Chicago Electric 94649 operating instructions Troubleshooting, Maintenance

Page 6

Troubleshooting

SYMPTOM

CAUSE

SOLUTION

 

 

 

 

No power

Check power source; Reset GFCI

The pump will not start

Impeller blocked

Free impeller (see Maint.)

Thermal protection shutdown

Allow pump to cool down; auto restart

 

 

Entangled Float Switch

Check Float Switch

 

 

 

 

Pump submerged too deep

Reduce submersion depth

 

Discharge pipe bent

Free bends from pipe

The pump operates but

Suction grid clogged

Clean suction grid

pumps little or no water

Air locked in suction base

Turn off pump for 10 seconds

 

Optional check valve stuck or

Examine check valve

 

installed backwards

 

 

 

 

Excessive noise or

Worn bearings

Have a qualified technician repair

vibration

Debris in impeller

Clean out impeller inlet

 

 

 

 

Water temperature too high

Never use pump in water over 95

Pump starts and stops

Defective or entangled Float

degrees F.

too frequently

Switch

Replace or reposition switch

 

Water backflow

Install a check valve at the outlet

 

 

 

Maintenance

Warning: Disconnect power before performing any maintenance.

1.Periodically clean the suction section of the pump, removing any foreign particles. Run in clean water to flush out system.

2.To remove particles stuck on the impeller, remove the screws (19) on the Base Cover (17), and pull Base (18) off.

3.Any other maintenance must be done by a qualified technician.