VENT CONNECTIONS TO BLOWER ASSEMBLY

Figure 15 shows the optimal placement of the 2" to 3" or 3" to 4" reducer; however, the vent can be reduced at any point in the vent system as long as the maximum and minimum vent length requirements are met.

FIGURE15.

VENTING AND INSTALLATION

Plan the layout of the vent system from the vent termination to the water heater considering all of the 90° and 45° elbows plus the number of feet of pipe that would be needed to install the total vent system. The water heater must be vented to the outdoors as described in these instructions. DO NOT connect this water heater to an existing vent or chimney. It must be vented separately from all other appliances. Nonmetallic vent may be used if it has “Heat Deflection Temperature” (HDT@66 psi) or 455 kPa of at least 157°F or 69°C. Typical nonmetallic vent materials meeting this requirement are: PVC (Schedule 40, ASTM D-1785), Coex Cellular Core (Schedule 40, ASTM F-441), CPVC (Schedule 40, ASTM D-2846), ABS (Schedule 40, ASTM D-2661). The fittings, other than the supplied Vent Termination should be equivalent to the following: PVC (Schedule 40, DWV, ASTM D-2665), CPVC (Schedule 40, DWV, ASTM F-438), ABS (Schedule 40 DWV, ASTM D-2661).

The cement used should be as recommended by the vent pipe manufacturer. See the instructions on pages 18 and 19 for the proper method of cutting and cementing the PVC pipe and fittings.

14

Image 14
Contents Residential GAS Water Heaters Division OFA. O. Smith CorporationSafe INSTALLATION, USE and Service Important DefinitionsGeneral Safety Table of Contents IntroductionPropane HOT Surface Igniter & Main Burner Typical InstallationNatural HOT Surface Igniter & Main Burner Mixing Valve Usage HotterwatercanscaldLocating the NEW Water Heater Facts to Consider about the LocationInsulation Blankets ALL AIR from Inside Buildings See ALL AIR from Outdoors See Figures 7, 8Hotter Water can Scald Installing the NEW Water HeaterWater Piping TEMPERATURE-PRESSURE Relief Valve Valve and Pipe Insulation if suppliedGAS Piping with Flexibleconnector GAS PipingSediment Traps Blower Assembly InstallationSequenceofinstallation Filling the Water HeaterVent Connections to Blower Assembly Venting and InstallationCondensate Maximum and Minimum Vent LengthsMasonry Side Walls Vent Terminal InstallationVenting Wooden Side WallsVertical Vent Through Roof Vertical Vent Termination RestrictionsVent Pipe Preparation Recommended BRUSH* Size for Primer Cement ApplicationsStepf StepbStepe StepgDo not try to light the burner by hand WatertemperatureadjustmentPowerbeforeservicing What to do if YOU Smell GASTemperature Regulation Temperature Setting Burns on Adult SkinOperational Conditions For Your InformationStart UP Conditions Venting System Inspection Periodic MaintenanceBurner Cleaning Burner Operation and InspectionAnode ROD Inspection TEMPERATURE-PRESSURE Relief Valve OperationDrain Valve Washer Replacement DrainingService Leakage CheckpointsNot Shown Optional Repair Parts ListBurner Assembly Drain PAN Outer Door Alternate Troubleshooting Guidelines Trouble ShootingTroubleshooting Guidelines Page Page Conditions and Exceptions Service and Labor ResponsibilityClaim Procedure Limitation on Implied WarrantiesTH STREET, ALSIP, IL Phone 1-800-433-2545 FAX

185363-001 specifications

A.O. Smith is renowned for producing high-quality water heating solutions, and the model 185363-001 stands as a testament to the company’s commitment to innovation and efficiency. This water heater is designed to provide reliable hot water for residential and commercial applications, ensuring that users enjoy consistent performance throughout its lifespan.

One of the standout features of the A.O. Smith 185363-001 is its impressive energy efficiency. The unit is built with advanced insulation that minimizes heat loss, thus allowing it to achieve a higher Energy Factor (EF) rating. This efficiency not only contributes to reduced energy bills but also aligns with modern environmental standards, making it a responsible choice for eco-conscious consumers.

The 185363-001 model utilizes a robust tank design that ensures durability and optimal performance. Made from high-grade materials, the tank is resistant to corrosion and wear, extending the heater's lifecycle. Additionally, the unit's glass-lined interior offers added protection against rust and mineral buildup, promoting effective heat transfer and consistent hot water supply.

In terms of capacity, the A.O. Smith 185363-001 is designed to meet the demands of various households. It comes in multiple sizes, catering to different needs, whether for a smaller apartment or a larger family home. This versatility makes it a popular option for installers and homeowners alike.

The water heater is also equipped with advanced safety features, including a temperature and pressure relief valve, which prevents potential hazards by protecting the tank from excessive heat or pressure. Furthermore, the control system includes an adjustable thermostat, allowing users to set their preferred water temperature efficiently.

Another important characteristic of the A.O. Smith 185363-001 is its user-friendly design. The unit is straightforward to operate, which simplifies maintenance and reduces downtime. For technicians, the heater features a modular design that facilitates servicing and replacement of components, ensuring quick repairs when needed.

Overall, the A.O. Smith 185363-001 embodies reliability, efficiency, and ease of use, making it a superb choice for anyone in need of a dependable water heating solution. Its combination of innovative technology and user-centric design ensures that it not only meets but exceeds the expectations of customers, solidifying A.O. Smith's reputation as a leader in the water heater market.