Kenmore 625.3847 Flow Control and Screen, To clean/replace flow control and screen FIG

Page 12

- CARE OF YOUR REVERSE OSMOSIS SYSTEM -

2.Press inward while turning the RO cap to the left

(_) to remove from the bracket/membrane housing.

3.Use a pliers, or heavy wire made into a hook, to

pull the RO cartridge from the housing.

Note: Sanitizing is recommended after servicing in- ner parts of the system (see page 9).

4. Install the new cartridge, end with o-ring seals in- ward. Work back and forth to get all the way in (end

of cartridge about 1-1/4" in from end of housing).

5.Lubricate the RO cap o- ring seal if dry. Replace the

o-ring into the cap. Press inward on the cap while turning to the right (_)to lock. The cap will not go on

if the RO cartridge is not fully seated inward.

6.Check the flow control and screen (see below).

7.Purge the RO membrane cartridge following instruc- tions on page 9.

5.Inspect the o-ring and collet. Replace if worn, cut

or otherwise damaged. Carefully replace into the drain port.

6.Be sure the flow control is in the end of the tubing, then push all the way into the fitting.

FIG. 10 ]

TO

 

DRAIN

 

A

flow (control) insert

l/4"tubi, ng _"1

]

_screen

o-ring seal Jdrain

FLOW CONTROL AND SCREEN

The flow control is vital for proper operation of the

RO membrane cartridge. The control keeps water

flow through the membrane at the needed rate to ob-

tain the best quality product water.

Whenever servicing the RO system, check the flow

control to be sure the small hole through it is clean

and unrestricted. Also check and clean or replace the

cone-shaped screen in front of the control. The RO

membrane cannot discharge minerals and impuri- ties to the drain if the flow control plugs with foreign

material. If this happens, it only takes a short time for

the membrane to foul and become useless.

To clean/replace flow control and screen (FIG. 10):

1.At the drain connection, depress the collet (FIG.

11)with a finger while carefully pulling on the drain tubing to remove.

2.Remove the flow control from the end of the drain tubing. Be sure the center hole is clean.

3.Check the drain tubing to be sure it's clean. Then insert the cleaned or new flow control into the tubing.

4.With a small screwdriver carefully remove the col- let and o-ring from the drain port. Use a small need-

le-nose pliers or tweezers to remove the screen from

the drain port. Thoroughly clean or replace with a

new screen. Install pointed end down.

Note: Visually check to be sure it is positioned cor- rectly.

ball

spring_ o-ring_

cap _check

,i valve

TUBING CONNECTION

(all push-in fitting locations)

This RO system includes push-in fittings for quick

tubing connection at most locations. If working with the fittings, do the following.

Connection (FIG. 11):

1.Use a sharp cutter or knife to cut the end of tubing square.

2.Inspect the end (about 1") of the tubing to be sure

there are no nicks, scratches or other rough spots. If

needed, cut the tubing again.

3.Push tubing through the collet and all the way into

fitting. Full engagement is 11/16" for 1/4" tubing, and 3/4" for 3/8" tubing.

continued

12

Image 12
Contents Reverse Osmosis Drinking Water System Safety Guides Full Warranty on Reverse Osmosis Drinking Water SystemTable of Contents Before YOU Begin to Install the RO SystemWhat Your Reverse Osmosis System will do Where to Install the RO System Steps to InstallTools and Materials Needed StepInstall Cold Water Supply Fitting Water Supply FittingCold water plumbing Install Drain Adapter Install FaucetPrepare Mounting Hole Guides to drill holes in porcelain or stainless steelAssemble Faucet 8blueRO System Install Storage TANK, Make Remaining Tubing Connections Connect Drain TUBING, Faucet toSANITIZING, Pressure Testing & Purging Pressure TestingSchematic HOW Your Reverse Osmosis System WorksReverse Osmosis Care of Your Reverse Osmosis System Prefilter and Post Filter CartridgesRO Membrane Cartridge To clean/replace flow control and screen FIG Flow Control and ScreenTubing Connection Connection FIGAutomatic Shutoff Service AssemblyShutoff Other Troubleshooting Problem CorrectionDimensions and Specifications Repair Parts 7208502 Remote RO Installation storage tank not shown Remote Location for Reverse Osmosis SystemPage Owners Manual Model no