Chicago Electric 65712 manual See Figure M

Page 16

tions. The Trolley can remain disconnected until connecting the Straight Door Arm (46) to the Trolley is completed. (See Figure L.)

FIGURE M

HANGING BRACKET (28)

 

 

 

 

 

 

CONCRETE ANCHOR (30)

HANGING BRACKET (28)

 

 

 

 

 

 

 

CONCRETE ANCHOR (30)

TAPPING SCREW (29)

 

 

 

 

 

 

NUT (27)

TAPPING SCREW (29)

 

NUT (27)

 

 

 

HEX

30

 

 

27

 

 

 

 

 

BOLT

26

 

29

 

(26)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

15.Lift the garage door to its full open position, and rest the Garage Door Opener on the garage door. Insert one Hex Bolt (26), with its thread facing outward, into an Angle Bracket (24) located on each side of the Housing (31). (See Figure M.)

16.Bend the two Hanging Brackets (28) so they are flat against the ceiling. Lift the

Housing (31) until the Rail (35) is parallel to the ceiling. If necessary, use a carpen- ter’s level. Insert a hole in the Hanging Brackets onto the previously installed Hex Bolts (26) on each side of the Housing. Secure the bottom portion of the Hanging Brackets to the Housing using one Nut (27) for each Hex Bolt.

(See Figure M.)

17.For concrete ceilings, drill 5/16” diameter pilot holes into the ceiling and insert the Concrete Anchors (30). Secure the Hanging Brackets (28) to the ceiling with Hex Tapping Screws (29). For wood ceilings, drill 5/32” diameter pilot holes and secure with the Tapping Screws (29). (See Figure M.)

FIGURE N

DOOR

HEX

BRACKET

TAPPING

(50)

SCREW

 

(53)

DOOR

BRACKET

(50)

18.For sectional and one-piece door installation: The Door Bracket (50) has two mounting holes. Center the Door Bracket at the top inside surface of the garage door. Then secure the Door Bracket to the door using two Hex Tapping Screws (53). (See Figure N.)

SKU 65712

For technical questions, please call 1-800-444-3353.

Page 16

Image 16 Contents
For technical questions or replacement parts, please call Distributed exclusively by Harbor Freight ToolsContents Important Safety Information Save This ManualPower equipment is dangerous in the hands of untrained users Specific Safety Warnings Grounding Double Insulated Tools Tools With Two Prong PlugsCal Code. See Outlets for 2-Prong Plug See Outlets for 2-Prong PlugSee Table a 25’ 50’ 75’Specifications UnpackingAssembly Figure C See Figure D SKU For technical questions, please call Figure F Figure H See Figure HSee Figures I and J Provided. See Figures I and JFigure K See Figure KFigure M See Figure MSee Figure O, Illustration a Figure OFigure P Setting Remote Control Codes SecondSetting Opening Limit See Figures T and USetting Closing Limit Figure WSetting Opening Force 99-1Setting Closing Force Figure JJSetting Automatic Closing Time 99-0Figure WW To test the safety reverse system Maintenance Servicing Please Read Following CarefullyTroubleshooting Problem Possible Causes Possible SolutionsRecord Product’s Serial Number Here Assembly Diagram Limited 90 DAY Warranty