FIGURE E
CHECK VALVE
OR
UNION
(NOT INCLUDED)
TO 115 VOLT, GROUNDED
GFCI OUTLET
DISCHARGE PIPE
(NOT INCLUDED)
o |
| 1/8” |
| AIR BLEED HOLE | |
|
BASE
(25)
3.Connect the Discharge Pipe to the Base (25). NOTE: Make sure the Discharge Pipe is secured to a solid surface, with appropriate hardware (not included), to ensure the stability of the Pump. (See Figure E.)
4.Install an additional union (not included) or other means of separating the Dis- charge Pipe just above the floor to facilitate removal of the Pump if necessary.
(See Figure E.)
5.A check valve (not included) is recommended just above, or in place of, the union to prevent the backflow of water after each pump cycle. If a Check Valve is used, a 1/8” diameter air bleed hole should be drilled through the Discharge Pipe just above the lower Base (25) to prevent Pump “airlock”. A small spray of water out of this hole is normal while the Pump is running. (See Figure E.)