Operation/Maintenance

Pressure Relief Procedure

WARNING

SKIN INJECTION HAZARD

The system pressure must be manually relieved to prevent the system from starting or spraying accidentally. Fluid

under high pressure can be injected through the skin and cause serious injury. To reduce the risk of an injury from injection, splashing fluid, or moving parts, follow the Pressure Relief Procedure whenever you:

Dare instructed to relieve the pressure,

Dstop spraying,

Dcheck or service any of the system equipment,

Dor install or clean the spray tips.

1.Lock the gun trigger safety.

Packing Nut/Wet-Cup

Before starting, fill the packing nut (U) 1/3 full with Graco Throat Seal Liquid (TSL) or compatible solvent. See Fig. 7.

WARNING

To reduce the risk of serious injury whenever you are instructed to relieve pressure, always follow the Pressure Relief Procedure at left.

The packing nut is torqued at the factory and is ready for operation. If it becomes loose and there is leaking from the throat packings, relieve pressure, then tighten the nut as specified in your separate pump manual. Do this whenever necessary. Do not overtighten the packing nut.

2.Shut off the air supply to the pump.

3.Close the bleed-type master air valve (required in your system).

4.Unlock the gun trigger safety.

5.Hold a metal part of the gun firmly to the side of a grounded metal pail, and trigger the gun to relieve pressure.

6.Lock the gun trigger safety.

7.Open the drain valve (required in your system), having a container ready to catch the drainage.

8.Leave the drain valve open until you are ready to spray again.

If you suspect that the spray tip or hose is completely clogged, or that pressure has not been fully relieved after following the steps above, very slowly loosen the tip guard retaining nut or hose end coupling and relieve pressure gradually, then loosen completely. Now clear the tip or hose.

Flush the Pump Before First Use

Pumps are tested with lightweight oil which is left in to protect the pump parts. To prevent contamination of the fluid, flush the pump with a compatible solvent before using it.

Model 254187 Shown

U

4414B

Fig. 7

14 307932

Image 14
Contents Part No , 331, Series B Important Safety InstructionsInstructions Part No , 281, Series aTable of Contents SymbolsSkin Injection Hazard Cal treatmentFire and Explosion Hazard Grounding InstallationGeneral Information Supplied Components System AccessoriesAir Line Accessories Red-handled bleed-type master air valveKEY Supplied Components 4414B 44b Converting to a Heated System Accessories for a Heated SystemInstalling Dual Heater Mounting Kit Viscon HP Heater Cord Install the warning label 51 as shown in Fig Installing Circulating Kit 34* 4 27* B Ref 40 49 Packing Nut/Wet-Cup Operation/MaintenancePressure Relief Procedure Flush the Pump Before First UseStarting and Adjusting the Pump Heated Circulating SystemsShutdown and Care of the Pump FlushingParts Model 245187, 331, Series B Model 253697, 281, Series aIncluded in Dual Heater Mounting Kit 222311. Required to 27* B Ref 30*39 41 39 40 49 Mounting Hole Layout Sound Pressure Levels Technical DataSound Power Levels Category DataToll Free Graco Standard WarrantyGraco Information