Kenmore 625.3486 owner manual 5A.TROUBLESHOOTING, Wiring Schematic, Faceplate

Page 20

SECTION 5

SERVICE TECH. INFORMATION

5A.TROUBLESHOOTING

Keep this manual with your water softener. If repairs are needed, the service technician must have the in-

formation on the following 8 pages. For telephone assistance, call toll free, 1-800-426-9345.

WIRING SCHEMATIC

BACK OF TIMER

 

(PWA)

<

Transformer

<

Turbine

E_

brn

_7

NC

Position

Sensor

 

 

 

 

grn

NO

Switch

 

 

 

 

 

FACEPLATE

High Flow

Sears Water Line

Deluxe Demand Water Softener

for Customer Assistance

 

1- 800- 426- 9345

with Dual Segment Electronic Display

 

ALWAYS MAKE THESE INITIAL CHECKS FIRST

1.Does the time display show the correct time of day?

--If display is blank, check power source to the soft-ener.

--If time is flashing, power was off for over 24

hours. The softener resumes normal operation

but regenerations occur at the wrong time.

--If an error code (Example: Err3) shows in the

faceplate display; go to AUTOMATIC ELEC-

TRONIC DIAGNOSTICS.

. Plumbing bypass valve(s) must be in full service position.

. The inlet and outlet pipes must connect to the softener inlet and outlet respectively.

. Is the transformer plugged into a "live",

grounded wall outlet, and the power cable

fastened securely?

. The valve drain hose must be free of kinks and

sharp bends, and not elevated over 8 ft. above the floor.

REMOVE THE TOP COVER AND SALT TANK

COVER

6.Is there salt in the storage tank?

7.Is the brine tubing connected? (See water flow diagrams).

8.Is the brine valve float set right? (See page 23).

. Press the SELECT button 2 times to display the

hardness setting. Be sure it is the correct setting

for the household's water supply. (Make a

hardness test of the raw water and compare with

the hardness setting. Also test a soft water

sample to verify if a problem exists.) Press the

SELECT button twice more to return to present time in the display.

If you do not find the problem after making initial

checks, do the MANUAL INITIATED ELECTRONIC

DIAGNOSTICS, and the MANUAL ADVANCE

REGENERATION CHECK.

20

Image 20
Contents Owners Manual Save this ManualWarranty Full ONE Year Warranty on Water SoftenerFull TEN Year Warranty Against Leaks Sears Installation Policy WarrantyContents ServiceRepair Parts Softener StartWater Softener START-UP Safety Guides SectionCheck List of ALL STEP-BY-STEPGUIDES to Install ValvePlastic Bypass ValvesWater Softener START-UP 1C.PROGRAM the Timer SET Present Time of DAYTimer ProgramGpg hardness 2ppmironx5=10+10 Times 30 Hardness Number SET Recharge Regeneration TimeWater Softener START-UP 1D. Sanitizing the Water Softener ADD WaterADD Salt Fill the Storage Tank with SaltWater Softening Salt with Iron Remov HOW Your Water Softener Works 2A.FACEPLATE Timer Features Extra RechargeRechargenow RechargetonightOptional SETTINGS- Clean Feature HOW Your Water Softener WorksWater Flow Through the Softener Program MemoryService Water Flow Through Softener in ServiceFill Backwash Brining Fast Rinse Brine RegenerationWater Flow Through Softener in Fast Rinse Water Flow Through the Softener in BackwashWater Flow Through Softener in Brining Brine Rinse Automatic Bypass ElectronicsBe Sure to Reset the Salt MONITOR, Please see page 9 for Salt Filling DirectionsSalt Bridge Salt BridgeCare of Your Softener 3B. Keeping the Water Softener Clean Cleaning Nozzle VenturiCovers Nozzle & VenturiKeep the Softener from Freezing Drain Water from SoftenerProblem Cause CorrectionOther Things to Know 4A.DIMENSIONS/SPECIFICATIONS Model no .348600 Timer HF Code HF31Bypass Valves SingleFaceplate 5A.TROUBLESHOOTINGWiring Schematic Troubleshooting Manual Initiated Electronics DiagnosticsDepending Valve position Following Indicators Show Display CAMCycle Flow Rates Gallons PER MIN 5A.TROUBLESHOOTINGManual Advance Regeneration Check 5B.ROTARY Valve Service DisassemblyAssembly Servicing the ValveService Cycle Fill CycleSwitch 5C. Water Flow Through the Softener ValveBrining and Brine Rinse Cycles Backwash CycleFast Rinse Cycle KEY PartNumber Description Cover Lock reqdfor shipment onlyBrine Valve Assembly INLET- Outlet Grounding ClampsCress-section Parts List KEY Part NO. NumberKEY Part NumberCall 7 am 7 pm, 7 days a week 800 366Call 24 hours a day, 7 days a week 800 473