HP 8000 tower manual A.9 Diskette Drive Error Messages

Models: 8000 tower

1 114
Download 114 pages 60.42 Kb
Page 101
Image 101
A.9 Diskette Drive Error Messages (6xx-xx)

Error Messages and Codes

A.9 Diskette Drive Error Messages (6xx-xx)

Table A-8.

Diskette Drive Error Messages

Message

Probable Cause

Message

Probable Cause

 

 

 

 

6xx-01

Exceeded maximum soft error limit

6xx-20

Failed to get drive type

 

 

 

 

6xx-02

Exceeded maximum hard error

6xx-21

Failed to get change line status

 

limit

 

 

 

 

 

 

6xx-03

Previously exceeded max soft limit

6xx-22

Failed to clear change line status

 

 

 

 

6xx-04

Previously exceeded max hard limit

6xx-23

Failed to set drive type in ID media

 

 

 

 

6xx-05

Failed to reset controller

6xx-24

Failed to read diskette media

 

 

 

 

6xx-06

Fatal error while reading

6xx-25

Failed to verify diskette media

 

 

 

 

6xx-07

Fatal error while writing

6xx-26

Failed to read media in speed test

 

 

 

 

6xx-08

Failed compare of R/W buffers

6xx-27

Failed speed limits

 

 

 

 

6xx-09

Failed to format a tract

6xx-28

Failed write-protect test

 

 

 

 

6xx-10

Failed sector wrap test

--

--

 

 

 

 

600-xx = Diskette drive ID test

609-xx = Diskette drive reset controller test

601-xx = Diskette drive format

610-xx = Diskette drive change line test

602-xx = Diskette read test

611-xx = Pri. diskette drive port addr. conflict

603-xx = Diskette drive R/W compare test

612-xx = Sec. diskette drive port addr. conflict

604-xx = Diskette drive random seek test

694-00 = Pin 34 not cut on 360-KB drive

605-xx = Diskette drive ID media

697-00 = Diskette type error

606-xx = Diskette drive speed test

698-00 = Drive speed not within limits

607-xx = Diskette drive wrap test

699-00 = Drive/media ID error (run Setup)

608-xx = Diskette drive write-protect test

 

 

Technical Reference Guide

www.hp.com

A-9

Page 101
Image 101
HP 8000 tower manual A.9 Diskette Drive Error Messages