Napoleon Fireplaces NPS40 manual NPI40 FINISHING, Flashing Installation, TRIVET NPI40

Models: NPS40 NPI40

1 40
Download 40 pages 42.1 Kb
Page 23
Image 23
NPI40 FINISHING

23

NPI40 FINISHING

FLASHING INSTALLATION

7. Slide the assembled

 

trim down over the

FIGURE 31

1.Secure the

Right Flashing

 

to the right

 

side of the

 

unit using two

 

of the #8 x

 

1/2" screws.

 

NOTE: Feed

 

the Air

 

Control Rod

 

into the Air

 

Control Slot

 

on the Right

 

Flashing

 

before securing.

AIR

(FIGURE 26)

 

CONTROL

 

ROD

 

AIR

 

CONTROL

 

SLOT

FIGURE 26

CONTROL

PANEL

RIGHT

FLASHING

L

 

O

1

W

2

3

4

H

5

 

IG

 

H

FLASHING INSTALLATION BURN

RATE LABEL

ashing. (FIGURE 31)

8. Affi x the logo to the bottom left hand corner

of the left fl ashing.TRIVET NPI40 TRIM

ASSEMBLY

TRIVET NPI40

The trivet for the NPI40 is attached by two set screws on the inside of the hopper lid.

2.Twist spring handle (supplied with the heater) onto the air control rod until it hits the stop.

3.Remove the two control panel securing screws, discard the screws and shipping bracket. (FIGURE 27)

4.Secure the control panel to the Right Flashing using the two #8 x 3/8" screws. (FIGURE

20) Secure the Left Flashing with the remaining #8 x 1/2" screws. (FIGURE 26)

3

2

2

3

4

1

1

4

5

 

 

5

SHIPPINGCONTROL

BRACKETPANEL

SECURINGSECURING SCREWS FIGURE 27 SCREWS

FIGURE 28

Figure 32

INSTALL VIEWING DOOR NPS40 AND NPI40

The main viewing door has been boxed separate from the heater, but MUST be installed

before burning the heater.

5.Align the holes

in the top of the Right and Left Flashing with those on the bottom lip of the Top Flashing and secure from the rear using the four #8-32 x 3/8" screws, washers and nuts. (FIGURE 29)

6.The three

pieces of trim are

 

assembled in the

 

same manner as

 

a picture frame. Place the corner

 

brackets (with screw loosened)

 

into the trim sections. Tighten the

 

screw spreading the two pieces

 

apart. Attach the adjoining section.

 

Repeat with the opposite side.

FIGURE 30

Tighten all screws fi rmly.

 

(FIGURE 30)

 

FIGURE 29

TOP

FLASHING

Figure 33

(Insert

Illustrated)

1.Open both side panels, exposing the bushing on the left and the latches on the right.

2.Align the pins on the door to the bushing on the left side of the heater. Lower into place until both bushings touch.

3.Engage the latch hooks into the door frame. Snap the rear

handle hook to lock the latch closed.

W415-0616 / B / 02.18.08

Page 23
Image 23