GE 6000A Step-by-step installation instructions, B, Customer Service, Install bypass valve

Page 7
Step-by-step installation instructions.

Step-by-step installation instructions.

Safety

Turn off the water supply to pipes to be cut and drain the house water pipes. Open both hot and cold faucets.

1 Install bypass valve:

Push the bypass valve (lubricate o-ring seals with silicone grease) into both ports of the valve as shown in Fig. 3A.

Snap the 2 large plastic clips in place, from the top, down as shown in Fig. 3A and Fig. 3B. Be sure they snap into place. Pull on the bypass valve to make sure it is held securely in place.

2 Move the softener assembly into installation position:

Be sure the installation surface is level and smooth. Sharp objects under the tank may puncture it. If needed, place the tank on a section of 3/4″ thick (minimum) plywood. Then, place shims under the plywood as needed to level the softener.

3 Plumb IN and OUT pipes to and from softener:

1 Install bypass valve: CAUTION: Observe all of the following cautions as you connect inlet and outlet plumbing.

Turn off the water heater.

Be sure incoming hard water supply is directed to the softener valve inlet port. If house water flow is from the left, use a plumbing cross-over as shown in Fig. 1.

If making a soldered copper installation, do all sweat soldering before connecting pipes to the bypass valve. Torch heat will damage plastic parts.

When turning threaded pipe fittings onto plastic fittings, use care not to cross-thread.

Use pipe joint compound on all external pipe threads.

Support inlet and outlet plumbing in some manner (use pipe hangers) to keep the weight off of the valve fittings.

4 Install the brine tank overflow fittings:

Insert the rubber grommet into the 3/4″ diameter hole in the brine tank sidewall as shown in Fig. 5.

Push the end of the hose adapter elbow into the grommet as shown in Fig. 5.

Fig. 3A.

Clip

 

Outlet

 

Inlet

 

 

 

 

 

 

O-ring seal goes into the outer groove

Bypass valve

NOTE: Threads on

only. The clip snaps into the inner

the valve are 1

groove (see below).

male pipe. If 1

 

 

 

 

 

 

pipe is needed, buy

 

 

 

adapters and plumb

 

 

 

to the 1threads.

 

 

 

 

Fig. 3B.

 

Clip

SIDE

END

VIEW

VIEW

 

3 Plumb IN and OUT pipes to and from softener: Bypass valve Valve body inlet or (push all the way in) outlet

Fig. 3C.

Turn bypass valve up- side down to connect to floor level plumbing

OUT

IN

Fig. 4.

 

Valve

Drain

drain

fitting on

hose

valve

 

Instructions Installation Instructions Operating Instructions Troubleshooting Tips

To sewer drain

7

Customer Service

Image 7
Contents Installation and Owner’s Manual GE Answer CenterGXSS17Z01 Part No. 215C1044P003-1 Pub. No. 49-50007-1 8-98 CGInstallation Instructions CustomerServiceTroubleshooting Tips Customer ServiceRead and follow this Safety Information carefully IMPORTANT SAFETY INFORMATION READ ALL INSTRUCTIONS BEFORE USINGSAFETY PRECAUTIONS PROPER INSTALLATIONSee Where to Install the Softener section for more details Installation instructionsImportant Installation Recommendations Unpacking and InspectionTools and Materials Required for Installation Customer ServicePlan How You Will Install the Softener Where to Install the SoftenerTypical Installation Illustration SafetyInstructionsOperating Instructions Installation Instructions TroubleshootingTipsFig. 3C Step-by-step installation instructionsFig. 3A Fig. 3B5 Connect and run the valve drain hose Fig. 4AInstall grounding clamps and wire installation for water leaks10 Connect to electrical power Troubleshooting Tips Customer ServiceSafety Instructions Installation Instructions Operating InstructionsSet the timer Solid State TimerCustomerService Program the TimerInstructions Troubleshooting Tips Safety Instructions Installation Instructions OperatingSpecifications/Dimensions Fill ServiceAbout the water softener system Automatic Hard Water Bypass During Regenerationbridge Breaking a Salt Bridgeonly. Do not over-tighten the cap or housing Cleaning the Nozzle and Venturi AssemblyWhat to do When a Power Outage Occurs About the face plate timer featuresTroubleshooting Tips Error CodeTroubleshootingTips Operating Instructions Installation Instructions SafetyInstructionsSetting the Timer for Days and Fill Minutes of Regeneration About regenerating the systemPounds of Salt Used Each Regeneration Regeneration ChartIf you need help to program the timer, all the GE Answer Center Water Hardness-Grains Per GallonWhat To Do Before you call for service…Problem Possible CausesWhat Brand GE Service Protection PlusWarranty Registration Department P.O. Box Louisville, KY General Electric CompanyConsumer Product Ownership Registration Dear CustomerModel Number Serial NumberCustomer Service Parts listParts catalog Parts list Parts catalog Operating Instructions Troubleshooting TipsSafety Instructions Installation InstructionsOperating Instructions TroubleshootingTipsWhat GE Will Not Cover GE Water Softening System WarrantySafety Instructions Installation Instructions GE Will Replace, At No Charge To YouParts and Accessories Service Telephone NumbersSpecial Needs Service Service Contracts