Napoleon Fireplaces manual GENERAL MAINTENANCE NPS40 AND NPI40, Daily Whenever Using The Heater

Models: NPS40 NPI40

1 40
Download 40 pages 42.1 Kb
Page 25
Image 25
GENERAL MAINTENANCE NPS40 AND NPI40
W415-0616 / B / 02.18.08

25

GENERAL MAINTENANCE NPS40 AND NPI40

DAILY (WHENEVER USING THE HEATER)

OPEN MAIN VIEWING DOOR

!WARNING

The front of the heater becomes very hot during opera- tion. Let the heater cool completely before conducting service.

1.Open the side doors on either side of the heater.

Figure 35

2.On the right side of the heater are two latches. Release the latches by pulling the rear handle forward and dis- engaging the hook from the door frame. Swing open the viewing door.

INSPECT THE BURN POT

When burning, the fl ames should be bright orange with embers jumping from the burn pot.

Figure 37

CLEANING GLASS DOOR

If the glass is not kept clean, permanent discolouration and/or blemishes may result. If glass should ever crack, it must be replaced using 5mm thick ceramic glass available from your Napo- leon Dealer.

DO NOT SUBSTITUTE MATERIALS

DO NOT CLEAN GLASS WHEN HOT

DO NOT use abrasive cleaners to clean glass or plated parts.

DO NOT OPERATE THIS HEATER WITH THE GLASS DOOR OPEN

CLEANING THE HEAT EXCHANGE TUBES

Figure 36

DISPOSAL OF ASHES

Ashes should be placed in a metal container with a tight fi tting lid. The container should be placed on a non-combustible fl oor, well away from combustible materials, pending fi nal disposal. If ashes are disposed of by burial in soil or otherwise locally dispersed, they should be retained in the closed container until all cinders are thoroughly cooled.

!WARNING

The front edge of the hopper lid becomes very hot, do not touch the area below the handle.

Figure 40

!WARNING

This rod becomes very hot during operation. Wait till heat- er has cooled completely or you MUST wear heat resistant gloves when cleaning or handling this heater.

With the heater cool (or wearing heat resistant gloves), slide the heat exchange cleaner rod up and down several times to prevent the build up of ash on the heat exchange tubes.

Keep the viewing door closed so the fl y ash does not enter the room.

NOTE: More frequent cleaning may be required depending upon pellet quality.