3M 40800 operating instructions Installation

Models: 40800

1 144
Download 144 pages 27.28 Kb
Page 29
Image 29
7-INSTALLATION

7-INSTALLATION

7.1 Operating Conditions

The machine should operate in a dry and relatively clean environment (See Specif cations).

7.2Space Requirements for Machine Operation and Maintenance Work

Minimum distance from wall (Figure 7-1):

A= 1000mm.

B= 700mm.

Minimum height = 2700mm.

B

A

Figure 7-1

WARNING

To reduce the risk associated with muscle strain:

Use the appropriate rigging and material handling equipment when lifting or repositioning this equipment.

Use proper body mechanics when removing or installing taping heads that are moderately heavy or may be considered awkward to lift.

7.4Machine Positioning / Bed Height

1 - Lift the machine with belts or ropes paying attention to place the belts in the points (Figure 7-2).To set the machine bed height, do the following:

Adjust machine bed height. The case sealer is equipped with four (4) adjustable legs that are located at the corners of the machine frame.

The legs can be adjusted to obtain different machine bed heights - See Specif cations.

Note – Minimum machine bed height can be reduced to 570mm [22.5 inch] by moving outer columns up one set of mounting holes. However, this change also increases minimum box height of 120 mm

7.3 Tool Kit Supplied with the Machine

A tool kit containing some tools are supplied with the machine. These tools should be adequate to setup the machine, however, other tools supplied by the customer will be required for machine maintenance.

Figure 7-2

700r-NA

[4.8 inch] to 170mm [6.8 inch].

Refer to Figure 7-3and set the machine bed height as follows:

2.Loosen, but do not remove, two (2) M8 x 1.25 socket head screws in one leg (use M6 hex wrench). Adjust the leg length for the desired machine bed height. Retighten the two (2) screws to secure the leg. Adjust all four (4) legs equally.

M8 x 1.25mm

Socket Head

Screws

Adjustable

Legs

Figure 7-3

19

2011 July

Page 29
Image 29
3M 40800 operating instructions Installation