Kenmore 425 owner manual Keeping the Water Softener Clean, Iron from Resin BED

Page 17

[i!i !! :i :_!! :i :_!! :;i SECTION 3

CARE OF YOUR WATER SOFTENER

B. KEEPING THE WATER SOFTENER CLEAN

NOZZLE & VENTURI

A clean nozzle and venturi (FIG. 11) is a must for the softener to work right. This small unit moves brine from the salt storage tank to the resin tank during re-

generation. If it becomes plugged with sand, silt,

dirt, etc., the softener will not work and you will get hard water.

To get to the nozzle and venturi, remove the softener top cover. Be sure the softener is in service cycle (no

water pressure at nozzle and venturi), then unscrew

the cap from the nozzle and venturi housing. Do not lose the large o-ring seal. Lift out the screen support

and screen, then the nozzle and venturi. Also check

and clean the gasket, flow plugs and screens. Wash and rinse the parts in warm water until clean. If needed, use a small brush to remove iron or dirt.

Carefully replace all parts in the correct order. Lu- bricate the o-ring seal with silicone grease or Vase-

line and place in position. Install and tighten the

cap, by hand only. Do not overtighten, which

may break the cap or housing.

IRON FROM RESIN BED

Your water softener takes hardness minerals (cal-

cium and magnesium) out of the water. Also, it can

control some "clear water" iron. See maximum al-

lowed in the specifications on page 4-1. With clear water iron, water from a faucet is clear when first put into a glass. After 15 to 30 minutes, the water be- gins to cloud or turn rust colored. A water softener WILL NOT remove any iron which makes the water cloudy or rusty as it comes from the faucet (called red water iron). To take red water iron out of water,

Cleaning Nozzle & Venturi

Cap -___..____._

O-ring Seal _

Screen Support _._._..

Screen _

Nozzle & Venturi _

Screen

Gasket _

tered directly over the small holes in the nozzle & venturi

housing.

*Flow Plug

(HVDC)

Nozzle & Venturi

Housing

*Install with numbered side up, concave

side down. Be sure the largest flow plug (with the largest hole) is located in the nozzle & venturi housing.

or over the maximum of clear water iron, an iron fil-

ter or other equipment is needed. Your local Sears store has trained people to help you with iron water problems.

If your water supply has clear water iron, even

though less than the maximum allowed, regular resin bed cleaning is needed. Your local Sears store has Water Softener Cleaner, Item No. 42-34426 for

this. Clean the bed at least every 6 months. If iron

shows up in the soft water before 6 months, clean

more often. Printed instructions are on the bottle.

3-2

Problems, Questions? Call 1- 800- 426- 9345 Kenmore Water Line

Image 17
Contents Save this Manual Owners ManualFull Three Year Electronics Warranty Full ONE Year Warranty on Water SoftenerFull TEN Year Warranty Against Leaks Sears Residential Water SoftenerWater Softener Start UP Care of Your Water SoftenerWater Softener Start UP Safety GuidesManual unless otherwise noted Check List of STEP-BY-STEP Guides to InstallSET Present Time of DAY Program the TimerDown SelectHardness Number SET Water Hardness NumberSET Recharge Regeneration Time KCICharge Sanitize the Water SoftenerWater Softening Salt with Iron Remov Adding Salt to the Storage TankSalt Monitor System Faceplate Timer FeaturesRecharge NOW Recharge TonightSRI5 I1 Tank Light Error CodeLI-I I1 Water Flow Through the SoftenerService Kenmores Ultra Cleansing FeatureRegeneration Soft Water Service and RegenerationRecharge Automatic BypassElectronics Salt Bridge Salt Adding Salt to Storage TANK, Salt BridgeIron from Resin BED Keeping the Water Softener CleanDrain All Water From Softener Protect the Water Softener from FreezingMemory Checklist ... to Help YOU Save MoneyProgram Timer HF Code HF36 Dimensions / SpecificationsModel NOS. Ultrasoft 425 & Ultrasoft Single BypassNSF/ANSI Pressure Drop PSI vs. Flow Rate GPMMake These Initial Checks First TroubleshootingElec TronicMost Likely Less Likely Manual Initiated Electronics DiagnosticsPossible Defect Code HF36 Brining Cycle Flow Rates Gallons PER MINBackwash Brine RinseDisassembly Rotary Valve ServiceAssembly Lieve PressureCycle Water Flow Through the Softener Valve Service CycleFill Backwash Cycle Fast Rinse Cycle Water Flow Through the Softener ValveRepair Parts for Water Softener Part Water Softener CompleteInlet Outlet Grounding Clamps Kenmore Model NOs .388460 I &625.388480Description Brine Valve AssemblyKEY Part XN14 Valve AssemblyBypass Installation Valve Valve AssemblyDescription NO. Number KEY Part Description NumberOwners Manual