3.Mount Filter Head Under Sink

A.Identify Filter Head and the two Elbow Fittings, and note that the Outlet Fitting has a black band. This fitting includes a small restrictor insert to insure maximum flow at 1/2 gallon per minute.

B.Apply Teflon Tape to the threads of each Elbow Fitting. Wrap tape in direction of the threads to assure a tight fit and avoid small leaks.

C.Screw Inlet Elbow Fitting into the left side of the filter head, and hand tighten only.

D.Screw Outlet Elbow Fitting (black band) into the right side of the filter head in the same manner.

E.Securely mount the filter head on the cabinet wall using the enclosed mounting screws and washers.

1.ATTACH INLET WATER SUPPLY

F.Locate and close the cold water Angle Stop Valve under your kitchen sink. Open cold water line of faucet to release water pressure.

G.Unscrew and disconnect the braided tubing on top of the Angle Stop Valve .

H.Attach the bottom of Angle Stop Adaptor to the existing cold water Angle Stop Valve.

I.Attach the braided tubing to the top of the Angle Stop Adaptor.

J.Close side valve on Angle Stop Adaptor and open cold water Angle Stop Valve to return water service to kitchen sink. Check for leaks.

NOTE: Teflon® Tape should not be required for these next steps.

K.Measure length of tubing needed to connect Angle Stop Adaptor to Inlet Elbow Fitting on Filter Head. Allow adequate tubing to avoid sharp turns.

L.Cut tubing at a 90° angle using a sharp knife.

M.Insert ends of tubing into quick-connect fittings. Push tube into fitting and gently pull to confirm a tight fit.

5.ATTACH FILTERED WATER TO SINK FAUCET

N.Install separate faucet for filtered drinking water. Follow individual manufacturer’s instructions.

O.Attach Faucet Connector Fitting to bottom end of threads on new faucet assembly. Teflon® Tape should not be required for this step.

P.Measure length of tubing needed to connect the Outlet Elbow Fitting on Filter Head to the new Faucet Connector Fitting. Allow adequate tubing to avoid sharp turns. Cut and insert each end of the tubing into the fittings.

OPTIONAL FILTER MONITOR (H300+M Filter System)

A Filter Replacement Monitor (EV3112-01) is included with the H300+M Filter System. It is a small water meter that counts the number of gallons used. This Monitor includes quick-connect fittings, and should be installed on the tubing between the filter system and the faucet connector.

Monitor Instructions (Document EV3112-52) are included with the H 300+M System.

3

 

C

D

B

 

 

 

E

4

F

G

I

H

 

L M

5

N

O

• •

Image 4
Contents Especificaciones Del Producto Product Specifications Caractéristiques Techniques Du Produit Page Tools Needed For Installation Open Carton & Inspect Parts Installation PartsModel H-54 Model H-300Mount Filter Head Under Sink Optional Filter Monitor H300+M Filter SystemInstructions Claims & Notes Modelo H-54 Instrucciones básicas de instalaciónModelo H-104 Conecte el abastecimiento de agua de entrada Monitor DE Filtro Opcional Sistema de filtro H300+MInstrucciones de instalación Ouvrez le carton et inspectez les pièces Pièces à installerInstale el cartucho filtrante y deje correr el agua Declaraciones y notas Cabezal de filtro dobleInstructions d’installation de base Modèle H-300Modèle H-300+M Modèle H-300-HSDMontage de la tête de filtre sous l’évier Raccordement de l’arrivée d’eauInstallation et rinçage de la cartouche filtrante Consignes d’utilisation pour l’HFrançais Revendication & remarquesPage Proof of Purchase Required