Harbor Freight Tools 95591 - .75 HP, 95593, 95592 INSPECTION, MAINTENANCE, and Cleaning

Page 10

6.Carefully set the Pump in place. Do not lower or raise the Pump by the Power

Cord or Discharge Pipe. (See Figure E.)

7.The Float Switch (2) automatically switches on and off at a water depth of approxi- mately 4 inches. The ON/OFF height can be manually changed by adjusting the Float Switch Lock. CAUTION: Do not run the Pump dry. Doing so will increase wear to the unit and possibly cause seal damage. (See Figure E.)

Note: This Pump has a built-in thermal protector for the Motor which automatically shuts it off to avoid overheating. After the Motor cools, it will cycle back on. Wait for the cycle to continue. Do not try to turn on the Pump manually after it has auto- matically shut off.

8.Connect additional Discharge Pipe as needed to direct the water discharge to the desired location. The discharge should be kept as short as possible with a minimum number of turns. IMPORTANT: Do not exceed the maximum lift of the Pump:

Model 95591 = 20 Feet. Model 95592 = 24 Feet. Model 95593 = 26 Feet.

9.Connect the Power Cord & Plug to its 115 volt, GFCI electrical outlet, while making sure to form a “drip loop” in the Power Cord. (See Drip Loop, page 5.)

10.When the water level exceeds approximately 4 inches the Pump will automatically turn on and run continuously until the water level falls below 4 inches at which time the Pump will automatically turn off.

11.WARNING! When shutting off power to the Pump, always shut off the electrical power to the GFCI outlet first. Then, disconnect the Pump’s Power Cord & Plug from the GFCI outlet.

INSPECTION, MAINTENANCE, AND CLEANING

WARNING! Always shut off the electrical power to the GFCI outlet first. Then, dis- connect the Pump’s Power Cord & Plug from the GFCI outlet prior to performing any inspection, maintenance, or cleaning procedures.

1.Before each use, inspect the general condition of the Pump. Check for cracked or broken parts, damaged electrical wiring, clogged Impeller Cover, Impeller, Dis- charge Pipes, and any other condition that may affect safe operation. If abnormal noise or vibration occurs, have the problem corrected before further use.

Do not use damaged equipment.

SKU 95591/95592/95593

For technical questions, please call 1-800-444-3353

PAGE 10

Image 10 Contents
For technical questions or replacement parts, please call Distributed exclusively by Harbor Freight ToolsSave this Manual SpecificationsGeneral Safety Rules ModelPersonal Safety Electrical SafetyWork Area Specific Safety Rules ServiceDo not pump hazardous materials Plug and Outlet Prong Plug and Outlet Outlet Outlets for 2-Prong PlugSee Table a 25’ 50’ 75’Unpacking Assembly and Operating InstructionsAny outlet should be well above the water line Figure E See Figure EINSPECTION, MAINTENANCE, and Cleaning Do not use damaged equipmentDiagram Problem Possible SolutionPlease Read the Following Carefully Parts ListPart Description Qty Diagram Limited 1 year / 90 Day warranty