GE FNSF31Z01 Problem, Possible Causes, What To Do, No soft water, water. NOTE Be sure sample

Page 14
Problem

Safety Instructions

Before you call for service…

Problem

 

Possible Causes

What To Do

 

 

 

 

No soft water

 

Faucet or fixture where sample

To conserve salt, the installer may have isolated some

 

 

was taken not plumbed to soft

fixtures (outside faucets, toilets, etc.) from soft water.

 

 

water. NOTE: Be sure sample

From the outlet of the water softening system, trace the

 

 

is from a faucet that does not mix

water flow path, in house plumbing. If soft water is not

 

 

soft and hard water. For example,

directed to a faucet or fixture where wanted, consult a

 

 

a single lever kitchen faucet, if

plumber.

 

 

the cold side is plumbed to hard

 

 

 

water

 

 

 

 

 

 

 

No salt in the brine tank

Check for a salt bridge or, if the tank is empty, refill with

 

 

or salt bridged

recommended salt. Press (for 3 seconds) the TOUCH or

 

 

 

HOLD button to start an immediate regeneration and

 

 

 

restore soft water supply.

 

 

 

 

Operating Instructions

Transformer unplugged at wall outlet or power cable to water softening system not connected

Fuse blown or circuit breaker popped on circuit to electrical outlet

Electrical outlet on a circuit that can be switched off

Check for a loss of electrical power to the water softening system due to any of these conditions and correct as needed. With the power supply restored, observe the control display and read Program Memory section.

NOTE: The electrical outlet for the water softening system should be continuously live so it cannot be accidentally switched off.

Troubleshooting Tips

Customer Service

 

Manual bypass valve in

Be sure the bypass valve stem is positioned properly.

 

bypass position

Observe instruction on the decal at the end of the stem.

 

 

 

 

Valve drain hose pinched,

Any restriction in this drain hose may prevent proper

 

plugged, elevated too high

operation of the nozzle and venturi and reduce or

 

or otherwise restricted

prevent brine draw during regenerations.

 

 

 

 

Nozzle and venturi dirty,

With water pressure to the water softening system off, take

 

incorrectly assembled or

the nozzle assembly apart. Inspect, clean and replace as

 

damaged

needed. Any foreign particle(s), scratches, nicks, etc., in

 

 

the passages can prevent operation. Be sure holes in the

 

 

gasket are centered over holes in the housing.

 

 

 

Water hard sometimes

Using hot water while the

Avoid using hot water during water softening system

 

water softening system

regenerations because the water heater will refill with

 

is regenerating

hard water. See Automatic Hard Water Bypass During

 

 

Regeneration section.

 

 

 

 

Control hardness number

Press and release the SELECT button until HARDNESS shows

 

setting too low

in the display. Be sure the number shown is the same as the

 

 

actual grains per gallon hardness of your water supply.

 

 

See the Control section if a change in the setting is needed.

 

 

 

 

Grains of hardness in your

Water hardness can change over time, especially in well

 

water supply have increased

water. To check, have the water tested by a water analysis

 

 

laboratory or call your local water department. Adjust the

 

 

hardness number setting as needed.

14

Image 14
Contents GXSF23Z01 PNSF31Z01 GE Answer CenterOwner’s Manual Part No. 215C1002P002-4 Pub. No. 49-5800-4 3-98 CGTroubleshooting Tips Safety Instructions Operating Instructions Troubleshooting TipsCustomer Service Customer ServicePROPER INSTALLATION IMPORTANT SAFETY INFORMATION READ ALL INSTRUCTIONS BEFORE USINGSAFETY PRECAUTIONS Read and follow this Safety Information carefullyGXSF23Z Safety InstructionsTroubleshooting Tips Customer Service Amount of high capacity resin lbs/cu. ftAbout the water softener system Safety InstructionsService InstructionsSmartWater Softener System Control Settings RequiredOperating Instructions Set Present Time of DayFeature Program Memory ServiceFeature Optional Recharge Controls Feature/Service Automatic Electronic DiagnosticsTo remove an error code 1 Unplug transformer Service Control/Softener, Service Checkout ProcedureService Electronic Demand Time Features and Service If you do not find a problem with the visual checks, continue belowOperating Service Manually Initiated Electronic DiagnosticsOPEN A NEARBY SOFT WATER FAUCET Electronic Diagnostics Care and cleaning of the water softening systemService Manually Advanced Regeneration Check Checking the Salt Storage Level and RefillingCleaning Iron Out of the Water Softening System Sanitizing ProcedureClean the Nozzle and Venturi Assembly Care and cleaning of the water softener systemSafety Instructions tighten the cap or housingTroubleshooting Tips Before you call for service…Safety Instructions Operating Instructions Troubleshooting TipsWhat To Do ProblemPossible Causes No soft waterOperating Instructions Safety Instructions General Electric Company GE Service Protection PlusWarranty Registration Department P.O. Box Louisville, KY What BrandSerial Number Dear CustomerModel Number Consumer Product Ownership RegistrationGE Will Replace, At No Charge To You GE Water Softening System WarrantyCustomer Service What GE Will Not CoverService Contracts Service Telephone NumbersSpecial Needs Service Parts and Accessories