Kenmore 625.3847 owner manual Install Storage TANK, Make Remaining Tubing Connections

Page 8

-STEP 5: INSTALL STORAGE TANK, MAKE REMAINING TUBING CONNECTIONS -

1. CONNECT DRAIN TUBING, FAUCET TO

DRAIN ADAPTER: Referring to FIG. 8, run the loose

section (connected to faucet barb fitting) of black

3 / 8" tubing from the faucet to the drain adapter, with

a black collet, installed on page 6. Cut this tubing as

needed to route in as straight of a run as possible,

without loops, dips, low spots or kinks. Cut the end of the tubing square. Then push all the way into the fitting. Pull on the tubing to be sure it's held firmly

in the adapter fitting. See pages 12 and 13 for tubing

connection instructions.

2. CONNECT TUBING TO WATER SUPPLY: Con- nect the feed (green) tube to the water supply fitting

installed on page 5. Connection to the fitting is as de-

scribed in Fig. 11, page 13.

3.Move the storage tankinto place next to the RO as-

sembly. You can stand the tank upright, or lay it on side. Apply no more than 2 wraps of Teflon tape to the threads on the nipple at the top of the tank. Hand

tighten the other included tubing adapter fitting

with the yellow collet onto the tank nipple, then

wrench 1/4 turn only. BE CAREFUL NOT TO CROSS THREAD.

4.Run the 3/8" yeUow tubing to the fitting installed in step 3. Be sure the end of the tubing is cut square, and insert all the way into the fitting. Again, pull on the tubing to be sure it's held firmly in the fitting.

TYPICAL UNDERSINK INSTALLATION

I FIG. 8 I

RO product water faucet

- 3/8" black tubing, to larger barb on faucet

water supply

Note: See note on page 4 regarding tubing lengths.

yellow collet

tubing adaptor

8

Image 8
Contents Reverse Osmosis Drinking Water System Safety Guides Full Warranty on Reverse Osmosis Drinking Water SystemWhat Your Reverse Osmosis System will do Table of ContentsBefore YOU Begin to Install the RO System Where to Install the RO System Steps to InstallTools and Materials Needed StepCold water plumbing Install Cold Water Supply FittingWater Supply Fitting Install Drain Adapter Install FaucetPrepare Mounting Hole Guides to drill holes in porcelain or stainless steelRO System Assemble Faucet8blue Install Storage TANK, Make Remaining Tubing Connections Connect Drain TUBING, Faucet toSANITIZING, Pressure Testing & Purging Pressure TestingReverse Osmosis SchematicHOW Your Reverse Osmosis System Works RO Membrane Cartridge Care of Your Reverse Osmosis SystemPrefilter and Post Filter Cartridges To clean/replace flow control and screen FIG Flow Control and ScreenTubing Connection Connection FIGShutoff Automatic Shutoff ServiceAssembly Other Troubleshooting Problem CorrectionDimensions and Specifications Repair Parts 7208502 Remote RO Installation storage tank not shown Remote Location for Reverse Osmosis SystemPage Owners Manual Model no