Chicago Electric 95591-.75 HP operating instructions Outlet. See Drip Loop, right

Page 5

This Pump is designed to move clean or dirty water only. Do not pump water hotter than 95 degrees Fahrenheit.

7.Make sure the discharge pipe (not included) is secured to a solid surface to ensure the stability of the Pump.

8.Make sure to position the Pump on a flat, level, solid surface.

9.Arrange a “drip loop” in the Power Cord connecting the Pump to a 115 volt,

GFCI electrical outlet. A drip loop is that part of the Power

 

 

 

 

Drip Loop

Cord below the level of the outlet to prevent water from

 

 

 

 

traveling along the Power Cord and coming in contact with

 

 

OUTLET

 

 

the outlet. If the Power Plug or electrical outlet does get

 

 

 

wet, do not unplug the Power Cord. Disconnect the fuse or

 

 

 

circuit breaker that supplies power to the Pump. Then,

DEVICE

unplug the Power Cord and examine for presence of water

 

 

 

in the outlet. (See Drip Loop, right.)

 

 

CORD

10.If necessary, have a certified electrician install (within 10 feet of where the

Pump will be located) a 115 volt, GFCI electrical outlet that is dedicated only to the Pump. Any outlet should be above the water line.

11.NEVER raise or lower the Pump by its electrical Power Cord.

12.In cold weather, when the Pump is not in use, protect the interior of the Pump from freezing by draining the water and pumping a permanent type automo- bile anti-freeze containing a rust inhibitor through the system. A 50% mixture with water is recommended. Be sure to flush the system with a neutralizing liquid prior to re-use of the Pump.

13.If an extension cord is used (for temporary use only) connections must not come in contact with water or any wet surfaces.

14.Prior to use, and periodically thereafter, check to make sure all connections are tight and secure.

15.Industrial applications must follow OSHA requirements.

16.Performance of this product may vary depending on variations in local line voltage.

17.People with pacemakers should consult their physician(s) before use. Elec- tromagnetic fields in close proximity to heart pacemaker could cause pace- maker interference or pacemaker failure.

18.The warnings and cautions discussed in this manual cannot cover all pos- sible conditions and situations that may occur. It must be understood by the operator that common sense and caution are factors which cannot be built into this product, but must be supplied by the operator.

SKU 95591/95592/95593

For technical questions, please call 1-800-444-3353

PAGE 5

Image 5
Contents Distributed exclusively by Harbor Freight Tools For technical questions or replacement parts, please callGeneral Safety Rules SpecificationsSave this Manual Work AreaTool USE and Care Electrical SafetyPersonal Safety Service Specific Safety RulesOutlet. See Drip Loop, right Drip LoopOutlet Prong Plug and OutletPlug and Outlet Outlets for 2-Prong Plug25’ 50’ 75’ See Table aAny outlet should be well above the water line Assembly and Operating InstructionsUnpacking See Figure E Figure EDo not use damaged equipment INSPECTION, MAINTENANCE, and CleaningProblem Possible Solution DiagramPart Description Qty Parts ListPlease Read the Following Carefully Diagram Limited 90 DAY Warranty