Ace Hardware R-30-T7 installation manual Important Select Correct Voltage

Page 3

FINDING THE DEPTH OF YOUR WELL

The jet tank system installs differently depending on the depth of your well. Tie a small but heavy weight to the end of a piece of string (be sure there is enough string; some wells are very deep). Lower the weight into the well until it reaches the bottom. Take up the slack and mark the string at ground level. Pull the weight out of the well and measure from the bottom of the weight to the ground level mark. This is the depth of your well. Subtract five feet from the depth of your well. This number should not exceed the maximum rated depth for your pump. If it does, it will greatly hinder or prevent the proper operation of the pump.

115V OR 230V OPERATION

Your pump is equipped with one of two types of dual voltage motors. Follow the instructions to wire the motor for the proper voltage. The voltage of the pump must match the voltage of the power supply.

IMPORTANT SELECT CORRECT VOLTAGE

VOLTAGE SELECTOR

 

GRD

AT REAR OF MOTOR

 

UNGROUNDED

(USE NEEDLE

 

LINE

NOSE PLIERS)

230V

 

PULL SELECTOR -

L1

 

ROTATE - REINSERT

115V

 

HIGH

LOW

L2

VOLTAGE

VOLTAGE

 

230

 

VOLTAGE

 

 

 

SELECTOR

TERMINAL BOARD

 

 

 

115USE COPPER CONDUCTORS ONLY

WIRE SELECTION GUIDE

 

NAME

MAX. WIRE LENGTH USING AWG SIZE

VOLTAGE

PLATE

 

 

 

 

#14

#12

#10

#8

 

AMPS

115

10.6

118

189

296

464

 

 

 

 

 

 

230

5.3

475

756

1184

1857

 

 

 

 

 

 

FUSE AND CIRCUIT

BREAKER SIZE GUIDE

STANDARD LINE

LOW PEAK - CART. TYPE

CIRCUIT BREAKER

FUSETRON - CART. TYPE

PLUG FUSE*

FUSTAT - PLUG TYPE*

 

 

 

 

 

 

 

 

 

 

 

 

115V

230V

115V

230V

115V

230V

 

 

 

 

 

 

20

10

12

6-1/4

20

15

 

 

 

 

 

 

*For circuits not over 150 volts to ground.

WIRING YOUR PUMP

Remove the cover from the pressure switch. Connect the bare copper ground to the ground screw in the pressure switch. Connect the power supply to the terminals marked "Line" in the diagram below.

LINE

MOTOR

MOTOR

LINE

GROUND

23833A343

3

Image 3
Contents 23833A343 JET Tank SystemImportant Instructions Before Installation Shallow Well Pump CapacitiesDeep Well Pump Capacities Important Select Correct Voltage Draining for Servicing or for Winter Shallow Well Pump Installation 4 Diameter Cased WellTools Needed for all pump installations PipingThan 24 lbs. for the R520. If no pressure shows Step Deep Well Pump Installation 4 Diameter Cased WellComplete Deep Well Installation Problem Possible Causes Limited WarrantyReplacement Parts JET Tank System13, 19 Retain these instructions for future reference Revision to Parts List