replacement of the burner orifice in accordance with National Fuel Gas CodeANSI Z223.1/ NFPA 54. Contact your local gas supplier for further information.

Failure to replace the standard orifice with a high altitude orifice when installed could result in improper and inefficient operation of the appliance, producing carbon monoxide gas in excess of safe limits, which could result in serious injury or death. Contact your gas supplier for any specific changes which may be required in your area.

Use pipe joint compound or teflon tape marked as being resistant to the action of petroleum [Propane (L.P.)] gases.

The appliance and its gas connection must be leak tested before placing the appliance in operation.

The appliance and its individual Shut-off valve shall be disconnected from the gas supply piping system during any pressure testing of that system at test pressures in excess of 1/2 pound per square inch (3.5 kPa). It shall be isolated from the gas supply piping system by closing its individual manual Shut-off valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1/2 pound per square inch (3.5 kPa).

Connecting the gas piping to the gas control valve of the water heater can be accomplished by either of the two methods shown in Figures 12 and 13.

FIGURE 12. GAS PIPING WITH

FLEXIBLECONNECTOR.

FIGURE 13. GAS PIPING WITH ALL

BLACK IRON PIPE TO GAS CONTROL.

12

Image 12
Contents Residential GAS Water Heaters Division OFA. O. Smith CorporationSafe INSTALLATION, USE and Service Important DefinitionsGeneral Safety Table of Contents IntroductionTypical Installation Natural HOT Surface Igniter & Main BurnerPropane HOT Surface Igniter & Main Burner Mixing Valve Usage HotterwatercanscaldLocating the NEW Water Heater Facts to Consider about the LocationInsulation Blankets ALL AIR from Inside Buildings See ALL AIR from Outdoors See Figures 7, 8Installing the NEW Water Heater Water PipingHotter Water can Scald TEMPERATURE-PRESSURE Relief Valve Valve and Pipe Insulation if suppliedGAS Piping with Flexibleconnector GAS PipingBlower Assembly Installation SequenceofinstallationSediment Traps Filling the Water HeaterVent Connections to Blower Assembly Venting and InstallationCondensate Maximum and Minimum Vent LengthsVent Terminal Installation VentingMasonry Side Walls Wooden Side WallsVertical Vent Through Roof Vertical Vent Termination RestrictionsVent Pipe Preparation Recommended BRUSH* Size for Primer Cement ApplicationsStepb StepeStepf StepgWatertemperatureadjustment PowerbeforeservicingDo not try to light the burner by hand What to do if YOU Smell GASTemperature Regulation Temperature Setting Burns on Adult SkinFor Your Information Start UP ConditionsOperational Conditions Periodic Maintenance Burner CleaningVenting System Inspection Burner Operation and InspectionTEMPERATURE-PRESSURE Relief Valve Operation Drain Valve Washer ReplacementAnode ROD Inspection DrainingService Leakage CheckpointsRepair Parts List Burner Assembly Drain PAN Outer Door AlternateNot Shown Optional Troubleshooting Guidelines Trouble ShootingTroubleshooting Guidelines Page Page Service and Labor Responsibility Claim ProcedureConditions and Exceptions Limitation on Implied WarrantiesTH STREET, ALSIP, IL Phone 1-800-433-2545 FAX

185363-001 specifications

A.O. Smith is renowned for producing high-quality water heating solutions, and the model 185363-001 stands as a testament to the company’s commitment to innovation and efficiency. This water heater is designed to provide reliable hot water for residential and commercial applications, ensuring that users enjoy consistent performance throughout its lifespan.

One of the standout features of the A.O. Smith 185363-001 is its impressive energy efficiency. The unit is built with advanced insulation that minimizes heat loss, thus allowing it to achieve a higher Energy Factor (EF) rating. This efficiency not only contributes to reduced energy bills but also aligns with modern environmental standards, making it a responsible choice for eco-conscious consumers.

The 185363-001 model utilizes a robust tank design that ensures durability and optimal performance. Made from high-grade materials, the tank is resistant to corrosion and wear, extending the heater's lifecycle. Additionally, the unit's glass-lined interior offers added protection against rust and mineral buildup, promoting effective heat transfer and consistent hot water supply.

In terms of capacity, the A.O. Smith 185363-001 is designed to meet the demands of various households. It comes in multiple sizes, catering to different needs, whether for a smaller apartment or a larger family home. This versatility makes it a popular option for installers and homeowners alike.

The water heater is also equipped with advanced safety features, including a temperature and pressure relief valve, which prevents potential hazards by protecting the tank from excessive heat or pressure. Furthermore, the control system includes an adjustable thermostat, allowing users to set their preferred water temperature efficiently.

Another important characteristic of the A.O. Smith 185363-001 is its user-friendly design. The unit is straightforward to operate, which simplifies maintenance and reduces downtime. For technicians, the heater features a modular design that facilitates servicing and replacement of components, ensuring quick repairs when needed.

Overall, the A.O. Smith 185363-001 embodies reliability, efficiency, and ease of use, making it a superb choice for anyone in need of a dependable water heating solution. Its combination of innovative technology and user-centric design ensures that it not only meets but exceeds the expectations of customers, solidifying A.O. Smith's reputation as a leader in the water heater market.