Chicago Electric 95591-.75 HP operating instructions Diagram, Problem Possible Solution

Page 11

2.To clean the Impeller Cover and Impeller: A clogged or dirty Impeller Cover or Impeller (28) will greatly reduce performance of the Pump. To clean the Impel- ler Cover (31), spray the Cover with clean water. To clean the Impeller, remove the nine Screws (32) at the bottom of the Base (25). Then, remove the Base to expose the Impeller Cover and Impeller. Use a stream of clean water to clean the Impeller and Impeller area inside the Pump. Then, replace the Base. (See Assy.

Diagram.)

3.When finished, store the Pump in a clean, dry and safe location out of reach of children. In cold weather, when the Pump is not in use, protect the interior of the Pump from freezing by draining the water and pumping a permanent type automo- bile anti-freeze containing a rust inhibitor through the system. A 50% mixture with water is recommended. Be sure to flush the system with a neutralizing liquid prior to re-use of the Pump. Note: Always properly dispose of all used anti-freeze.

CAUTION! All maintenance, service, or repairs not mentioned in this manual must only be performed by a qualified service technician.

 

 

 

 

 

 

TROUBLESHOOTING

 

 

 

Problem

 

Possible Solution

Pump does not start.

1. Make sure the Pump is plugged into a working, 115 volt, GFCI

 

electrical outlet.

2.Adjust the Float Switch to a lower position.

No flow from the Pump. 1. Clean Impeller and Impeller Cover.

 

2.

Check Discharge Pipe for freezing or blockage. If necessary, thaw

 

 

Pipe and/or remove excess debris.

 

3.

Discharge Pipe excessively bent. Straighten Pipe.

Pump does not automatically

1. Float Switch cannot sink down. Lower Float Switch.

switch off.

2.

Check for excessive debris beneath Float Switch.

 

3.

Unplug Pump from its electrical outlet. Discontinue using Pump until

 

 

a qualified service technician checks Pump for damage.

Insufficient flow.

1. Clean Impeller and Impeller Cover.

 

2.

Check Discharge Pipe for freezing or blockage. If necessary, thaw

 

 

Pipe and/or remove excess debris. Be careful of excessive lift height.

 

3.

Have a qualified service technician clean interior of Pump and, if

 

 

necessary, replace worn parts.

Pump switches off too soon.

1.

Clean Impeller and Impeller Cover.

 

2.

Make sure the water temperature does not exceed 95° Fahrenheit.

SKU 95591/95592/95593

For technical questions, please call 1-800-444-3353

PAGE 11

Image 11
Contents Distributed exclusively by Harbor Freight Tools For technical questions or replacement parts, please callWork Area SpecificationsGeneral Safety Rules Save this ManualTool USE and Care Electrical SafetyPersonal Safety Service Specific Safety RulesOutlet. See Drip Loop, right Drip LoopOutlets for 2-Prong Plug Prong Plug and OutletOutlet Plug and Outlet25’ 50’ 75’ See Table aAny outlet should be well above the water line Assembly and Operating InstructionsUnpacking See Figure E Figure EDo not use damaged equipment INSPECTION, MAINTENANCE, and CleaningProblem Possible Solution DiagramPart Description Qty Parts ListPlease Read the Following Carefully Diagram Limited 90 DAY Warranty