Century CEXT7 manual Periodic Maintenance

Page 19

PERIODIC MAINTENANCE

Twice a month, flush a white vinegar solution (One quart vinegar to two gallons of water) or anti- browning solution (mixed as directed) through the extractor. This will prevent build-up of alkaline residue in the system. If spray jets become clogged, remove the spray tips, wash them thoroughly, and blow-dry.

NOTE: Do not use pins, wire, etc. to clean nozzles as this could destroy spray pattern.

Periodically inspect all hoses, electrical cables and connections on your machine. Frayed or cracked hoses should be repaired or replaced to eliminate vacuum or solution pressure loss. If the cable insulation is broken or frayed, repair or replace it immediately. Don’t take chances with electrical fire or shock.

DAILY / REGULAR MAINTENANCE

Before making any adjustments or repairs to the machine, disconnect the power cord from electrical source.

1.Empty unused cleaning solution from the solution tank.

2.Inspect and clean filter screen in solution tank.

3.Flush pumping system with 4 or 7 liters of clean, hot water.

4.After each use, rinse tank with fresh water. Periodically inspect the recovery tank and decontaminate if necessary, using a Hospital Grade Virucide or a 1-10 bleach to water solution. Waste water should be disposed of properly.

5.Check for and remove any lint or debris around vac shoe.

6.Check spray jets for full spray pattern.

MAINTENANCE

7.Remove lint and dirt build-up from brush and housing.

NOTE: Brush removal.

A.To remove brush, grab and pull brush out from end opposite drive belt (operator’s right). Remove other end from brush driver.

B.To install brush, line up slots in brush core with pin in driver on drive belt side (operator’s left) and push brush onto driver. Then snap bearing end (opposite end) of brush into retaining clip.

8.Check cooling air screen (located on frame behind left wheel) for lint or debris.

9.Check float and shut-off screen and clean as necessary.

NOTE: Always store machine with brush in “Store” position.

86037910 CEXT7 03/23/07

4-2

Image 19
Contents Carpet Extractor Your Dealer Machine Data LOG/OVERVIEWTable of Contents Model HOW to USE this ManualRead ALL Instructions Before Using this Machine Safety InstructionsHazard Intensity Level Hazard Intensity LevelThis Product is for Commercial USE only Grounding InstructionsPower Type Technical SpecificationsGeneral DIMENSIONS/WEIGHT Electrical Cord CONTROLS/COMPONENT LocationsCONTROLS/COMPONENT Locations CONTROLS/COMPONENT Locations Step Filling OperationsCorrect OperationsIntermittent Continuous Solution Intake Cover Vacuum Step Cleaning ProcedureOFF Step Recovery Drain Solution Accessory Tool Usage Maintenance Daily Weekly Quarterly Maintenance Service SchedulePeriodic Maintenance MaintenanceVacuum Motor Carbon Brushes Replacement Maintenance Pump Replacement Kits Shurflo 86026410 PRV no Solution Pump ReplacementWiring Diagram Problem Cause Solution Troubleshooting ChartCEXT7 03/23/07 Frame Assembly HARNESS, MAIN, CDT PRV no QTY Description Serial no FromFRAME, CLP Family HUBCAP, 5/8 ShaftBrush Assembly PLATE, Brush Housing LH HOUSING, BrushLEVER, Height Adjustment PLATE, Brush Housing RHSee Solution 5 Tank Pump AssemblyELBOW, SWIVEL,1/4MPTX3/8TUBEQC CONNECTOR, 1/8FPT X 1/4 TubeqcCOUPLING, 1/4 Anchor W/1 HEX ELBOW, SWIVEL, 1/4MPTX1/4TUBEFrom Serial no NIPPLE, 1/4 Bspt X 1/4 NPT HEX ELBOW, SWIVEL, 3/8MPTX3/8TUBEQCPump ASM, 120V Shurflo Valve ASM, 120V CLP FamilyVacuum Shoe Assembly ARM, VAC Shoe Parallel COVER, Accessory PortGASKET, Accessory Port PRV no QTY DescriptionSee Solution Tank Control Panel AssemblyLABEL, Ground Symbol BOOT, 3/8 Circuit BreakerSWITCH, Dpdt 3-POSITION Rocker SWITCH, Spst 2-POSITION RockerSolution Tank Assembly Tank ASM, Solution Items HOUSING, VAC MotorBrush SET, 120V VAC Service Only TANK, CDT SolutionRecovery Tank Assembly Dome TANK, RecoveryCORD, Drain Hose COVER, REC. TankSuggested Spare Parts Limited Warranty