2.3.11 HP ProtectTools Embedded Security

System Overview

2.3.11 HP ProtectTools Embedded Security

HP ProtectTools Embedded Security is a hardware/software solution providing file and folder encrypytion service that integrates with the operating system. The software component—the HP ProtectTools Embedded Security Manager (preinstalled), controls the basic operation of the hardware component—the Trusted Platform Module (TPM) security chip. These components are compliant with the Trusted Computing Group (TCG) security standards organization.

HP ProtectTools Embedded Security includes the following features:

Enhanced Windows operating system files and folder encryption

Enhanced email encryption—built-in authentication for Outlook, Outlook Express, Lotus Notes, Eudora

Strengthends defense against hacking, system attacks, denial of service and network attacks

“Embedded smart card” functionality

Strengthens authentication with LANs, WANs.

Works with/enhances third-party security solutions

HP ProtectTools Embedded Security Manager is acecssed through a Windows Control Panel applet. The management functions are accessible thro;ugh establishlished protocols such as DMI, SNMP, or WEBEM.

2.4 Specifications

This section includes the environmental, electrical, and physical specifications for the systems covered in this guide. Where provided, metric statistics are given in parenthesis. Specifications are subject to change without notice.

Table 2-6

Environmental Specifications (Factory Configuration)

Parameter

Operating

Non-operating

 

 

Ambient Air Temperature 50o to 95o F (10o to 35o C, max.

-22oto 140o F (-30oto 60o C, max.

 

rate of change < 10°C/Hr)

rate of change < 20°C/Hr)

 

 

 

 

Shock (w/o damage)

 

5 Gs [1]

20 Gs [1]

 

 

 

 

Vibration

0.000215

G2/Hz, 10-300 Hz

0.0005 G2/Hz, 10-500 Hz

 

 

 

 

Humidity

10-90%

Rh @ 28o C max.

5-95% Rh @ 38.7o C max.

 

wet bulb temperature

wet bulb temperature

 

 

 

Maximum Altitude

10,000 ft (3048 m) [2]

30,000 ft (9144 m) [2]

NOTE:

[1]Peak input acceleration during an 11 ms half-sine shock pulse.

[2]Maximum rate of change: 1500 ft/min.

 