Specifications

Motor

120 V, 60 Hz, 7 Amp

Pump Cord

18 Ft. - 3 Prong Plug

Discharge Size

1-1/2”

Discharge Fittings

1-1/2”, 1-1/4” and 1”

Delivery Height

26.6 Ft.

Flow Rate

3300 GPH

Horsepower

3/4 HP

Max. Particle Size

1”

Min. Water Level

4”

Operating Temp.

95° F

Min. Switch Level

3”

Dimensions

6” Dia. x 13-1/2” H

Housing Material

PP Plastic

Pump Weight

10.4 lb.

Motor Drive

Magnetic Drive

Warning: The pump should not be submerged in water deeper than the length of the power cord, which is 18 feet long.

Save This Manual

You will need the manual for the safety warnings and precautions, assembly instructions, operating and maintenance procedures, parts list and diagram. Keep your invoice with this manual. Write the invoice number on the inside of the front cover. Keep the manual and invoice in a safe and dry place for future reference.

Safety Warnings and Precautions

WARNING: When using tool, basic safety precautions should always be followed to reduce the risk of personal injury and damage to equipment.

Read all instructions before using this tool!

1.Avoid pump damage. Do not operate dry. Never lift or transport the pump by the power cable or float switch cable.

2.Do not pump certain liquids. Do not pump gasoline, hydrocarbons, fuel oil, kerosene, fats, salt or waste water, or chemical agents. Do not pump hot liquids.

3.Avoid fire or explosion. Do not pump in close proximity to flammable or explosive materials.

4.Avoid working alone. If an accident happens, an assistant can bring help.

5.Avoid electrical shock. If the submersible pump is to be installed in a location where a breakdown or fault could cause injury to persons, or damage to objects, the power source must utilize a Ground Fault Circuit Interrupter (GFCI). This device will immediately shut down power in case of a short circuit. This device must be tested periodically. No persons should be in contact with the water being pumped.

6.Keep children away. Children must never be allowed in the work area. Do not let them handle machines, tools, or extension cords.

7.Store idle equipment. When not in use, tools must be stored in a dry location to inhibit rust. Always lock up tools and keep out of reach of children.

REV 07/06