SECTION 5
SERVICE TECH INFORMATION
5A.TROUBLESHOOTING
MANUAL ADVANCE REGENERATION CHECK
This check verifies proper operation of the valve motor, brine tank fill, brine draw, regeneration flow rates, and other controller functions. Always make the initial checks, and the manual initiated diagnostics.
NOTES: The faceplate display must show a steady
time (not flashing). If an error code shows, first
press the SELECT button to enter the diagnostic display.
1.Press the
flash (or clean backwash begins, if set) as the softener enters the fill cycle of regeneration. When FILL is on steady, remove the brinewell cover and, using a flashlight, observe fill water entering the tank.
*NOTE: If the CLEAN feature is set to ON, a
cleaning backwash (CLEAN and Bkwsh or Rinse flashes in the display, along with the minutes of the
clean cycle remaining), precedes the recharge.
a.If water does not enter the tank, look for an ob-
structed nozzle, venturi, fill flow plug, brine tubing, or brine valve riser pipe.
NOTE: If water system pressure is low, an elevated
drain hose may cause back pressure, stopping brine draw.
3. Again press
softener into backwash. Look for a fast flow of water from the drain hose.
at An obstructed flow indicates a plugged top dis- tributor, backwash flow plug, or drain hose.
t Press
into fast rinse. Again look for a fast drain flow.
Allow the softener to rinse for a few minutes to
flush out any brine that may remain in the resin
tank from the brining cycle test.
t To return the softener to service, press ON/
V__/Float
I Jz:q"- stop
III.,....,_ Float
CYCLE FLOW RATES (GALLONS PER MIN.)
FILL (flow to salt | storage tank) | 0.3 | (1.1 | liters) | |
BRINING | '_ | .16 | (.61 | liters) | |
BACKWASH | (flow to drain) | 1.8 | (6.8 | liters) | |
BRINE | RINSE | I | .12 | (.45 | liters) |
FAST | RINSE |
| 1.8 | (6.8 | liters) |
2.After observing fill, press the
shining a flashlight into the brinewell and observing a noticeable drop in the liquid level.
NOTE: Be sure a salt bridge is not preventing water with salt contact.
at If the softener does not draw brine...
... nozzle and/or venturi dirty or defective.
...nozzle and venturi not seated properly on gasket.
...restricted drain (check drain fitting and hose).
... defective nozzle and venturi seal.
...other inner valve defect (rotor seal, rotor &
disc, wave washer, etc.).
0,,
FREEBOARD MEASUREMENT
(Distance from top of resin tank, to top of resin bed.)
't
resin tank
FREEBOARD
lr
resin bed
23