SPECIFICATIONS
| Model 95591 | Model 95592 | Model 95593 |
Motor | 115 V~ / 60 Hz / 4 A | 115 V~ / 60 Hz / 5.5 A | 115 V~ / 60 Hz / 6 A |
| / 3/4 HP | / 1 HP | / 1.5 HP |
Power Switch Type |
| Automatic Float Switch |
|
Power Plug Type |
|
| |
Self Priming |
| Yes |
|
Maximum Pumping Capacity | 3,000 GPH | 3,300 GPH | 3,700 GPH |
Maximum Delivery Height | 20’ | 24’ | 26’ |
Discharge Diameter | |||
Max. Operating Temperature |
| 95° Fahrenheit |
|
Total Lift (feet)
30
25
20
15
10
5
0
Performance Chart
KEY
Model 95591
Model 95592
Model 95593
500 | 1000 | 1500 | 2000 | 2500 | 3000 | 3500 | 4000 |
GPH
Note: Performance of these products will vary depending on variations in local line volt- age.
SAVE THIS MANUAL
You will need this manual for the safety warnings and precautions, assem- bly, operating, inspection, maintenance and cleaning procedures, parts list and assembly diagram. Keep your invoice with this manual. Write the invoice number on the inside of the front cover. Keep this manual and invoice in a safe and dry place for future reference.
GENERAL SAFETY RULES
WARNING! Read all instructions Failure to follow all instructions listed on the following pages may result in electric shock, fire, and/or serious injury.
SAVE THESE INSTRUCTIONS
REV 08b; 09a
SKU 95591/95592/95593 | For technical questions, please call | PAGE 2 |