4-SPECIFICATIONS

4-SPECIFICATIONS

4.1Power Requirements

Electrical: 120 Volt, 60Hz

Pneumatic: 5 bar gauge pressure [70PSIG]

110 liter/min @ 21°C, 1.01 bar [3.75 SCFM] at 15 boxes per minute A pressure regulator is included

4.2Operating Rate

Box drive belt speed is approximately 0.5 m/s [100 feet per minute].

4.3Operating Conditions

Use in dry, relatively clean environments at 5o C to 50o C [40o F to 120o F] with clean, dry boxes. Note: Machine should not be washed or subjected to conditions causing moisture condensation on

components.

WARNING

• To reduce the risk associated with fire and explosion hazards:

− Do not operate this equipment in poten-

tially flammable or explosive environments.

4.4Tape

Scotch® pressure-sensitive film box sealing tapes.

4.5Tape Width

36mm [1 1/2 inch] minimum to 48mm [2 inch] maximum

700r-NA

14