GE 6000A owner manual Cleaning the Nozzle and Venturi Assembly, About the water softener system

Page 14
Cleaning the Nozzle and Venturi Assembly

TroubleshootingTips Operating Instructions Installation Instructions SafetyInstructions

CustomerService

About the water softener system.

Cleaning the Nozzle and Venturi Assembly

A clean nozzle and venturi is needed for the water softening system to work properly. This small unit makes the suction to move brine from the salt storage area to the resin tank during regeneration. If it becomes plugged with sand, dirt, etc., the water softening system will not work and you will get hard water.

To get to the nozzle and venturi, remove the water softening system top cover. Be sure the water softening system is in service cycle (no water pressure at nozzle and venturi). Then, while holding the nozzle and venturi housing with one hand, remove the cap. Lift out the screen support and screen, then the nozzle and venturi. Wash and rinse the parts in warm water until clean. If needed, use a small brush to remove iron or dirt. Also check and clean the gasket.

NOTE: Some models have a small flow plug located in the nozzle and venturi, and/or a small cone shaped screen in the housing. Be sure to check and clean these parts, if your model is so equipped.

Carefully replace all parts in the correct order. Lightly lubricate the o-ring seal with clean silicone grease or petroleum jelly and place in position. Install and tighten the cap, by hand

only. Do not over-tighten the cap or housing.

Cap

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

O-ring seal

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Screen support

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Screen

 

 

 

 

 

 

 

 

 

Screen

 

 

 

 

 

 

 

 

 

Nozzle & Venturi

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Gasket

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

*Fill Flow plug

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Nozzle & Venturi housing

IMPORTANT: Be sure small holes in the gasket are centered directly over the small holes in the nozzle and venturi housing.

*Install with numbered side up, concave side down.

14

Image 14
Contents Part No. 215C1044P003-1 Pub. No. 49-50007-1 8-98 CG GE Answer CenterGXSS17Z01 Installation and Owner’s ManualCustomer Service CustomerServiceTroubleshooting Tips Installation InstructionsPROPER INSTALLATION IMPORTANT SAFETY INFORMATION READ ALL INSTRUCTIONS BEFORE USINGSAFETY PRECAUTIONS Read and follow this Safety Information carefullyUnpacking and Inspection Installation instructionsImportant Installation Recommendations See Where to Install the Softener section for more detailsWhere to Install the Softener Customer ServicePlan How You Will Install the Softener Tools and Materials Required for InstallationTroubleshootingTips SafetyInstructionsOperating Instructions Installation Instructions Typical Installation IllustrationFig. 3B Step-by-step installation instructionsFig. 3A Fig. 3Cinstallation for water leaks Fig. 4AInstall grounding clamps and wire 5 Connect and run the valve drain hoseInstructions Operating Instructions Troubleshooting Tips Customer ServiceSafety Instructions Installation 10 Connect to electrical powerProgram the Timer Solid State TimerCustomerService Set the timerSpecifications/Dimensions Safety Instructions Installation Instructions OperatingInstructions Troubleshooting Tips Automatic Hard Water Bypass During Regeneration ServiceAbout the water softener system FillBreaking a Salt Bridge bridgeCleaning the Nozzle and Venturi Assembly only. Do not over-tighten the cap or housingError Code About the face plate timer featuresTroubleshooting Tips What to do When a Power Outage OccursAbout regenerating the system Installation Instructions SafetyInstructionsSetting the Timer for Days and Fill Minutes of Regeneration TroubleshootingTips Operating InstructionsWater Hardness-Grains Per Gallon Regeneration ChartIf you need help to program the timer, all the GE Answer Center Pounds of Salt Used Each RegenerationPossible Causes Before you call for service…Problem What To DoGeneral Electric Company GE Service Protection PlusWarranty Registration Department P.O. Box Louisville, KY What BrandSerial Number Dear CustomerModel Number Consumer Product Ownership RegistrationParts list Customer ServiceParts catalog Parts list Customer Service Installation Instructions Troubleshooting TipsSafety Instructions Operating InstructionsTroubleshootingTips Operating InstructionsGE Will Replace, At No Charge To You GE Water Softening System WarrantySafety Instructions Installation Instructions What GE Will Not CoverService Contracts Service Telephone NumbersSpecial Needs Service Parts and Accessories