GENERAL PLUMBING
FOR SOLVENT WELD CONNECTIONS
Rigid or flexible PVC pipe can be used. Pipe ends should be clean and free of any flash caused by the cutting operation. Be sure that the proper adhesive is used on the type of pipe specified.
Recommended Adhesives- These are examples only and are not intended to restrict brands.
|
|
|
|
Suregard Flex 20 | Suregard |
|
|
IPS | IPS |
|
|
NOTE: A Primer will assure that adhesives joints are superior. Sureguard
CAUTION- We recommend that you consider climatic conditions when applying adhesives. Certain atmospheric situations, such as high moisture content, make the adhesive action of certain glues less effective. Check the manufacturer’s instructions.
FOR THREADED CONNECTIONS
Use only Teflon tape or equivalent on threaded plumbing connections. Other pipe compounds may damage threads. We do not recommend the
use of silicone or petroleum based compounds.
DO NOT OVER TIGHTEN! HAND TIGHTEN PLUS 1/2 TURN IS SUFFICIENT.
PUMP PLUMBING
All S & J Series pumps are union connected allowing quick and easy service without disturbing the plumbing. Two different plumbing configurations are available offering
To maximize the 100% drain feature, keep the piping as straight and short as possible, and slope horizontal runs so water drains away from pump. The suction line must be installed at an elevation below the water level when the tub is filled to guarantee flooded suction.
ELECTRICAL DATA
Refer to information on motor nameplate for electrical service data. All motors should have fused disconnect switch or circuit breaker. Be sure wire size is sufficient for HP and distance from power source. Wiring should be done in accordance with applicable codes by competent electrician. We recommend the installation of a ground fault circuit interrupter for maximum safety.
PUMP START UP
Fill tub to desired level making sure that suction fittings and jets are below water level. Start pump and open all suction and discharge line valves.
After about 10 minutes of operation, check the return fittings for air bubbles. A continuous flow of air indicates leaks in the suction line. Locate and correct any leaks immediately.
CAUTION- Do not operate pump with closed suction or discharge valves.
TWO-SPEED PUMPS
In spa and hot tubs, use high speed to atain full performance in the
In jetted tubs, use high speed to attain full performance in the
NOTE:
PUMP MAINTENANCE
1.Motors are
2.Clean Hair & Lint Strainer if you have a pump with strainer body.
3.Visually inspect motor for blockage of air vents on motor shell. Remove any debris after shutting off breaker.
4.Shaft seals may become worn and must be replaced if leakage is observed.
SERVICE AND REPAIR PARTS
Refer all service to your local dealer as his knowledge of your equipment makes him the best qualified source of information. Order all repair parts through your dealer. Give the following information when ordering repair parts.
1.Unit nameplate data
2.Description of part