Chicago Electric 95591-.75 HP operating instructions See Figure E

Page 9

FIGURE E

CHECK VALVE

OR

UNION

(NOT INCLUDED)

TO 115 VOLT, GROUNDED

GFCI OUTLET

DISCHARGE PIPE

(NOT INCLUDED)

o

 

1/8”

 

AIR BLEED HOLE

 

BASE

(25)

3.Connect the Discharge Pipe to the Base (25). NOTE: Make sure the Discharge Pipe is secured to a solid surface, with appropriate hardware (not included), to ensure the stability of the Pump. (See Figure E.)

4.Install an additional union (not included) or other means of separating the Dis- charge Pipe just above the floor to facilitate removal of the Pump if necessary.

(See Figure E.)

5.A check valve (not included) is recommended just above, or in place of, the union to prevent the backflow of water after each pump cycle. If a Check Valve is used, a 1/8” diameter air bleed hole should be drilled through the Discharge Pipe just above the lower Base (25) to prevent Pump “airlock”. A small spray of water out of this hole is normal while the Pump is running. (See Figure E.)

SKU 95591/95592/95593

For technical questions, please call 1-800-444-3353

PAGE 9

Image 9
Contents Distributed exclusively by Harbor Freight Tools For technical questions or replacement parts, please callGeneral Safety Rules SpecificationsSave this Manual Work AreaElectrical Safety Personal SafetyTool USE and Care Service Specific Safety RulesOutlet. See Drip Loop, right Drip LoopOutlet Prong Plug and OutletPlug and Outlet Outlets for 2-Prong Plug25’ 50’ 75’ See Table aAssembly and Operating Instructions UnpackingAny outlet should be well above the water line See Figure E Figure EDo not use damaged equipment INSPECTION, MAINTENANCE, and CleaningProblem Possible Solution DiagramParts List Please Read the Following CarefullyPart Description Qty Diagram Limited 90 DAY Warranty