Bissell 28F4, 80E7 warranty Clearing clog

Page 12

Maintenance and care

Clearing clog

Low suction, poor pickup or no suction may be due to a clog in the vacuum cleaner. If you notice a change in

the sound of the vacuum motor or a reduction in the spinning action in the dirt container, check for clogs.

1.Unplug cleaner from electrical outlet.

2.Empty dirt container.

3.Check upper tank and primary separa- tor for build up or clogs. Check to make sure primary separator is installed cor- rectly. To unlock the primary separator, grasp the rim and turn toward the left. Pull straight down to remove. If the pri- mary separator is missing or not locked into place, check and clear the tube in the center of the dirt container and prop- erly install primary separator.

4.Remove the Twist ‘n Snap hose from the vacuum by turning to the left. Check the suction inlet, hose and hose wand for clogs. Remove any clogs from the hose using a long, narrow object such as a broomstick.

5.Check the foot hose for clogs. If need- ed, remove the screw attaching the hose wand base to the vacuum. Straighten the foot hose and unclog with a long, narrow object such as a broomstick.

6.If the clog persists, follow the instructions for checking the rotating floor brush on page 11 and inspect the air passageway for obstructions.

Primary Separator

Suction Inlet

Hose Wand Base

Air Passageway

12w w w . b i s s e l l . c o m

Image 12
Contents CLEANview 80E7 and 28F4 SeriesThanks for buying a Bissell Cleanview Cyclonic Important Safety Instructions Reduce the risk of fire, electric shock, or injuryProduct view Assembly Attach handle to vacuumAttach vacuum hose and tools Powerfoot height adjustment Transporting cleanerLowest Setting For bare floors OperationsPower cord Turn power switch OFFSpecial tools Raise handle to upright positionMaintenance and care Emptying dirt containerFull Line UnlockCleaning the inner & outer circular filters Cleaning the pre-motor filterUnplug cleaner from electrical outlet Pre-Motor FilterReplacing the Hepa media post-motor filter Maintaining the TurboBrush toolMedia Post-Motor Filter Unplug cleaner from electrical outlet Brush Check rotating floor brush and drive beltReplace drive belt Clearing clog Troubleshooting Replacement parts Part Name203-1068 Extension Wand 203-1216 Warranty Limited One Year WarrantyFor spare parts and accessories For UK inquiriesIf your Bissell product should require service Bissell consumer services